PV Current HS-PV5-MU Series Combiner Box Monitor 

PV Current HS-PV5-MU Series Combiner Box Monitor 

Important Information

All the pictures and product specifications are only for reference, because of the update of products and technology. There are differences between products and manual. Please contact us if you want to get more information about the product.

ATTENTION

Symbol WARNING!

This symbol shows an attention or a warning to remind the dangerous and safety. The hardware will be damaged if the user operate in a worry way.

Symbol NOTE!

This symbol shows an attention to make the product word well.

SAFETY INSTRUCTIONS

Please read this manual carefully before installation. If the product is damage with a wrong installation, we would not provide quality assurance.

Symbol WARNING:

Pease do all the operation and wiring professional with electrical technician or electrical engineer.

Symbol WARNING:

Please don’t touch other parts of the box when you install except the terminal.

Symbol WARNING:

All operation and wiring must conform to the requirements of the relevant standards!

Symbol WARNING:

Please cover the PV panel with the opaque material when you install.

Product introduction

HS-PV5-MU4/8/12/16/20/24, PV current combiner box monitor, is a product, which integrate the power supply, voltage acquisition, the current acquisition of PV string and acquisition of lightning arrester into one product. And it has the characteristic of small volume, no fan, wide temperature operation and high anti-interference. It adopt RS485 interface and support MODBUS protocol.
Product introduction

Model description

Model description

Introduction

  • Acquire the current of PV string, include 4/8/12/16/20/24 string;
  • Acquire the voltage of PV string, MAX DC 1500V;
  • Acquire the temperate of PV current combiner box;
  • Acquire the state of the lightning arrester
  • Acquire the state of the circuit breaker
  • Communication: RS485
  • Communication protocol: MODBUS
  • Communication baud rate: 2400,4800 9600
  • Communication address:1~100

Features

  • A wide input voltage rage, DC300~DC1500V
  • A flame-retardant shell
  • Acquire the isolated analog quantity
  • Acquire the isolated digital quantity
  • A wide temperature operation: -30~75℃
  • Easy matches
  • Matches a RF module to reduce wiring
  • Flexible installation mode
  • Easy disassembly

Technical parameters

Technical parameter table

Input
DC power inputDC300V~DC1500V
PV string current input4/8/12/16/20/24 branches, 0~25A, 0.5%
Interface
Communicate interfaceRS485
Digital quantity input3 ways, 2500V isolation
LED display8 bits
Operating Environment
Power≤3W
Operating temperature-30℃~+75℃
Storage temperature-40℃~+85℃
Relative humidity5℃~95℃ (No condensation)
Shape size
Length * width * heightHost unit:107mm*87mm*58mm
Acquisition unit: 72mm*42mm*39mm
Installation modeHost unit: DIN rail
Acquisition unit: DIN rail OR hang

Configuration software

The configuration software includes the following functions:

  • Modify the communication parameters of the product;
  • Record and analysis of real-time data;
  • Tele signalling alarm;
  • Set the alarm value

Parameter configuration interface:

Configuration software

Shape Size

  1. Host and acquisition unit (unit: mm)
    Shape Size
  2. Mounting plate:
    Shape Size

Interface Function

  1. Host unit
    NumberInterface definitionFunction
    15V5V +
    2G5V –
    3G0Switch acquisition G
    4D1Switch acquisition 1
    5D2Switch acquisition 2
    6D3Switch acquisition   3
    7KNC
    8CNC
    9BRS485 B
    10ARS485 A
    11G0RS485G
    12PPE
    PV+V+DC1500V +
    PV-V-DC1500V –

    Interface Function

  2. Acquisition unit:
    Interface Function
    NOTE: The connector can only be connected from the first acquisition unit.

Operating description

The man-machine interface includes: LED display, 3 button, PV string current input, and 3 indicator lights.
Operating description

  1. LED display and button:
    The LED display include: The value of the current ,voltage, power, baud rate, address, temperature, etc.
    The buttons include: up ,down and function key (F.K.).
  2. Indicator lights description:
    RUN: when this light gleamed, the monitor is normal running.
    RX: when this light is up, the monitor is receiving data.
    TX: when this light is up, the monitor is transmitting data.
  3. Button operating description:
    Operating description
    NOTE
    : Press up, can exit the setup when display a save.

The sequence of the button operation

  1. Wake up the LED display
  2. Enter a password: PASS **00
  3. Confirm the password: PASS **01
  4. Choose a address: Addr *100(1-100)
  5. Save the address: Addr SAVE
  6. Choose a baud rate: b3** 9600
  7. Save the baud rate: b*** SAVE
  8. Choose a channel number: Td** **16
  9. Save the channel number: Td** SAVE
  10. Choose special function: d*** 0000(reserve, cannot be modified)
  11. Save the special function: d*** SAVE
  12. Display the value of channel current(If the password is error, display the value of bus. If the password is right, display the value of channel.)
    Press up and down: Value of current: 01*- 00.00 –A
    Value of power: P*00 0000 –W
    Value of state: S**0 0000
    NOTE: The value of state correspond to the state of upper limit alarm, lower limit alarm, zero value alarm, reverse value alarm, unbalance alarm。
  13. Display the voltage: U**0 000.0
  14. Display the state of the voltage: S**0 0000
  15. Display the total power:UA00 0000 –W
  16. Display the electrical energy: E*00 0000 –KWh
  17. Display the state of digital quantity : S123 *000
  18. Display the acquisition mode: Ad** ***1(reserve, cannot be modified)
  19. Save the acquisition mode: SAVE ***1
  20. Display the temperature: Co* +/- 000.0 –℃
  21. Save the temperature: SAVE 000.0
  22. Exit the fixed display, begin the auto display.

Communication protocol

The communication protocol is MODBUS RTU. This protocol has a high data density, and a big throughput rate. The baud rate can choose to be 2400, 4800, 9600.

  1. Communication set description
    FormatContent
    ModeMODBUS RTU
    Baud rate9600(default)
    Data bits8 bits
    Parity check bitNo
    Stop bit1 bit
    Frame checkCRC16
  2. MODBUS function code description
    0x03 Read data command. Include channel current, voltage, and telecommunication.
    0x01 Read telecommunication command. Read telecommunication only.
  3. MODBUS message format description 0x03 function code description
    Request code format:
    DefinitionAddressFunction codeStart addressWordsCRC check
    DataADDR03HsREGnREGCRC16
    byte11222

    Response request code format:

    DefinitionAddressFunction codeResponse bytesResponse dataCRC check
    dataADDR03HXDATACRC16
    byte111X2

    0x01 function code description
    Request command code format:

    DefinitionAddressFunction codeStart addressWordsCRC check
    dataADDR01HsREGnREGCRC16
    byte11222

    Response request code format:

    DefinitionAddressFunction codeResponse bytesResponse dataCRC check
    dataADDR01HXDATACRC16
    byte111X2
  4. Address map and data:
    Word addresscontextWord lengthratio
    0x1000PV string channel current 110.01A
    0x1001PV string channel current 210.01 A
    0x1002PV string channel current 310.01 A
    0x1003PV string channel current 410.01 A
    0x1004PV string channel current 510.01 A
    0x1005PV string channel current 610.01 A
    0x1006PV string channel current 710.01 A
    0x1007PV string channel current 810.01 A
    0x1008PV string channel current 910.01 A
    0x1009PV string channel current 1010.01 A
    0x100APV string channel current 1110.01 A
    0x100BPV string channel current 1210.01 A
    0x100CPV string channel current 1310.01 A
    0x100DPV string channel current 1410.01 A
    0x100EPV string channel current 1510.01 A
    0x100FPV string channel current 1610.01 A
    0x1010PV string channel current 1710.01 A
    0x1011PV string channel current 1810.01 A
    0x1012PV string channel current 1910.01 A
    0x1013PV string channel current 2010.01 A
    0x1014PV string channel current 2110.01 A
    0x1015PV string channel current 2210.01 A
    0x1016PV string channel current 2310.01 A
    0x1017PV string channel current 2410.01 A
    0x1018Voltage10.1V
    0x1019Total current11A
    0x101ATemperature10.1℃
    0x101BTotal power (high first)21W
    0x101DChannel power 121W
    0x101FChannel power 221W
    0x1021Channel power 321W
    0x1023Channel power 421W
    0x1025Channel power 521W
    0x1027Channel power 621W
    0x1029Channel power 721W
    0x102BChannel power 821W
    0x102DChannel power 921W
    0x102FChannel power 1021W
    0x1031Channel power 1121W
    0x1033Channel power 1221W
    0x1035Channel power 1321W
    0x1037Channel power 1421W
    0x1039Channel power 1521W
    0x103BChannel power 1621W
    0x103DChannel power 1721W
    0x103FChannel power 1821W
    0x1041Channel power 1921W
    0x1043Channel power 2021W
    0x1045Channel power 2121W
    0x1047Channel power 2221W
    0x1049Channel power 2321W
    0x104BChannel power 2421W
    0x104D Tele signal 111
    0x104ETele signal 211
    0x104FTele signal 311
    0x1050Tele signal 411
    0x1051Tele signal 511
    0x1052Tele signal 611
    0x1053Tele signal 711
    0x1054Tele signal 811
    0x1055Tele signal 911
    0x1056Tele signal 1011
    0x1057Reserve
    0x1058Reserve

    NOTE!
    About the current of channel, voltage, temperature:
    The data format is 16 bits unsigned integer. (High bit first.)
    NOTE!
    About the temperature:
    0x101A the data format is 16bits complemented integer. (High bit first).Unit is ℃。For example, 0xff38 stand for -20℃.
    NOTE!
    About the Switch state:
    When the switch off, the switch state is 0, when the switch on, the switch state is 1.

  5. Telesignal address map:
    Register addressRegister content
    0x0100 PV string channel 1 current Zero value state
    0x0101PV string channel 1 current low value state
    0x0102PV string channel 1 current high value state
    0x0103PV string channel 2 current Zero value state
    0x0104PV string channel 2 current low value state
    0x0105PV string channel 2 current high value state
    0x0106PV string channel 3 current Zero value state
    0x0107PV string channel 3 current low value state
    0x0108PV string channel 3 current high value state
    0x0109PV string channel 4 current Zero value state
    0x010APV string channel 4 current low value state
    0x010BPV string channel 4 current high value state
    0x010CPV string channel 5 current Zero value state
    0x010DPV string channel 5 current low value state
    0x010EPV string channel 5 current high value state
    0x010FReserve
    0x0110PV string channel 6 current Zero value state
    0x0111PV string channel 6 current low value state
    0x0112PV string channel 6 current high value state
    0x0113PV string channel 7 current Zero value state
    0x0114PV string channel 7 current low value state
    0x0115PV string channel 7 current high value state
    0x0116PV string channel 8 current Zero value state
    0x0117PV string channel 8 current low value state
    0x0118PV string channel 8 current high value state
    0x0119PV string channel 9 current Zero value state
    0x011APV string channel 9 current low value state
    0x011BPV string channel 9 current high value state
    0x011CPV string channel 10 current Zero value state
    0x011DPV string channel 10 current low value state
    0x011EPV string channel 10 current high value state
    0x011FReserve
    0x0120PV string channel 11 current Zero value state
    0x0121PV string channel 11 current low value state
    0x0122PV string channel 11 current high value state
    0x0123PV string channel 12 current Zero value state
    0x0124PV string channel 12 current low value state
    0x0125PV string channel 12 current high value state
    0x0126PV string channel 13 current Zero value state
    0x0127PV string channel 13 current low value state
    0x0128PV string channel 13 current high value state
    0x0129PV string channel 14 current Zero value state
    0x012APV string channel 14 current low value state
    0x012BPV string G channel 14 current high value state
    0x012CPV string channel 15 current Zero value state
    0x012DPV string channel 15 current low value state
    0x012EPV string channel 15 current high value state
    0x012FReserve
    0x0130PV string channel 16 current Zero value state
    0x0131PV string channel 16 current low value state
    0x0132PV string channel 16 current high value state
    0x0133PV string channel 17 current Zero value state
    0x0134PV string channel 17 current low value state
    0x0135PV string channel 17 current high value state
    0x0136PV string channel 18 current Zero value state
    0x0137PV string channel 18 current low value state
    0x0138PV string channel 18 current high value state
    0x0139PV string channel 19 current Zero value state
    0x013APV string channel 19 current low value state
    0x013BPV string channel 19 current high value state
    0x013CPV string channel 20 current Zero value state
    0x013DPV string channel 20 current low value state
    0x013EPV string channel 20 current high value state
    0x013FReserve
    0x0140PV string channel 21 current Zero value state
    0x0141PV string channel 21 current low value state
    0x0142PV string channel 21 current high value state
    0x0143PV string channel 22 current Zero value state
    0x0144PV string channel 22 current low value state
    0x0145PV string channel 22 current high value state
    0x0146PV string channel 23 current Zero value state
    0x0147PV string channel 23 current low value state
    0x0148PV string channel 23 current high value state
    0x0149PV string channel 24 current Zero value state
    0x014APV string channel 24 current low value state
    0x014BPV string channel 24 current high value state
    0x014CReserve
    0x014DReserve
    0x014EReserve
    0x014FReserve
    0x0150Voltage low value/high value state
    0x0151Reserve
    0x0152Reserve
    0x0153Reserve
    0x0154Reserve
    0x0155Reserve
    0x0156Reserve
    0x0157Reserve
    0x0158Switch 1 state
    0x0159Switch 2 state
    0x015ASwitch 3 state
    0x015BReserve
    0x015CReserve
    0x015DReserve
    0x015EReserve
    0x015FReserve
    0x0160PV string channel 24 current reverse alarm
    0x0161PV string channel 23 current reverse alarm
    0x0162PV string channel 22 current reverse alarm
    0x0163PV string channel 21 current reverse alarm
    0x0164PV string channel 20 current reverse alarm
    0x0165PV string channel 19 current reverse alarm
    0x0166PV string channel 18 current reverse alarm
    0x0167PV string channel 17 current reverse alarm
    0x0168PV string channel 16 current reverse alarm
    0x0169PV string channel 15 current reverse alarm
    0x016APV string channel 14 current reverse alarm
    0x016BPV string channel 13 current reverse alarm
    0x016CPV string channel 12 current reverse alarm
    0x016DPV string channel 11 current reverse alarm
    0x016EPV string channel 10 current reverse alarm
    0x016FPV string channel 9 current reverse alarm
    0x0170PV string channel 8 current reverse alarm
    0x0171PV string channel 7 current reverse alarm
    0x0172PV string channel 6 current reverse alarm
    0x0173PV string channel 5 current reverse alarm
    0x0174PV string channel 4 current reverse alarm
    0x0175PV string channel 3 current reverse alarm
    0x0176PV string channel 2 current reverse alarm
    0x0177PV string channel 1 current reverse alarm
    0x0178Reserve
    0x0179Reserve
    0x017AReserve
    0x017BReserve
    0x017CReserve
    0x017DReserve
    0x017EReserve
    0x017FReserve
    0x0180PV string channel 24 current unbalance alarm
    0x0181PV string channel 23 current unbalance alarm
    0x0182PV string channel 22 current unbalance alarm
    0x0183PV string channel 21 current unbalance alarm
    0x0184PV string channel 20 current unbalance alarm
    0x0185PV string channel 19 current unbalance alarm
    0x0186PV string channel 18 current unbalance alarm
    0x0187PV string channel 17 current unbalance alarm
    0x0188PV string channel 16 current unbalance alarm
    0x0189PV string channel 15 current unbalance alarm
    0x018APV string channel 14 current unbalance alarm
    0x018BPV string channel 13 current unbalance alarm
    0x018CPV string channel 12 current unbalance alarm
    0x018DPV string channel 11 current unbalance alarm
    0x018EPV string channel 10 current unbalance alarm
    0x018FPV string channel 9 current unbalance alarm
    0x0190PV string channel 8 current unbalance alarm
    0x0191PV string channel 7 current unbalance alarm
    0x0192PV string channel 6 current unbalance alarm
    0x0193PV string channel 5 current unbalance alarm
    0x0194PV string channel 4 current unbalance alarm
    0x0195PV string channel 3 current unbalance alarm
    0x0196PV string channel 2 current unbalance alarm
    0x0197PV string channel 1 current unbalance alarm
    0x0198Reserve
    0x0199Reserve
    0x019AReserve
    0x019BReserve
    0x019CReserve
    0x019DReserve
    0x019EReserve
    0x019FReserve
  6. 0x104D definition:
    Bit0 PV string channel 1 current Zero value state
    Bit1 PV string channel 1 current low value state
    Bit2 PV string channel 1 current high value state
    Bit3 PV string channel 2 current Zero value state
    Bit4 PV string channel 2 current low value state
    Bit5 PV string channel 2 current high value state
    Bit6 PV string channel 3 current Zero value state
    Bit7 PV string channel 3 current low value state
    Bit8 PV string channel 3 current high value state
    Bit9 PV string channel 4 current Zero value state
    Bit10 PV string channel 4 current low value state
    Bit11 PV string channel 4 current high value state
    Bit12 PV string channel 5 current Zero value state
    Bit13 PV string channel 5 current low value state
    Bit14 PV string channel 5 current high value state
    Bit15 reserve
  7. 0x104E definition:
    Bit0 PV string channel 6 current Zero value state
    Bit1 PV string channel 6 current low value state
    Bit2 PV string channel 6 current high value state
    Bit3 PV string channel 7 current Zero value state
    Bit4 PV string channel 7 current low value state
    Bit5 PV string channel 7 current high value state
    Bit6 PV string channel 8 current Zero value state
    Bit7 PV string channel 8 current low value state
    Bit8 PV string channel 8 current high value state
    Bit9 PV string channel 9 current Zero value state
    Bit10 PV string channel 9 current low value state
    Bit11 PV string channel 9 current high value state
    Bit12 PV string channel 10 current Zero value state
    Bit13 PV string channel 10 current low value state
    Bit14 PV string channel 10 current high value state
    Bit15 reserve
  8. 0x104F definition:
    Bit0 PV string channel 11 current Zero value state
    Bit1 PV string channel 11 current low value state
    Bit2 PV string channel 11 current high value state
    Bit3 PV string channel 12 current Zero value state
    Bit4 PV string channel 12 current low value state
    Bit5 PV string channel 12 current high value state
    Bit6 PV string channel 13 current Zero value state
    Bit7 PV string channel 13 current low value state
    Bit8 PV string channel 13 current high value state
    Bit9 PV string channel 14 current Zero value state
    Bit10 PV string channel 14 current low value state
    Bit11 PV string channel 14 current high value state
    Bit12 PV string channel 15 current Zero value state
    Bit13 PV string channel 15 current low value state
    Bit14 PV string channel 15 current high value state
    Bit15 reserve
  9. 0x1050 definition:
    Bit0 PV string channel 16 current Zero value state
    Bit1 PV string channel 16 current low value state
    Bit2 PV string channel 16 current high value state
    Bit3 PV string channel 17 current Zero value state
    Bit4 PV string channel 17 current low value state
    Bit5 PV string channel 17 current high value state
    Bit6 PV string channel 18 current Zero value state
    Bit7 PV string channel 18 current low value state
    Bit8 PV string channel 18 current high value state
    Bit9 PV string channel 19 current Zero value state
    Bit10 PV string channel 19 current low value state
    Bit11 PV string channel 19 current high value state
    Bit12 PV string channel 20 current Zero value state
    Bit13 PV string channel 20 current low value state
    Bit14 PV string channel 20 current high value state
    Bit15 reserve
  10. 0x1051 definition:
    Bit0 PV string channel 21 current Zero value state
    Bit1 PV string channel 21 current low value state
    Bit2 PV string channel 21 current high value state
    Bit3 PV string channel 22 current Zero value state
    Bit4 PV string channel 22 current low value state
    Bit5 PV string channel 22 current high value state
    Bit6 PV string channel 23 current Zero value state
    Bit7 PV string channel 23 current low value state
    Bit8 PV string channel 23 current high value state
    Bit9 PV string channel 24 current Zero value state
    Bit10 PV string channel 24 current low value state
    Bit11 PV string channel 24 current high value state
    Bit12 Reserve
    Bit13 Reserve
    Bit14 Reserve
    Bit15 Reserve
  11. 0x1052 definition:
    Bit0 Voltage low value/high value state
    Bit1 Reserve
    Bit2 Reserve
    Bit3 Reserve
    Bit4 Reserve
    Bit5 Reserve
    Bit6 Reserve
    Bit7 Reserve
    Bit8 Switch 1 state
    Bit9 Switch 2 state
    Bit10 Switch 3 state
    Bit11 Reserve
    Bit12 Reserve
    Bit13 Reserve
    Bit14 Reserve
    Bit15 Reserve
  12. 0x1053 definition:
    Bit0 PV string channel 24 current reverse alarm
    Bit1 PV string channel 23 current reverse alarm
    Bit2 PV string channel 22 current reverse alarm
    Bit3 PV string channel 21 current reverse alarm
    Bit4 PV string channel 20 current reverse alarm
    Bit5 PV string channel 19 current reverse alarm
    Bit6 PV string channel 18 current reverse alarm
    Bit7 PV string channel 17 current reverse alarm
    Bit8 PV string channel 16 current reverse alarm
    Bit9 PV string channel 15 current reverse alarm
    Bit10 PV string channel 14 current reverse alarm
    Bit11 PV string channel 13 current reverse alarm
    Bit12 PV string channel 12 current reverse alarm
    Bit13 PV string channel 11 current reverse alarm
    Bit14 PV string channel 10 current reverse alarm
    Bit15 PV string channel 9 current reverse alarm
  13. 0x1054 definition:
    Bit0 PV string channel 8 current reverse alarm
    Bit1 PV string channel 7 current reverse alarm
    Bit2 PV string channel 6 current reverse alarm
    Bit3 PV string channel 5 current reverse alarm
    Bit4 PV string channel 4 current reverse alarm
    Bit5 PV string channel 3 current reverse alarm
    Bit6 PV string channel 2 current reverse alarm
    Bit7 PV string channel 1 current reverse alarm
    Bit8 Reserve
    Bit9 Reserve
    Bit10 Reserve
    Bit11 Reserve
    Bit12 Reserve
    Bit13 Reserve
    Bit14 Reserve
    Bit15 Reserve
  14. 0x1055 definition:
    Bit0 PV string channel 24 current unbalance alarm
    Bit1 PV string channel 23 current unbalance alarm
    Bit2 PV string channel 22 current unbalance alarm
    Bit3 PV string channel 21 current unbalance alarm
    Bit4 PV string channel 20 current unbalance alarm
    Bit5 PV string channel 19 current unbalance alarm
    Bit6 PV string channel 18 current unbalance alarm
    Bit7 PV string channel 17 current unbalance alarm
    Bit8 PV string channel 16 current unbalance alarm
    Bit9 PV string channel 15 current unbalance alarm
    Bit10 PV string channel 14 current unbalance alarm
    Bit11 PV string channel 13 current unbalance alarm
    Bit12 PV string channel 12 current unbalance alarm
    Bit13 PV string channel 11 current unbalance alarm
    Bit14 PV string channel 10 current unbalance alarm
    Bit15 PV string channel 9 current unbalance alarm
  15. 0x1056 definition:
    Bit0 PV string channel 8 current unbalance alarm
    Bit1 PV string channel 7 current unbalance alarm
    Bit2 PV string channel 6 current unbalance alarm
    Bit3 PV string channel 5 current unbalance alarm
    Bit4 PV string channel 4 current unbalance alarm
    Bit5 PV string channel 3 current unbalance alarm
    Bit6 PV string channel 2 current unbalance alarm
    Bit7 PV string channel 1 current unbalance alarm
    Bit8 Reserve
    Bit9 Reserve
    Bit10 Reserve
    Bit11 Reserve
    Bit12 Reserve
    Bit13 Reserve
    Bit14 Reserve
    Bit15 Reserve

Packaging and shipping

Packing: The product is packaged by carton. The content includes: a PV current combiner box monitor, a instructions, a certificate.
Transport: No severe vibration and impact in transportation.
Preservation: Place in a well ventilated place, and avoid high temperature. Avoid rain and snow invasion.

Quality Assurance

Warranty period:12 months.

Please take care of the invoice. It will be need in warranty period.

Quality guarantee note:

  • We will repair or replace the product for free in the quality guarantee period.
  • The substandard products should return to us after replace.
  • The customer shall give us reasonable time to repair.

We have right to refuse quality assurance under the following situation:

  • Damage in transport
  • Incorrect installation
  • Incorrect modification
  • Incorrect use
  • Harsh environment
  • Use the product out of the rang or beyond the relevant standard
  • Man-made destruction

Safety operation at the scene

Please operate follow this step before your inspection to ensure your safety.

  1. turn-off the circuit breaker.
  2. turn-off the fuse seat.

Symbol WARNING:

All the terminals of the DC circuit breaker are still charged when the circuit breaker is turned off. All the terminals of the fuse seats are still charged when the fuse seats are turned off. Make sure the circuit breaker and fuse seats are all turned off when you work!