Honeywell-logo

Honeywell E-Mon MMU 25 Meter Configuration

Honeywell-E-Mon-MMU-25-Meter-Configuration-product

Specifications:

  • Product Name: E-Mon MMU 25 Meter
  • Model Number: MMU 25
  • Max Number of Meters: 25
  • Tag Characters: Up to eleven characters per meter

Product Usage Instructions

  1. Position the E-Mon MMU 25 Meter in the desired location.
  2. Assign a unique Tag to each meter using the provided spaces.
  3. Ensure proper alignment of the meters for accurate readings.
  4. For detailed configuration steps, refer to the user manual.
  5. For any assistance, contact customer support at 800-334-3666 or visit www.hwll.co/e-mon.

FEATURES

  • Available in configurations containing up to 8, 16, or 25 meters.
  • MMU cabinets may contain E-Mon ® Class 1000, Class 2000 (kWh or kWh/demand), Class 3200, Green Class Meters and Class 6000.
  • Compact installation of multiple meters allows for easy and centralized reading.
  • Three-phase MMU cabinets come with prewired voltage feeds.
  • For Class 1000, Class 2000, Class 3200, and Green Class Meters, IDRs (Interval Data Recorders) can be factory installed inside MMU enclosures along with meters.
  • Allows for easy interface with E-Mon Energy software system
  • The connections from the meters to the IDR are prewired at the factory.
  • Class 1000, Class 2000, Class 3200 and Green Class meters MMU cabinets may contain meters of different voltage configurations. (i.e. 208V & 480V meters inside a single MMU enclosure.)
  • Class 6000 meters, uses the same meter for both 208V and 480V applications.

MMU Dimensions (Class 1000, Class 2000, Class 3200, and Green Class meters)

NOTE: Not suitable for outdoor installations.

Honeywell-E-Mon-MMU-25-Meter-Configuration-fig- (1)

Dimensions (in inches)

MMUABC
MMU824121-1/4
MMU1624203
MMU2530243

Meter Configuration

MMUAcrossDownTotal Meter Spaces
MMU8248
MMU164416
MMU244 or 54 or 524

MODEL NUMBERS
When ordering, specify configuration, meters to be contained inside cabinet, and blank spaces (if any).

Class 3400 Example:

  • 1 MMU8
  • 6 E32-208200-MRTUKIT
  • 1 E32-480400-MRTUKIT
  • 1 Blank Spaces

Available Configurations:

  • MMU8
  • MMU16
  • MMU24

MMU Dimensions (Class 6000)

NOTE: NEMA 4x certified enclosure

Honeywell-E-Mon-MMU-25-Meter-Configuration-fig- (2)

MMU Dimensions and Meter Configuration

MMUABCAcrossDownTotal Meter Spaces
MMU824163/4248
MMU1630303/44416
MMU2436363/46424

Home and Building Technologies

® U.S. Registered Trademark

© 2020 Honeywell International Inc. 38-00077—XX M.S. 01-19 Printed in United States

For more information please call or visit 800-334-3666www.hwll.co/e-mon

FAQ

Q: What is the maximum number of meters that can be configured with the E-Mon MMU 25 Meter?
A: The E-Mon MMU 25 Meter allows configuration for up to 25 meters.

Q: Can I assign a unique Tag to each meter?
A: Yes, you can assign a Tag of up to eleven characters to each meter at no additional cost.

Q: How can I get more information or assistance?
A: For more information or assistance, please contact customer support at 800-334-3666 or visit www.hwll.co/e-mon.

Documents / Resources

Honeywell E-Mon MMU 25 Meter Configuration [pdf] Owner's Manual
E-Mon MMU 25 Meter Configuration, E-Mon, MMU 25 Meter Configuration, 25 Meter Configuration, Configuration

References