DMP - LOGO7381 ITI™
Interface Module
INSTALLATION AND PROGRAMMING GUIDE

DMP 738A and 738I ITI Interface Module

ABOUT THE 738I ITI™

The 738I ITI™ Wireless Interface Module allows you to interface ITI™ SuperBus™ 2000 Series Wireless receivers with the DMP  T30/XT50 Series and XR150/XR550 Series panels. This module allows up to 96 supervised, programmable zones of ITI wireless transmitters when used with the ITI™ MAX SuperBus™ 2000 Radio Receiver. The 738I allows 32 zones when used with the ITI™ 32- one SuperBus™ 2000 Radio Receiver and allows 16 zones when used with the ITI™ 16-Zone SuperBus™ 2000 Radio Receiver. Tables 1
and 2 list compatible wireless receivers and transmitters.

Supported Wireless Receivers and Transmitters
The maximum wire distance between the ITI wireless receiver and the 738I is 3 feet. Table 1 lists the wireless receivers supported and  Table 2 lists the wireless transmitters supported.

 

MODEL NAME

NUMBER OF SUPPORTED ZONES
XT30XT50

XR150/XR550

16-Zone SuperBus™ 2000 Radio Receiver161616
32-Zone SuperBus™ 2000 Radio Receiver163232
MAX SuperBus™ 2000 Radio Receiver163296

Table 1: ITI Wireless Receivers Supported

MODEL NAME

ITI MODEL NUMBER

2-Button SAW Keychain Touchpad60-707-0195R
4-Button SAW Keychain Touchpad•60-659-95R
2-Button Crystal Keyfob60-607-319.5
4-Button Crystal Keyfob”60-606-319.5
SAW Door/Window Sensor60-670-95R
Crystal Standard Door/ Window Sensor60-362-10-319.5
Crystal Long-Life Door/ Window Sensor60-641-95
Recessed Micro Door/Window Sensor60-741-95
Crystal PIR Motion Sensor60-703-95

MODEL NAME

ITI MODEL NUMBER

SAW PIR Motion Sensor60-639-95R
Wireless AP750W PIR Motion Sensor60-880-95
SAW Pet Immune PIR Motion Sensor60-807-95R
DS 924i Pet Immune PIR Motion Sensor60-511-02-95
SAW Outdoor PIR Motion Sensor60-639-95R-OD
Water-Resistant Pendant Panic Sensor60-578-10-95
Wrist Watch Panic Sensor60-906-95
Wireless ShatterPron. Glassbreak Sensor60-873-95
Learn Mode DS 924i PIR Motion Sensor60-511-01-95

Table 2: ITI Wireless Transmitters Supported

DMP 738A and 738I ITI Interface Module - FIG 1 Note: During 738I programming, the keyfob can be assigned to one zone that operates only the top two buttons by selecting Arming zone, style Maintain. After programming is complete, the Lock button enables a maintained Short condition that arms the assigned area(s).  The Unlock button restores the zone to a Normal condition that disarms the assigned area(s).

INSTALL THE 738I ITI™

Mount the Module
Mount on Wall
The module comes in a case that mounts directly to walls, backboards, or other flat surfaces. Wire entrances are on the back and on each side of the case. Two screw holes at the bottom of the case are for mounting the case on single-gang switch boxes or rings.
Mount in Enclosure
The module can be mounted in a DMP enclosure using the standard 3-hole mounting pattern. Refer to Figure 1 as needed during installation.

  1. Hold the plastic standoffs against the inside of the enclosure sidewall.
  2. Insert the included Phillips head screws from the outside of the enclosure into the standoffs. Tighten the screws.
  3. Carefully snap the module onto the standoffs.

Figure 1: Standoff and Module Installation

DMP 738A and 738I ITI Interface Module - FIG

2 Wire the Module
The 738I connects to the panel 4-wire keypad data bus of XT30/XT50 Series panels and panel 4-wire keypad data bus and the LX-Bus™  of XR150/XR550 Series panels. Use a 4-wire harness to easily connect the 738I to an ITI Wireless Receiver.
DMP 738A and 738I ITI Interface Module - FIG 1 Note: When programming 738I zones on the LX-Bus of an XR150/XR550 Series panel, select NO when prompted whether the zone is wireless.
DMP Bus Header
For connection to a keypad bus, connect the provided Model 300 4-wire harness (with one 4-wire connector) from the DMP BUS header to the panel terminals marked Red (7), Yellow (8), Green (9), and Black (10).
For connection to the LX-Bus, connect the provided Model 300 4-wire harness from the DMP BUS header to the four wires of the LX-Bus.
Receiver Header
Connect the provided Model 300 4-wire harness from the RECEIVER header to the ITI wireless receiver.
Red = +12
Green = B
Yellow = A
Black = GND
PROG Header
When programming the 738I, connect the provided Model 330 programming cable (with two 4-wire connectors) from the PROG header to any DMP Thinline, wireless, or graphic touchscreen keypad.
PROGRAM Header
1. Place the provided jumper across the PROGRAM header to enter 738I programming mode.
2. After programming, remove the jumper from the header and place it over one pin for future use.

Figure 2: 738I Connection
DMP 738A and 738I ITI Interface Module - FIG 2

PROGRAM THE 738I ITI™

  1. Connect the Model 330 Programming Cable from the PROG header to any DMP Thinline or graphic touchscreen keypad set to address 1. Refer to the specific keypad installation sheet for information on changing the keypad address.
  2. Place the jumper across the PROGRAM header. The 738I immediately enters programming mode.
  3. Press the CMD key to continue.
    DMP 738A and 738I ITI Interface Module - FIG 1Note: While in programming mode, all 738I communication to the panel stops.

DMP 738A and 738I ITI Interface Module - FIG 3

Initialization
Press the Select key under YES to reset all programming options to the factory default. Press the Select key under NO to maintain all programming options at their current settings.

DMP 738A and 738I ITI Interface Module - FIG 4

Panel Bus Type
Press the Select key under KYPD when connecting the 738I to the panel keypad bus. Press the Select key under LX when connecting the  738I to the panel LX-Bus. Press the CMD key to accept the selection. An asterisk appears to the left of the bus type selected.

DMP 738A and 738I ITI Interface Module - FIG 5

Zone Number
Enter the two-character zone number (01 – 96) to be programmed. If the zone number is less than 10, enter a leading zero, such as 01.  Refer to Table 3 for Keypad Bus Zone numbers. Press CMD to accept the entry.
For LX-Bus Zone Numbers, enter the right two digits of the zone number. The panel automatically enters the hundreds of digits representing the LX-Bus slot where the card is installed. See Tables 4 and 5. Press CMD to accept the entry.

Table 3: ITI Wireless Receivers Supported

KEYPAD ADDRESS

ZONE NUMBERS

XT30/XT50XR150/XR550
111 to 1411 to 14
221 to 2421 to 24
331 to 3431 to 34
441 to 4441 to 44
5N/A51 to 54
6N/A61 to 64
7N/A71 to 74
8N/A81 to 84
DMP 738A and 738I ITI Interface Module - FIG 1 Note: XR550 Series panels support 16 addresses. 738I only supports 8 addresses.

Table 4: LX-Bus Zone Numbers

LX-BUS ZONE NUMBERS
 

738I ZONE

XR150 SERIES

XR550 SERIES

LX-BUS

500

LX-BUS

500

LX-BUS

600

LX-BUS

700

LX-BUS

800

LX-BUS

900

1501501601701801901
2502502602702802902
3503503603703803903
4504504604704804904
16516516616716816916
17517517617717817917
32532532632732832932
33533533633733833933
44544544644744844944
45545545645745845945

Table 5: LX-Bus Zone Numbers Continued

LX-BUS ZONE NUMBERS

 

738I ZONE

XR150 SERIES

XR550 SERIES

LX-BUS

500

LX-BUS

500

LX-BUS

600

LX-BUS

700

LX-BUS

800

LX-BUS

900

57557557657757857957
58558558658758858958
66566566666766866966
67567567667767867967
78578578678778878978
79579579679779879979
81581581681781881981
82582582682782882982
95595595695795895995
96596596696796896996

DMP 738A and 738I ITI Interface Module - FIG 6

Transmitter Type
Enter a transmitter type by pressing the Select keys below the type of transmitter used as shown on the LCD. For example, press the third from the left Select key to choose unsupervised. Refer to the installation instructions provided with the ITI transmitter for additional information. Default is UN. An asterisk appears to the left of the transmitter type chosen. Press the CMD key to accept the selection.
UN = Unused Zone
RF = Supervised Transmitter
UR = Unsupervised Transmitter
When a wireless transmitter reed switch, contact, or button is in a faulted condition, then the corresponding panel zone is shorted. When a  wireless transmitter tamper is in a faulted condition, the corresponding panel zone is open. A supervised transmitter must report to the  738I at least once every 30 hours or that zone is indicated as missing to the DMP panel.

DMP 738A and 738I ITI Interface Module - FIG 7

Transmit Now
This is the transmitter learning to function and the message displays until the learn function completes. You must trip the transmitter tamper by removing the cover. This sends a transmitter identification to the 738I, identifying the device. The 738I stores the identification and learns the transmitter.DMP 738A and 738I ITI Interface Module - FIG 8

Already Zone
This indicates that the transmitter has previously been learned as a zone. This message continuously displays until the Back Arrow or CMD key is pressed. When the Back Arrow key is pressed, programming returns to TRANSMIT NOW to allow a different transmitter to be learned.  When the CMD key is pressed, programming returns to the ZONE number. (xx = zone number)

DMP 738A and 738I ITI Interface Module - FIG 9

External Contact
Select the type of external contact the transmitter is using. Press the Select key under NC for a Normally Closed circuit. Press the Select key under NO for a Normally Open circuit. Press the Select key under UN if an external contact is not used on this transmitter. An asterisk appears next to the currently selected option.

Exit Programming
Remove the jumper from the PROGRAM header to exit the 738I programming mode. Place the jumper over one pin for future use.  Remove the Model 330 cable and the 32-character keypad from the PROG header. After exiting programming mode, all zone states report to the panel as NORMAL. Test and verify all zones for proper communication.
738I LED Operation
The green LED on the 738I Module indicates data transmission to the panel.
On: There are no transmitters programmed.
Off: The 738I is not being programmed, or the 738I is not responding to the panel.
Flashes: The 738I is transmitting data to the panel, or it is being programmed.

COMPATIBILITY

XT30/XT50 Series Panels
XR150/XR550 Series Panels

PRODUCT SPECIFICATIONS

Primary Power
Current Draw
Zones
Dimensions
12 VDC
42 mA
5 VDC, 2 mA max
4.5” W x 2.75” H x 1.75” D 11.43 W x 7 H x 4.45 D cm

CERTIFICATIONS

FCC Part 15

Information furnished is believed to be accurate and reliable.
This information is subject to change without notice. DMP - LOGO

        LT-0415 20161 © 2020 Digital Monitoring Products, Inc.