The Composite Temperature + Humidity Controller is a device that controls temperature and humidity using RTD Pt100, 3-wire for temperature measurement and DC Linear (Voltage) for humidity measurement. The device comes with a brief operation manual that provides quick reference to wiring connections and parameter searching. For more details on operation and application, the users can visit www.ppiindia.net. The device is manufactured by PPI India and can be contacted at 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar – 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net.

Product Usage Instructions

The Composite Temperature + Humidity Controller comes with various utility parameters, temperature parameters, relative humidity (% RH) parameters, OP3 function parameters, supervisory parameters, and compressor operation & power indication parameters. The users can refer to the respective pages in the manual for detailed information on these parameters.

To use the device, follow the below steps:

  1. Connect the RTD Pt100, 3-wire for temperature measurement and DC Linear (Voltage) for humidity measurement to the device as per the wiring connections mentioned in the manual.
  2. Configure the utility parameters using the PAGE-33 section of the manual. The users can set the compressor control strategy, zero offset for temperature value, and range for low and high temperature values.
  3. Configure the temperature parameters using the PAGE-10 section of the manual. The users can set alarm-1 band, alarm-1 hysteresis, proportional band, integral time, derivative time, and cycle time.
  4. Configure the relative humidity (% RH) parameters using the PAGE-11 section of the manual. The users can set alarm-2 band, alarm-2 hysteresis, proportional band, integral time, derivative time, and cycle time.
  5. Configure the OP3 function parameters using the PAGE-13 section of the manual. The users can set output-3 function selection, compressor setpoint, compressor hysteresis, and compressor time delay.
  6. Configure the supervisory parameters using the PAGE-12 section of the manual. The users can enable/disable SP adjustment on PAGE-0, self-tune command, and baud rate.
  7. Configure the compressor operation & power indication parameters using the PAGE-1 section of the manual. The users can set compressor operation mode, output power for temperature loop, and output power for %RH loop.

Note: The users can refer to TABLE-1 in the manual for RH input configuration. The device is calibrated for 0 to 5 VDC input for % RH. However, the transmitter output signal may be any voltage between 0 to 5 VDC. The users can use the formulae mentioned in TABLE-1 to compute the range low and range high values for RH input configuration.

PARAMETERS

UTILITY PARAMETERSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 1

TEMPERATURE PARAMETERSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 2

RELATIVE HUMIDITY (% RH) PARAMETERSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 3PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 4

OP3 FUNCTION PARAMETERSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 5

SUPERVISORY PARAMETERSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 6PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 7

COMPRESSOR OPERATION & POWER INDICATIONPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 8

TABLE-1 RH INPUT CONFIGURATION

The controller is calibrated for 0 to 5 VDC input for % RH. The transmitter output signal, however, may be any voltage between 0 to 5 VDC (For e.g. 0 to 1 VDC,1 to 3.6 VDC, 0 to 3.3 VDC etc.). The value for ‘Range Low’ and ‘Range High’ parameters must be corresponding to 0 and 5 VDC only. For this, use the following formulae for computing the ‘Range Low’ and ‘Range High’ values.PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 9

(where; Span = Signal High – Signal Low)PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 10

FRONT PANEL LAYOUT

Front PanelPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 11

Keys OperationPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 12

PV Error Indications For Dry Bulb
Temperature (Upper Readout)PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 13

PV Error Indications For Relative
Humidity (RH) (Lower Readout)PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 14

ELECTRICAL CONNECTIONSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 15

ENCLOSURE ASSEMBLYPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 16

JUMPER SETTINGS

OUTPUT-3PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 17 PPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 18

MOUNTING DETAILS

OUTPUT-3 MODULEPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 19

SERIAL COMM. MODULEPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 20

RH SENSORSPPI RTD-Pt100-Self-Tune-PID-Temperature-Controller-fig 21

This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net

  • 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar – 401 210.
  • Sales : 8208199048 / 8208141446
  • Support : 07498799226 / 08767395333
  • E: sales@ppiindia.net
  • support@ppiindia.net

Documents / Resources

PPI RTD Pt100 Self Tune PID Temperature Controller [pdf] Instruction Manual
RTD Pt100 Self Tune PID Temperature Controller, RTD Pt100, Self Tune PID Temperature Controller, PID Temperature Controller, Temperature Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *