The enclosed SMC-3, SMC Flex, and SMC-50 Smart Motor Controllers are advanced motor control devices designed for efficient and reliable motor operation. They are suitable for controlling motors rated between 90A and 1250A. The controllers are available in
various configurations and can be customized using ProposalWorks software.
Catalog Number Explanation:
The catalog number provides information about the specific configuration of the controller. It consists of various codes that represent different parameters such as controller rating, enclosure type, input line voltage, control voltage, fuse clip/circuit breaker, pilot lights, options, and communication interfaces.
Controller Rating:
- D10: 108A
- D13: 135A
- D20: 201A
- D25: 251A
- D31: 317A
- D36: 361A
- D48: 480A
- D62: 625A
- D78: 780A
- D97: 970A
- E12: 1250A
Enclosure Type:
- J: 1/12/3R (3R)
Input Line Voltage:
- H: 200-208V AC, 3-Phase, 50/60Hz
- A: 230V AC, 3-Phase, 50/60Hz
- B: 400-460V AC, 3-Phase, 50/60Hz
- C: 500-575V AC, 3-Phase, 50/60Hz
Control Voltage:
- D: 120V AC
- J: 24V AC
- A: 240V AC
- EJ: 24V DC
Fuse Clip/Circuit Breaker (CB) – Combination Controllers Only:
- J20: 200A, Class J
- D12: 125A, CB
- J40: 400A, Class J
- D17: 175A, CB
- J60: 600A, Class J
- D25: 250A, CB
- L80: 800A, Class L
- D40: 400A, CB
- L12: 1200A, Class L
- D60: 600A, CB
- L16: 1600A, Class L
- D80: 800A, CB
- D16: 160A, DIN
- E12: 1200A, CB
- D25: 250A, DIN
- D40: 400A, DIN
- D63: 630A, DIN
- D80: 800A, DIN
- N12: 1250A, DIN
Pilot Lights:
(1) Pilot Lights require configuration. See Table 8 for available options.
Options:
- 6XP: 1 Factor Additional VA
- 6YP: 2 Factor Additional VA
- 8L: Line-Mounted Protective Module
- 8M: Load-Mounted Protective Module
- 8B: Line- and Load-Mounted Protective Modules
- BP: Bypass Starter
- NB: NEMA Bypass Starter
- IC: Isolation Contactor
- NI: NEMA Isolation Contactor
- 989: 1 N.O 1 N.C Auxiliary Contact on Circuit Breaker or Fusible Disconnect Switch
- HC3: SMC Flex Human Interface Module Door mounted type 4/12
- 20S: Communication – RS-485
- 20D: Communication – DeviceNet
- 20E: Communication – Ethernet/IP
- 20C: Communication – Control Net
- 20P: Communication – ProfiBUS
- PC: Pump Control
- BC: Braking Control
- TB10: 10 Spare Terminal Blocks
- TB20: 20 Spare Terminal Blocks
- P10: 100 mm Mounting foot, sheet metal
- P20: 200 mm Mounting foot, sheet metal
- F10: 100 mm Mounting foot, high-strength plastic
- F20: 200 mm Mounting foot, high-strength plastic
- 416: Plug-in Control Relay 2-pole
- 417: Plug-in Control Relay On Delay
- 418: Plug-in Control Relay Off Delay
Product Usage Instructions
To select the appropriate Smart Motor Controller configuration, please follow these steps:
- Use ProposalWorks software, available at http://www.rockwellautomation.com/global/e-tools/overview.page, to configure the Smart Motor Controller based on your specific requirements.
- Refer to the catalog number explanation to understand the codes and parameters associated with the controller.
- Choose the desired controller rating, enclosure type, input line voltage, control voltage, fuse clip/circuit breaker (for combination controllers), pilot lights (if required), and additional options as needed.
- Once you have determined the appropriate configuration, proceed with the installation and wiring of the Smart Motor Controller according to the provided installation instructions.
- Ensure that all electrical connections are made correctly and securely.
- Configure any pilot lights (if applicable) according to Table 8 in the user manual.
- Test the Smart Motor Controller to ensure proper functionality before operation.
- Refer to the user manual for additional information on specific features and troubleshooting guidelines.
For further assistance or technical support, please refer to the Rockwell Automation Publication 150-TD010A-EN-P – July 2018 or contact our customer support hotline.
Catalog Number Explanation
Examples given in this section are not intended to be used for product selection. Use ProposalWorks to configure Smart Motor Controllers. ProposalWorks is available from http://www.rockwellautomation.com/global/e-tools/overview.page.
Controllers Rated 90…1250 A
a | |
Bulletin Number | |
Code | Description |
150F | SMC Flex Non-combination |
152F | SMC Flex Combination with Fusible Disconnect |
153F | SMC Flex Combination with Circuit Breaker |
b | |
Controller Rating [A] | |
Code | Description |
D10 | 108 |
D13 | 135 |
D20 | 201 |
D25 | 251 |
D31 | 317 |
D36 | 361 |
D48 | 480 |
D62 | 625 |
D78 | 780 |
D97 | 970 |
E12 | 1250 |
c | |
Enclosure Type | |
Code | Description |
J | 1/12/3R (3R) |
d | |
Input Line Voltage | |
Code | Description |
H | 200…208V AC, 3-Phase,
50 /60 Hz |
A | 230V AC, 3-Phase, 50/
60 Hz |
B | 400…460V AC, 3-Phase,
50/60 Hz |
C | 500…575V AC, 3-Phase,
50/60 Hz |
e | |
Control Voltage | |
Code | Description |
D | 120V AC |
J | 24V AC |
A | 240V AC |
EJ | 24V DC |
f | ||||
Fuse Clip/Circuit Breaker (CB)— Combination Controllers Only | ||||
Code | Description | Code | Description | |
J20 | 200 A, Class J | D12 | 125 A, CB | |
J40 | 400 A, Class J | D17 | 175 A, CB | |
J60 | 600 A, Class J | D25 | 250 A, CB | |
L80 | 800 A, Class L | D40 | 400 A, CB | |
L12 | 1200 A, Class L | D60 | 600 A, CB | |
L16 | 1600 A, Class L | D80 | 800 A, CB | |
D16 | 160 A, DIN | E12 | 1200 A, CB | |
D25 | 250 A, DIN | |||
D40 | 400 A, DIN | |||
D63 | 630 A, DIN | |||
D80 | 800 A, DIN | |||
N12 | 1250 A, DIN |
g | |||||||
Options | |||||||
Code | Description | Code | Description | Code | Description | ||
1 | Start-Stop Push-Button | 6XP | 1 Factor Additional VA | 20C | Communication: Control Net | ||
1E | On – Off Push-Button | 6YP | 2 Factor Additional VA | 20P | Communication: ProfiBUS | ||
3 | Hand-Off-Auto Selector Switch | 8L | Line-Mounted Protective Module | PC | Pump Control | ||
3E | On – Off Selector Switch | 8M | Load-Mounted Protective Module | BC | Braking Control | ||
3H | Hand-Auto Selector Switch | 8B | Line- and Load-Mounted Protective Modules | TB10 | 10 Spare Terminal Blocks | ||
3B | SMC-Off-Bypass Selector Switch | BP | Bypass Starter | TB20 | 20 Spare Terminal Blocks | ||
13 | Start-Stop Push-Button & Hand-Off-Auto Selector Switch | NB | NEMA Bypass Starter | P10 | 100 mm Mounting foot, sheet metal | ||
4_ _ _ _(1) | Pilot Lights | IC | Isolation Contactor | P20 | 200 mm Mounting foot, sheet metal | ||
5_ _ _ _(1) | Push to test Pilot Lights | NI | NEMA Isolation Contactor | F10 | 100 mm Mounting foot, high- strength plastic | ||
1XA | Soft Stop Push Button | 989 | 1 N.O 1 N.C Auxiliary Contact on Circuit Breaker or Fusible Disconnect Switch | F20 | 200 mm Mounting foot, high- strength plastic | ||
1XB | Pump Stop Push Button | HC3 | SMC Flex Human Interface Module- Door mounted type 4/12 | 416 | Plug-in Control Relay 2-pole | ||
1XC | Slow Speed Push Button | 20S | Communication: RS-485 | 417 | Plug-in Control Relay On Delay | ||
1XD | Brake Push Button | 20D | Communication: DeviceNet | 418 | Plug-in Control Relay Off Delay | ||
6P | Control Circuit Transformer | 20E | Communication: Ethernet/IP |