Model:MERC-1100/1300W-PHUAWEI MERC 1300W-P Smart Module Controller

MERC-1300W-P Smart Module Controller

HUAWEI MERC 1300W-P Smart Module Controller - Higher YieldsHUAWEI MERC 1300W-P Smart Module Controller - Flexible DesignHUAWEI MERC 1300W-P Smart Module Controller - Active SafetyHUAWEI MERC 1300W-P Smart Module Controller - Smart O&M
Higher Yields
Module-level Optimization
Increases System Energy Yield by 5% to 30%
Flexible Design
Long String Design to
Reduce Bos
Active Safety
Firefighting and O&M Safety with Modulelevel Rapid Shutdown
Smart O&M Pinpointing OpenCircuit Fault for Quick Troubleshooting

HUAWEI MERC 1300W-P Smart Module Controller - Symbol MERC-1100/1300W-P

Technical Specification

Technical Specification                                1100W-P   MERC-1300W-P
Input
Rated input DC power 11100 W1300 W
Absolute max. input voltage125 V
MPPT operating voltage range12.5–105 V
Max. short-circuit current (Isc)20 A
Max. efficiency99.5%
Weighted efficiency99.0%
Overvoltage categoryII
Output
Max. output voltage80 V
Max. output current22 A
Output bypass 2Yes
Safety output voltage 31 V
Standards Compliance
SafetyIEC62109-1 (class II safety)
RoHSYes
General Specification
Dimensions (W X H X D)149 mm x 104 mm x 48.8 mm (5.9 in. x 4.1 in. x 1.9 in.)
Weight (including wires)1.0 kg (2.2 lb.)
Installation kit (optional)PV Module Frame Plate/T-shaped Bolt 4
Input connectorStaubli MC4
Input wire length0.1 m (+/-) (short-input-cable version) 5
Output connectorStaubli MC4
Output wire length0.1 m (+), 5.1 m (-) (short-input-cable version) 5
Operating temperature–40°C to +85°C 6
Relative humidity0%–100%
IP ratingIP68
Compatible invertersSUN2000-12-25K-MB0, SUN2000-12-25KTL-M5, SUN2000-30-40KTL-M3, SUN2000-50KTL-M3, SUN5000-150K-MG0
PV System Design 7/8/9SUN2000- 12~25K-MB0SUN2000- 12~25KTL-M5SUN2000- 30~40KTL-M3SUN2000- 50KTL-M3SUN5000-150K-MG0
Min. string length (power optimizers)888812
Max. string length (power optimizers)2525252020
Max. DC power per string20,000 W20,000 W20,000 W20,000 W20,000 W

HUAWEI MERC 1300W-P Smart Module Controller - DC power

  1. The maximum power of PV module at STC shall NOT exceed the “Rated input DC power” of MERC-1100/1300W-P. PV Modules with up to ±10% power tolerance are allowed.
  2. Any power optimizer, which is connected to an operating inverter in a PV string, will be bypassed when it fails.
  3. When the MERC-1100/1300W-P is disconnected from inverter or when the inverter is off, its output voltage will become 1 V.
  4. It is for PV module frame/extruded aluminum profile racking system installation.
  5. Pay attention to the PV module wire length. To match PV modules with a split junction box and short output wire, the long-input-cable version (input wire: 1.3 m (+/-); output
    wire: 0.1m (+)/2.9m (-)) of MERC-1100/1300W-P is available upon request.
  6. When the operating temperature of the MERC-1100/1300W-P reaches 70 °C to 85 °C, it may shut down due to over-temperature protection and report an over-temperature alarm.
    After the temperature decreases, it can automatically resume working without causing any damage.
  7. Each PV module under the same inverter must be equipped with a MERC-1100/1300W-P.
  8. 8SUN2000-450W-P2/600W-P and MERC-1100/1300W-P can NOT be used in mixture under the same Smart Energy/PV Controller.
  9. It is recommended that strings under the same inverter have an equal capacity. If this is not feasible, the capacity difference between strings under the same inverter must not
    exceed 2 kW. Otherwise, the energy yield will be reduced.

Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.