INKBIRD ITC-306A WIFI Temperature Controller User Manual
ITC-306A WIFI
Part 1 Quick Guide to Use
01 CAUTION
- KEEP CHILDREN AWAY
- TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS
- RISK OF ELECTRIC SHOCK. DO NOT PLUG INTO ANOTHER RELOCATABLE
POWER TAPS OR AN EXTENSION CORD - USE ONLY IN DRY LOCATION
ATTENTION:
02 Product Features
- Plug and play, easy to use
- Dual relay controlling, one for control output, another for abnormal protection
- Support Celsius and Fahrenheit reading
- Dual display window for simultaneous display of measured temperature and stop heating temperature
- Dual temperature probes to ensure the accuracy of the water temperature
- Temperature calibration
- High and low temperature alarm
- Probe abnormal alarm
- Continuous heating time alarm
03 Technical Parameters
- Model: ITC-306A
- Brand name: INKBIRD
- Input: 230Vac 50Hz IOA/2300WMAX
- output: 230V ac 50Hz IOA/2300W (total two receptacles) MAX
- Disconnection means: Type 1 B
- Pollution degree: 2
- Rated impulse voltage: 2500V
- Automatic action: 30000 cycles
- Type of temperature probe: R256C-10Knt1% ROC-26.74—27.B3Kn
- Temperature control range: 0.06C-45.OV32.O’F-113’F
- Temperature measurement range: 40. CC—I OffC/-40.00F—21TF
- Temperature display accuracy: O. 1 1
- Temperature measurement accuracy: FIG 1 Technical Parameters
- Display unit: Celsius oc or Fahrenheit OF
- Ambient temperature:
- Storage environment:
Temperature: OOC-600C/320F-1400F;
Humidity: (Umfrozen or condensation state) - Warranty: Controller 2 years, probe 1 year
04 Technical Assistance and Warranty
4.1 Technical Assistance
If you have any problems installing or using this controller, please refer to the instruction manual for guidance. If you require further assistance, please email us at support@inkbird.com. We will reply within 24 hours, Monday to Saturday. Alternatively, you can visit our official website (www.inkbird.com) to find answers to common technical questions.
4.2 Warranty
INKBIRD TECH CO„ LTD warrants this controller (one year for the temperature probe) against defects caused by INKBlRD’s workmanship or materials for two years (one year for the temperature probe) from the date of purchase, provided it is operated under normal conditions by the original purchaser (not transferable). This warranty is limited to the repair or replacement (at INKBlRD’s discretion) of all or part of the controller.
Part 2
01 Control Panel
02 INKBIRD APP Setting
2.1 Download the APP
Search the keyword ” INKBIRD ” in Appstore or Google Play, or scan the following QR code to download and install the APP.
2.2 Pair with your phone
6) Open the app, it will ask you to register or log in your account on the APP.
Select the country and enter your email to finish the registration. Then press “Add Home” button to create your home.
Add device in quick connection:
- Plug the device in the socket and make sure that the device is in the Smartconfig.
- Configuration state (the LED symbol is flashing, interval flashing 250ms). Click “Confirm indicator rapidly blink” and then select Wi-Fi network, enter Wi-Fi password, click “confirm” to enter connection process.
- The device only supports 2.4GHz Wi-Fi router.
Add device in AP mode:
- Plug the device in the socket and make sure that the device is in the AP Configuration State (the LED symbol is flashing slowly, interval flashing 1500ms).
- Click “Confirm indicator slowly blink” and then select Wi-Fi network, enter Wi-Fi password, click “confirm” to enter connection process.
- Press “Connect now” and it will go to your WLAN Setting in your smart phone, select the “SmartLife-XXXX” to directly connect to the router without putting in password.
- Go back to app to enter into the automatic connection interface.
03 Controlling Function Description
3.1 Button Description
3.2 Menu Setting Flow Chart
3.3 Changing Settings
3.4 Control Function Description
When the controller is working normally, the controller will automatically select the smaller temperature value of the two settings TSI and TS2 to start the heating, and will stop heating when the temperature reach the larger one (the minimum absolute value of TSI and TS2 is 0.3 oc or 0.50F), PV displays the current temperature measurement value, and the SV displays the temperature at which heating stops.
3.5 High/Low Temperature Alarm (AH, AL)
When measured temperature zthe setting value of high temperature AH, it will alarm and turn off heating output. The screen will rotate to current temperature, buzzer will “bi-bi-Biii”, until the temperature AH, buzzer will be off and return to normal display and control. Or press any button to only turn the buzzer alarm off.
When measured temperature the setting value of low temperature AL, it will alarm. The screen will rotate to display” AL “and current temperature, buzzer will “bi-bi-Biii”, until the temperature AL, buzzer will be off and return to normal display and control. Or press any button to only turn the buzzer alarm off.
High and low temperature alarm will be pushed to mobile APP and remind the customer that the product is in alarm state.
3.6 Continuous Heating Time Alarm (CT)
When measured temperature the starting heating temperature, the output control is turned on. If the continuous heating time arrives, but the measured temperature has not risen to the stop heating temperature, at this time the heater is abnormal or the probe is abnormal, and the output is forcibly tumed off. PV will show E5, the buzzer keeps ringing, and the alarm status is pushed to the mobile APP to remind the customer that the product is in an alarm state and need to check in time.
When CT O, it means that the continuous heating alarm function has been cancelled.
3.7 Temperature Correction (CA)
When the measured temperature deviates from the standard temperature, the temperature calibration function can be used to calibrate the measured value consistent with the standard value. The calibrated temperature : the measured temperature value + the calibration value.
3.8 Fahrenheit or Celsius Seting (CF)
Support setting Fahrenheit or Celsius. The default temperature unit is Fahrenheit. If you need to display the unit in Celsius, please set the CF to C and note that when the CF is changed , all setting values will be restored to the default setting and the buzzer will beep once.
04 Abnormal Situation
4.1 Abnormal Temperature
The temperature difference between the two temperature probes is greater than or equal to 30C/50F
4.2 Probe Abnormal
Either the probe is not plugged in properly,or there is a short circuit inside or inside the probe.
Note:
When the product is abnormal, the PV will show as follows:
Er: Both probes have problems at the same time
El or E2: Temperature Probe Abnormal
E4: The temperature difference between the two temperature probes is greater than or equal to 30C/5.00F
E5: Continuous Heating Time Alarm
05 APP
06 FCC Requirement
changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
07 IC Warning
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1 )This device may not cause interference.
(2)This device must accept any interference, including interference that may cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 andcompliance with RSS-102
RF exposure, users can obtain Canadian information on RF exposure and compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
08 Troubleshooting Guide
Shenzhen Inkbird Technology Co., Ltd.
support@inkbird.com
Consignor: Shenzhen Inkbird Technology Co., Ltd.
Office Address: Room 1803, Guowei Building, No.68 Guowei Road,
Xianhu Community, Liantang, Luohu District, Shenzhen, China
Manufacturer: Shenzhen Lerway Technology Co., Ltd.
Factory Address: Room 501, Building 138, No. 71, Yiqing Road, Xianhu
Community, Liantang Street, Luohu District, Shenzhen, China
Read More About This Manual & Download PDF:
Documents / Resources
![]() | INKBIRD ITC-306A WIFI Temperature Controller [pdf] User Manual 306A, 2AYZD-306A, 2AYZD306A, ITC-306A WIFI Temperature Controller, ITC-306A WIFI, Temperature Controller, Controller |