Rockwell-LGO

Rockwell Enclosed SMC Flex Controllers

Rockwell-Enclosed-SMC-Flex-Controllers-PRODUCT

Product Information

Enclosed SMC-3, SMC Flex, and SMC-50 Smart Motor Controllers

The enclosed SMC-3, SMC Flex, and SMC-50 Smart Motor Controllers are advanced motor control devices designed for efficient and reliable motor operation. They are suitable for controlling motors rated between 90A and 1250A. The controllers are available in
various configurations and can be customized using ProposalWorks software.

Catalog Number Explanation:

The catalog number provides information about the specific configuration of the controller. It consists of various codes that represent different parameters such as controller rating, enclosure type, input line voltage, control voltage, fuse clip/circuit breaker, pilot lights, options, and communication interfaces.

Controller Rating:

  • D10: 108A
  • D13: 135A
  • D20: 201A
  • D25: 251A
  • D31: 317A
  • D36: 361A
  • D48: 480A
  • D62: 625A
  • D78: 780A
  • D97: 970A
  • E12: 1250A

Enclosure Type:

  • J: 1/12/3R (3R)

Input Line Voltage:

  • H: 200-208V AC, 3-Phase, 50/60Hz
  • A: 230V AC, 3-Phase, 50/60Hz
  • B: 400-460V AC, 3-Phase, 50/60Hz
  • C: 500-575V AC, 3-Phase, 50/60Hz

Control Voltage:

  • D: 120V AC
  • J: 24V AC
  • A: 240V AC
  • EJ: 24V DC

Fuse Clip/Circuit Breaker (CB) – Combination Controllers Only:

  • J20: 200A, Class J
  • D12: 125A, CB
  • J40: 400A, Class J
  • D17: 175A, CB
  • J60: 600A, Class J
  • D25: 250A, CB
  • L80: 800A, Class L
  • D40: 400A, CB
  • L12: 1200A, Class L
  • D60: 600A, CB
  • L16: 1600A, Class L
  • D80: 800A, CB
  • D16: 160A, DIN
  • E12: 1200A, CB
  • D25: 250A, DIN
  • D40: 400A, DIN
  • D63: 630A, DIN
  • D80: 800A, DIN
  • N12: 1250A, DIN

Pilot Lights:

(1) Pilot Lights require configuration. See Table 8 for available options.

Options:

  • 6XP: 1 Factor Additional VA
  • 6YP: 2 Factor Additional VA
  • 8L: Line-Mounted Protective Module
  • 8M: Load-Mounted Protective Module
  • 8B: Line- and Load-Mounted Protective Modules
  • BP: Bypass Starter
  • NB: NEMA Bypass Starter
  • IC: Isolation Contactor
  • NI: NEMA Isolation Contactor
  • 989: 1 N.O 1 N.C Auxiliary Contact on Circuit Breaker or Fusible Disconnect Switch
  • HC3: SMC Flex Human Interface Module Door mounted type 4/12
  • 20S: Communication – RS-485
  • 20D: Communication – DeviceNet
  • 20E: Communication – Ethernet/IP
  • 20C: Communication – Control Net
  • 20P: Communication – ProfiBUS
  • PC: Pump Control
  • BC: Braking Control
  • TB10: 10 Spare Terminal Blocks
  • TB20: 20 Spare Terminal Blocks
  • P10: 100 mm Mounting foot, sheet metal
  • P20: 200 mm Mounting foot, sheet metal
  • F10: 100 mm Mounting foot, high-strength plastic
  • F20: 200 mm Mounting foot, high-strength plastic
  • 416: Plug-in Control Relay 2-pole
  • 417: Plug-in Control Relay On Delay
  • 418: Plug-in Control Relay Off Delay

Product Usage Instructions

To select the appropriate Smart Motor Controller configuration, please follow these steps:

  1. Use ProposalWorks software, available at http://www.rockwellautomation.com/global/e-tools/overview.page, to configure the Smart Motor Controller based on your specific requirements.
  2. Refer to the catalog number explanation to understand the codes and parameters associated with the controller.
  3. Choose the desired controller rating, enclosure type, input line voltage, control voltage, fuse clip/circuit breaker (for combination controllers), pilot lights (if required), and additional options as needed.
  4. Once you have determined the appropriate configuration, proceed with the installation and wiring of the Smart Motor Controller according to the provided installation instructions.
  5. Ensure that all electrical connections are made correctly and securely.
  6. Configure any pilot lights (if applicable) according to Table 8 in the user manual.
  7. Test the Smart Motor Controller to ensure proper functionality before operation.
  8. Refer to the user manual for additional information on specific features and troubleshooting guidelines.

For further assistance or technical support, please refer to the Rockwell Automation Publication 150-TD010A-EN-P – July 2018 or contact our customer support hotline.

Catalog Number Explanation

Examples given in this section are not intended to be used for product selection. Use ProposalWorks to configure Smart Motor Controllers. ProposalWorks is available from http://www.rockwellautomation.com/global/e-tools/overview.page.

Controllers Rated 90…1250 ARockwell-Enclosed-SMC-Flex-Controllers-FIG 1

a
Bulletin Number
Code Description
150F SMC Flex Non-combination
152F SMC Flex Combination with Fusible Disconnect
153F SMC Flex Combination with Circuit Breaker
b
Controller Rating [A]
Code Description
D10 108
D13 135
D20 201
D25 251
D31 317
D36 361
D48 480
D62 625
D78 780
D97 970
E12 1250
c
Enclosure Type
Code Description
J 1/12/3R (3R)
d
Input Line Voltage
Code Description
H 200…208V AC, 3-Phase,

50 /60 Hz

A 230V AC, 3-Phase, 50/

60 Hz

B 400…460V AC, 3-Phase,

50/60 Hz

C 500…575V AC, 3-Phase,

50/60 Hz

e
Control Voltage
Code Description
D 120V AC
J 24V AC
A 240V AC
EJ 24V DC
f
Fuse Clip/Circuit Breaker (CB)— Combination Controllers Only
Code Description Code Description
J20 200 A, Class J D12 125 A, CB
J40 400 A, Class J D17 175 A, CB
J60 600 A, Class J D25 250 A, CB
L80 800 A, Class L D40 400 A, CB
L12 1200 A, Class L D60 600 A, CB
L16 1600 A, Class L D80 800 A, CB
D16 160 A, DIN E12 1200 A, CB
D25 250 A, DIN
D40 400 A, DIN
D63 630 A, DIN
D80 800 A, DIN
N12 1250 A, DIN
g
Options
Code Description Code Description Code Description
1 Start-Stop Push-Button 6XP 1 Factor Additional VA 20C Communication: Control Net
1E On – Off Push-Button 6YP 2 Factor Additional VA 20P Communication: ProfiBUS
3 Hand-Off-Auto Selector Switch 8L Line-Mounted Protective Module PC Pump Control
3E On – Off Selector Switch 8M Load-Mounted Protective Module BC Braking Control
3H Hand-Auto Selector Switch 8B Line- and Load-Mounted Protective Modules TB10 10 Spare Terminal Blocks
3B SMC-Off-Bypass Selector Switch BP Bypass Starter TB20 20 Spare Terminal Blocks
13 Start-Stop Push-Button & Hand-Off-Auto Selector Switch NB NEMA Bypass Starter P10 100 mm Mounting foot, sheet metal
4_ _ _ _(1) Pilot Lights IC Isolation Contactor P20 200 mm Mounting foot, sheet metal
5_ _ _ _(1) Push to test Pilot Lights NI NEMA Isolation Contactor F10 100 mm Mounting foot, high- strength plastic
1XA Soft Stop Push Button 989 1 N.O 1 N.C Auxiliary Contact on Circuit Breaker or Fusible Disconnect Switch F20 200 mm Mounting foot, high- strength plastic
1XB Pump Stop Push Button HC3 SMC Flex Human Interface Module- Door mounted type 4/12 416 Plug-in Control Relay 2-pole
1XC Slow Speed Push Button 20S Communication: RS-485 417 Plug-in Control Relay On Delay
1XD Brake Push Button 20D Communication: DeviceNet 418 Plug-in Control Relay Off Delay
6P Control Circuit Transformer 20E Communication: Ethernet/IP

 

Documents / Resources

Rockwell Enclosed SMC Flex Controllers [pdf] Installation Guide
Enclosed SMC Flex Controllers, Enclosed, SMC Flex Controllers, Flex Controllers, Controllers

References

Leave a comment