Honeywell E-Mon MMU 25 Meter Configuration
Specifications:
- Product Name: E-Mon MMU 25 Meter
- Model Number: MMU 25
- Max Number of Meters: 25
- Tag Characters: Up to eleven characters per meter
Product Usage Instructions
- Position the E-Mon MMU 25 Meter in the desired location.
- Assign a unique Tag to each meter using the provided spaces.
- Ensure proper alignment of the meters for accurate readings.
- For detailed configuration steps, refer to the user manual.
- For any assistance, contact customer support at 800-334-3666 or visit www.hwll.co/e-mon.
FEATURES
- Available in configurations containing up to 8, 16, or 25 meters.
- MMU cabinets may contain E-Mon ® Class 1000, Class 2000 (kWh or kWh/demand), Class 3200, Green Class Meters and Class 6000.
- Compact installation of multiple meters allows for easy and centralized reading.
- Three-phase MMU cabinets come with prewired voltage feeds.
- For Class 1000, Class 2000, Class 3200, and Green Class Meters, IDRs (Interval Data Recorders) can be factory installed inside MMU enclosures along with meters.
- Allows for easy interface with E-Mon Energy software system
- The connections from the meters to the IDR are prewired at the factory.
- Class 1000, Class 2000, Class 3200 and Green Class meters MMU cabinets may contain meters of different voltage configurations. (i.e. 208V & 480V meters inside a single MMU enclosure.)
- Class 6000 meters, uses the same meter for both 208V and 480V applications.
MMU Dimensions (Class 1000, Class 2000, Class 3200, and Green Class meters)
NOTE: Not suitable for outdoor installations.
Dimensions (in inches)
MMU | A | B | C |
---|---|---|---|
MMU8 | 24 | 12 | 1-1/4 |
MMU16 | 24 | 20 | 3 |
MMU25 | 30 | 24 | 3 |
Meter Configuration
MMU | Across | Down | Total Meter Spaces |
---|---|---|---|
MMU8 | 2 | 4 | 8 |
MMU16 | 4 | 4 | 16 |
MMU24 | 4 or 5 | 4 or 5 | 24 |
MODEL NUMBERS
When ordering, specify configuration, meters to be contained inside cabinet, and blank spaces (if any).
Class 3400 Example:
- 1 MMU8
- 6 E32-208200-MRTUKIT
- 1 E32-480400-MRTUKIT
- 1 Blank Spaces
Available Configurations:
- MMU8
- MMU16
- MMU24
MMU Dimensions (Class 6000)
NOTE: NEMA 4x certified enclosure
MMU Dimensions and Meter Configuration
MMU | A | B | C | Across | Down | Total Meter Spaces |
---|---|---|---|---|---|---|
MMU8 | 24 | 16 | 3/4 | 2 | 4 | 8 |
MMU16 | 30 | 30 | 3/4 | 4 | 4 | 16 |
MMU24 | 36 | 36 | 3/4 | 6 | 4 | 24 |
Home and Building Technologies
- In the U.S.: Honeywell E-Mon 715 Peachtree Street NE Atlanta, GA 30308
- customer.honeywell.com
® U.S. Registered Trademark
© 2020 Honeywell International Inc. 38-00077—XX M.S. 01-19 Printed in United States
For more information please call or visit 800-334-3666 – www.hwll.co/e-mon
FAQ
Q: What is the maximum number of meters that can be configured with the E-Mon MMU 25 Meter?
A: The E-Mon MMU 25 Meter allows configuration for up to 25 meters.
Q: Can I assign a unique Tag to each meter?
A: Yes, you can assign a Tag of up to eleven characters to each meter at no additional cost.
Q: How can I get more information or assistance?
A: For more information or assistance, please contact customer support at 800-334-3666 or visit www.hwll.co/e-mon.
Documents / Resources
![]() | Honeywell E-Mon MMU 25 Meter Configuration [pdf] Owner's Manual E-Mon MMU 25 Meter Configuration, E-Mon, MMU 25 Meter Configuration, 25 Meter Configuration, Configuration |