DANFOSS-logo

DANFOSS DM430E Series Display Engine Information Center EIC Software

DANFOSS-logo

Revision history Table of revisions

DateChangedRev
December 2018Minor change for print on demand, removed 2 blank pages at end of the manual for required total pages divisive by 4.0103
December 2018Added note in regards to keeping ambient light sensor area clean and uncovered for best operation.0102
December 2018First edition0101

User liability and safety statements

OEM responsibility

  • The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all consequences that might occur. Danfoss has no responsibility for any consequences, direct or indirect, caused by failures or malfunctions.
  • Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment.
  • Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the system being programmed in a manner that jeopardizes safety.
  • All safety critical systems shall include an emergency stop to switch off the main supply voltage for the outputs of the electronic control system. All safety critical components shall be installed in such a way that the main supply voltage can be switched off at any time. The emergency stop must be easily accessible to the operator.

Safety statements

Display operation guidelines

  • Disconnect your machine’s battery power before connecting power and signal cables to the display.
  • Before doing any electrical welding on your machine, disconnect all power and signal cables connected to the display.
  • Do not exceed the display power supply voltage ratings. Using higher voltages may damage the display and can create a fire or electrical shock hazard.
  • Do not use or store the display where flammable gases or chemicals are present. Using or storing the display where flammable gases or chemicals are present may cause an explosion.
  • Software configures the keypad buttons on the display. Do not use these buttons to implement critical safety features. Use separate mechanical switches to implement critical safety features such as emergency stops.
  • Design systems that use the display so that a communication error or failure between the display and other units cannot cause a malfunction that might injure people or damage material.
  • The protective glass over the display screen will break if hit with a hard or heavy object. Install the display to reduce the possibility of it being hit by hard or heavy objects.
  • Storing or operating a display in an environment that exceeds the display specified temperature or humidity rating may damage the display.
  • Always clean the display with a soft, damp cloth. Use a mild dishwashing detergent as needed. To avoid scratching and discoloring the display, do not use abrasive pads, scouring powders, or solvents such as alcohol, benzene, or paint thinner.
  • Keep ambient light sensor area clean and uncovered for best operation.
  • Danfoss graphical displays are not user serviceable. Return the display to the factory in case of failure.
Machine wiring guidelines

Warning

  • Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. Improperly protected power input lines against over current conditions may cause damage to the hardware. Properly protect all power input lines against over-current conditions. To protect against unintended movement, secure the machine.

Caution

  • Unused pins on mating connectors may cause intermittent product performance or premature failure. Plug all pins on mating connectors.
  • Protect wires from mechanical abuse, run wires in flexible metal or plastic conduits.
  • Use 85˚ C (185˚ F) wire with abrasion resistant insulation and 105˚ C (221˚ F) wire should be considered near hot surfaces.
  • Use a wire size that is appropriate for the module connector.
  • Separate high current wires such as solenoids, lights, alternators or fuel pumps from sensor and other noise-sensitive input wires.
  • Run wires along the inside of, or close to, metal machine surfaces where possible, this simulates a shield which will minimize the effects of EMI/RFI radiation.
  • Do not run wires near sharp metal corners, consider running wires through a grommet when rounding a corner.
  • Do not run wires near hot machine members.
  • Provide strain relief for all wires.
  • Avoid running wires near moving or vibrating components.
  • Avoid long, unsupported wire spans.
  • Ground electronic modules to a dedicated conductor of sufficient size that is connected to the battery (-).
  • Power the sensors and valve drive circuits by their dedicated wired power sources and ground returns.
  • Twist sensor lines about one turn every 10 cm (4 in).
  • Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors.

Machine welding guidelines Warning

  • High voltage from power and signal cables may cause fire or electrical shock, and cause an explosion if flammable gasses or chemicals are present.
  • Disconnect all power and signal cables connected to the electronic component before performing any electrical welding on a machine.
  • The following is recommended when welding on a machine equipped with electronic components:
  • Turn the engine off.
  • Remove electronic components from the machine before any arc welding.
  • Disconnect the negative battery cable from the battery.
  • Do not use electrical components to ground the welder.
  • Clamp the ground cable for the welder to the component that will be welded as close as possible to the weld.

Overview

DM430E Series Display package

  • Prior to use, ensure the following are included in the display package:
  • DM430E Series Display
  • Panel Seal Gasket
  • DM430E Series Display – Engine Information Center (EIC) User Manual

DM430E literature references Reference literature

Literature titleLiterature typeLiterature number
DM430E Series PLUS+1® Mobile Machine DisplaysTechnical InformationBC00000397
DM430E Series PLUS+1® Mobile Machine DisplaysData SheetAI00000332
DM430E Series Display – Engine Information Center (EIC) SoftwareUser ManualAQ00000253
PLUS+1® GUIDE SoftwareUser ManualAQ00000026

Technical Information (TI)

  • A TI is comprehensive information for engineering and service personnel to reference.

Data Sheet (DS)

  • A DS is summarized information and parameters that are unique to a specific model.

API Specifications (API)

  • An API is specifications for programming variable settings.
  • API specifications are the definitive source of information regarding pin characteristics.

PLUS+1® GUIDE User Manual

  • The Operation Manual (OM) details information regarding the PLUS+1® GUIDE tool used in building PLUS+1® applications.

This OM covers the following broad topics:

  • How to use the PLUS+1® GUIDE graphical application development tool to create machine applications
  • How to configure module input and output parameters
  • How to download PLUS+1® GUIDE applications to target PLUS+1® hardware modules
  • How to upload and download tuning parameters
  • How to use the PLUS+1® Service Tool

Latest version of technical literature

  • Comprehensive technical literature is online at www.danfoss.com
  • The DM430E comes installed with the powerful and flexible Danfoss Engine Information Center (EIC) J1939 engine monitor software application. Use the application to customize the look and feel of your individual engine monitoring needs by creating and controlling analog and digital display information in the screen configurations that work best for your performance requirements.
  • Navigate through diagnostic information and configuration screens with ease by using the four context-dependent soft keys located at the front of the display. Choose from more than 4500 different monitoring parameter profiles to customize the DM430E.
  • Up to four signals can be monitored on each screen. Use the EIC software to configure the DM430E for alarms and alerts.

Navigation using soft keys

The DM430E is controlled by navigation through a set of four soft keys located at the lower front of the display. The keys are context dependent. Soft key selection options are displayed above each key and are dependent on the current navigation location within the engine monitor software program. As a general rule, the far right soft key is the selector button and the far left soft key is the step back one screen key. To optimize full screen use, the on-screen selections are not displayed when not in use. Press any soft key to display current selection options.
Navigation using soft keysDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-1

Screen navigation

Navigate UpPress to move up through menu items or screens
Navigate DownPress to move down through menu items or screens
Main MenuPress to go to Main Menu screen
Exit/Back one screenPress to go back one screen
SelectPress to accept selection
Next MenuPress to select next digit or screen element
Inhibit RegenPress to force regeneration of particulate filter
Initiate RegenPress to inhibit particulate filter regeneration
Increment/decrementPress to increment or decrement value

Initiate and inhibit regeneration

  • While EIC DM430E is displaying one of the monitor screens, pressing any soft key will show the available navigation actions in an action menu.
  • There are two separate action menus on this level, the first one to appear contains the following actions (from left to right).
  • Next Menu
  • Navigate Up
  • Navigate Down
  • Main Menu
  • Selecting Next Menu will display the second action menu with Inhibit switch (Inhibit Regeneration), Initiate switch (Initiate Regeneration) and RPM Set Point. Pressing it again will show the first set of actions once more. Selecting Navigate Up and Navigate
  • Down will allow navigation between signal monitoring screens. Selecting Main Menu will display the DM430E set up options. If no soft keys are pressed and released for 3 seconds while the action menu is shown, the menu will disappear and the actions are no longer available. Pressing (and releasing) any soft key will activate the first menu once more.

Inhibit Regeneration action

  • If the user selects the Inhibit Regeneration action while the action menu is being displayed the same function as described in Initiate Regeneration action will be executed, with the following.
  • Bit 0 (out of 0-7) in byte 5 (out of 0-7) is set to 1 (true).
  • The pop up reads Inhibit Regen.
  • The acknowledgment lights up the Regeneration Inhibit LED.

Initiate Regeneration action

  • If the user selects the Initiate Regeneration action while the action menu is being displayed; bit 2 (out of 0-7) in byte 5 (out of 0-7) will be set to 1 (true) in the J1939 message PGN 57344 bound for the engine. This change prompts the message to be transmitted. The bit will stay like this for the duration of the soft key press or for the 3 second countdown to soft key inactivity, whichever occurs first. The bit is then reset to 0 (false).
  • The soft key press also prompts the display to show a pop up lasting for 3 seconds. This popup simply says Initiate Regen. If the display does not receive an acknowledgment from the engine on the change to message PGN 57344 the last half of the pop up will read No Engine Signal. This acknowledgment is the command that lights up the Initiate Regeneration LED on the display unit housing.

TSC1 RPM setpoint

  • The TSC1 message sends the RPM requirement for the engine.
Main Menu

Use the Main Menu as the starting point for configuring the DM430E Series Display. Main Menu screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-2

Main Menu

Basic SetupUse to set Brightness, Color Theme, Time & Date, Language, Units
DiagnosticsUse to view system, fault log and device information
Screen SetupUse to select screens, number of screens and parameters (can be PIN protected)
System SetupUse to reset defaults and trip information, access CAN information, select display settings, and configure PIN settings

Basic Setup menu

Use Basic Setup to set brightness, color theme, time & date, language, and units for the DM430E Series Display.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-3

Basic Setup menu

BrightnessUse to adjust brightness level of the screen
Color ThemeUse to set background color of display
Time & DateUse to set time, date, and time and date styles
LanguageUse to set the system language, default language is English
UnitsUse to set speed, distance, pressure, volume, mass, temperature and flow settings

Brightness
Use the minus (-) and plus (+) soft keys to adjust display screen brightness. After 3 seconds of inactivity the screen will go back to basic setup.
Brightness screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-4

Color Theme
Use to select between 3 options of Light, Dark and Automatic. Color Theme screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-5

Time & Date
Use up, down, select, and next soft keys to set time style, time, date style, and date. Time & Date screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-6

Language
Use up, down and select soft keys to select program language. Available languages are English, Spanish, French, German, Italian, Swedish and Portuguese.
Language screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-7

Units
Use up, down, and select soft keys to define units of measurement.

Units of measurement

Speedkph, mph
Distancekm, miles
PressurekPa, bar, psi
Volumelitre, gal, igal
Masskg, lbs
Temperature°C, °F
Flowlph, gph, igph

Diagnostics menu

Use to obtain system info, fault log entries, and device information. Diagnostics screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-8

Diagnostics menu

System InfoUse to display hardware, software, system, and node information for connected devices
Fault LogUse to view and monitor current and previous fault information
Device ListUse to display list of all currently connected J1939 devices

System Info
The System Info screen contains hardware serial number, software version, node number and ROP version.
System Info screen exampleDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-9

Fault Log
The Fault Log screen contains saved and stored fault information. Select either Active Faults or Previous Faults to monitor fault activity. Select specific faults to list more information.
Fault Log screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-10

Active faults

  • Select Active Faults to display all active faults on the CAN network.

Previous faults

  • Select Previous Faults to display all previously active faults on the CAN network.

Device List

  • The Device List screen lists J1939 devices and addresses that are currently being monitored on the network.

Screen Setup menu

Use Screen Setup to select individual screens for setup, and number of signal screens.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-11

Screen Setup menu

Select ScreensSelect screen to set up signal information, screens available are dependent on Number of Screens selection
Number of ScreensSelect 1 to 4 screens for information display

Select Screens

  • Select screen to customize. For screen set up details, see Setup to monitor signals.
  • Select Screens exampleDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-12

Number of Screens

  • Select number of screens for display. Choose from 1 to 4 screens. For screen set up details, see Setup to monitor signals.

Number of Screens exampleDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-13

  • Use System Setup to monitor and control application systems.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-14

System Setup menu

Reset DefaultsUse to reset all system information to the default settings
CANUse to customize CAN settings
DisplayUse to customize display settings
PIN SetupUse to customize PIN settings
Trip ResetUse to reset trip information

Reset Defaults
Select Reset Defaults to reset all EIC settings to original factory default settings.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-15

CAN
Use the CAN settings screen to make the following selections.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-16

CAN settings menu

Fault PopupSelect on/off to enable/disable pop-up messages.
Conversion MethodSelect 1, 2 or 3 to determine how to interpret non- standard fault messages. Consult engine manufacturer for correct setting.
Engine AddressSelect engine address. Selection range is 0 to 253.
Engine TypeSelect from a list of predetermined engine types.
Engine DMs OnlyOnly accepts fault codes or J1939 DM messages from the engine.
Transmit TSC1Enable to send the TSC1 (Torque Speed Control 1) message.
JD InterlockTransmit John Deere Interlock message required for regeneration.

DisplayDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-17

Display Setting

Startup ScreenSelect to enable/disable logo display at startup.
Buzzer OutputSelect to enable/disable warning buzzer functionality.
Force Return to GaugesAfter 5 minutes of inactivity returns to main Gauge.
Demo ModeSelect on/off to enable demonstration mode.

PIN Setup

  • To reduce the potential for errors, Screen Setup and System Setup menu options can only be accessed after entering a PIN code.
  • The default code is 1-2-3-4. To change PIN code go to System Setup > PIN Setup > Change PIN Code.

PIN SetupDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-18

Trip Reset
Select Yes to reset all trip data.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-19

Setup to monitor signals

  • The following steps are for screen setup. Steps 1 through 3 are for selecting number of screens and screen types and 4 through 7 are for selecting J1939 monitor controls.
  • For J1939 parameters available, function and symbols, reference Symbols for J1939 parameters.
  1.  Navigate to Main Menu > Screen Setup > Number of Screens. Select from one to four screens for signal monitoring.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-20
  2. Navigate to Main Menu > Screen Setup > Select Screens and select screen to customize.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-21
  3. Select screen type for each of the screens selected. There are four screen variants.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-22

Screen type 1
Type 1 is a two-up screen view with two signal capacity.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-23

Screen type 2

  • Type 2 is a three-up view with one large signal display capacity and behind it, partially visible, are two small signal display capacities.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-24

Screen type 3

  • Type 3 is a three-up view with one large and two small signal display capacities.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-25

Screen type 4

  • Type 4 is a four-up view with four small signal display capacities.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-26
  • For more screen type customization it is possible to configure the small signal displays by choosing from three styles.
  • After choosing the gauge to modify, press select key, a screen called Modify What? will open.
  • Within this screen it is possible to modify the signal and advanced parameters. Additionally, for screen type 3 and 4, the gauge type can also be modified.

Modify What? screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-27

Modify What?

SignalUse to define the signal you would like to display.
Advanced ParametersUse to define gauge icon, range, multiplier and tick settings.
Gauge TypeUse to define gauge appearance.

When modifying signal, 3 signal types are available.

Signal Type screenDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-28

Signal Type

Standard J1939Choose from over 4500 signal types.
Custom CANChoose a CAN signal.
HardwareChoose hardware specific signals.
  • When choosing Standard J1939, it is possible to search for available signals. Choose between Text PGN and SPN search types.
  • Use the left and right arrow soft keys to cycle through the alphabet and enter the signal.
  • Search for the signal screen.DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-29
  • After making a signal selection, press the right arrow soft key to go to the next selection area.
  • Use left arrow, right arrow, and next soft keys to select signal monitoring screen.
  • Use the right arrow soft key to rotate through the selections in a clockwise rotation.

Examples of screen signal selectionsDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-30

  • Complete screen signal selections then press the back symbol soft key to return to previous menus.
  • Navigate back for more screen selections or press the back soft key until you reach the Main Screen.

Example of screen setupDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-31

Symbols for J1939 parameters

The following table lists symbols for the J1939 engine and transmission parameters that are available and can be monitored.

Symbols for the J1939 engine and transmission parametersDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-32 DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-33 DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-34 DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-35

LED indicators

Particulate filter lamp

  • Stage 1 The right Amber LED indicates the initial need for regeneration.
    • The lamp is on solid.
  • Stage 2 The right Amber LED indicates an urgent regeneration.
    • Lamp flashes with 1 Hz.
  • Stage 3 Same as Stage 2 but check engine lamp will also turn on.
    • High exhaust system temperature lamp
  • The left Amber LED indicates the increase of exhaust system temperature due to regeneration.
    • Regeneration disabled lamp
  • The left Amber LED indicates that the regeneration disabled switch is active.

Installation and mounting

Mounting
Recommended mounting procedure mm [in]DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-36

CalloutDescription
APanel opening for mounting on surface A
BPanel opening for mounting on surface B
1Panel seal
2Panel bracket
3Four screws

Installation and mounting

Fastening

Caution

  • Use of non-recommended screws can cause damage to housing.
  • Excessive screw torque force can cause damage to housing. Maximum torque: 0.9 N m (8 in-lbs).
  • Reassembly with self-tapping screws can damage existing threads in housing.
  • Oversized panel cutouts can jeopardize product IP rating.
  • Ensure the vent is not covered. This excludes the RAM mount option.

Fastening hole depth mm [in]DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-37

  • Fastening hole depth: 7.5 mm (0.3 in). Standard M4x0.7 screw may be used.
  • Maximum torque: 0.9 N m (8 in-lbs).

Pin assignments

  • 12 pin DEUTSCH connectorDANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-38

DEUTSCH DTM06-12SA 12 pin

C1 pinDM430E-0-x-x-xDM430E-1-x-x-xDM430E-2-x-x-x
1Power ground –Power ground –Power ground –
2Power supply +Power supply +Power supply +
3CAN 0 +CAN 0 +CAN 0 +
4CAN 0 –CAN 0 –CAN 0 –
5AnIn/CAN 0 ShieldAnIn/CAN 0 ShieldAnIn/CAN 0 Shield
6DigIn/AnInDigIn/AnInDigIn/AnIn
C1 pinDM430E-0-x-x-xDM430E-1-x-x-xDM430E-2-x-x-x
7DigIn/AnInDigIn/AnInDigIn/AnIn
8DigIn/AnInCAN 1+Sensor power
9DigIn/AnInCAN 1-Secondary power input*
10Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)
11Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)Multifunction input (DigIn/AnIn/Freq/4-20 mA/Rheostat)
12Digital out (0.5A sinking)Digital out (0.5A sinking)Digital out (0.5A sinking)

From controller (requires surge protection).DANFOSS-DM430E-Series-Display-Engine-Information-Center-EIC-Software-fig-39

M12-A 8 pin

C2 pinFunction
1Device Vbus
2Device data –
3Device data +
4Ground
5Ground
6RS232 Rx
7RS232 Tx
8NC

Ordering information

Model variants

Part numberOrder codeDescription
11197958DM430E-0-0-0-04 Buttons, I/O
11197973DM430E-1-0-0-04 Buttons, 2-CAN
11197977DM430E-2-0-0-04 Buttons, Sensor Power, Secondary Power Input
11197960DM430E-0-1-0-04 Buttons, I/O, USB/RS232
11197974DM430E-1-1-0-04 Buttons, 2-CAN, USB/RS232
11197978DM430E-2-1-0-04 Buttons, Sensor Power, Secondary Power Input, USB/RS232
11197961DM430E-0-0-1-0Navigation Buttons, I/O
11197975DM430E-1-0-1-0Navigation Buttons, 2-CAN
11197979DM430E-2-0-1-0Navigation Buttons, Sensor Power, Secondary Power Input
11197972DM430E-0-1-1-0Navigation Buttons, I/O, USB/RS232
11197976DM430E-1-1-1-0Navigation Buttons, 2-CAN, USB/RS232
11197980DM430E-2-1-1-0Navigation Buttons, Sensor Power, Secondary Power Input, USB/RS232
11197981DM430E-0-0-0-14 Buttons, I/O, EIC Application
11197985DM430E-1-0-0-14 Buttons, 2-CAN, EIC Application
11197989DM430E-2-0-0-14 Buttons, Sensor Power, Secondary Power Input, EIC Application
11197982DM430E-0-1-0-14 Buttons, I/O, USB/RS232, EIC Application
11197986DM430E-1-1-0-14 Buttons, 2-CAN, USB/RS232, EIC Application
11197990DM430E-2-1-0-14 Buttons, Sensor Power, Secondary Power Input, USB/RS232, EIC Application
11197983DM430E-0-0-1-1Navigation Buttons, I/O, EIC Application
11197987DM430E-1-0-1-1Navigation Buttons, 2-CAN, EIC Application
11197991DM430E-2-0-1-1Navigation Buttons, Sensor Power, Secondary Power Input, EIC Application
11197984DM430E-0-1-1-1Navigation Buttons, I/O, USB/RS232, EIC Application
11197988DM430E-1-1-1-1Navigation Buttons, 2-CAN, USB/RS232, EIC Application
11197992DM430E-2-1-1-1Navigation Buttons, Sensor Power, Secondary Power Input, USB/RS232, EIC Application

Model code

ABCDE
DM430E    

Model code key

A—Model nameDescription
DM430E4.3″ Color Graphical Display
B—Inputs/OutputsDescription
01 CAN Port, 4DIN/AIN, 2 MFIN
12 CAN Port, 2DIN/AIN, 2 MFIN
21 CAN Port, 2DIN/AIN, 2 MFIN, Sensor Power
C—M12 connectorDescription
0No USB Device, No RS232
1USB Device, RS232

Ordering information

D—Button PadsDescription
04 Buttons, 6 LEDs
1Navigation buttons, 2 Dual-color LEDs
E—Application key (EIC Application)Description
0No Application Key
1Application Key (EIC Application)
Related products

Connector bag assembly

10100944DEUTSCH 12-pin Connector Kit (DTM06-12SA)

Connector and cable kit

11130518Cable, M12 8-Pin to USB Device
11130713Cable, M12 8-Pin to Lead Wires

Connection tools

10100744DEUTSCH stamped contacts terminal crimp tool, size 20
10100745DEUTSCH solid contacts terminal crimp tool

Mounting kit

11198661Panel mounting kit

Software

11179523

(annual renewal with 11179524 to keep the software updates)

PLUS+1® GUIDE Professional Software (includes 1 year of software updates, a single user license, Service and Diagnostic Tool and Screen Editor)
OnlineJ1939 CAN EIC Engine Monitor Software*

Products we offer:

  • DCV directional control valves
  • Electric converters
  • Electric machines
  • Electric motors
  • Hydrostatic motors
  • Hydrostatic pumps
  • Orbital motors
  • PLUS+1® controllers
  • PLUS+1® displays
  • PLUS+1® joysticks and pedals
  • PLUS+1® operator interfaces
  • PLUS+1® sensors
  • PLUS+1® software
  • PLUS+1® software services,support and training
  • Position controls and sensors
  • PVG proportional valves
  • Steering components and systems
  • Telematics
  • Comatrol www.comatrol.com
  • Turolla www.turollaocg.com
  • Hydro-Gear www.hydro-gear.com
  • Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com
  • Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electric components.
  • We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the marine sector.
  • Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications.
  • We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster.
  • Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile electrification.
  • Go to www.danfoss.com for further product information.
  • We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance.
  • And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components.

Local address:

  • Danfoss
  • Power Solutions (US) Company
  • 2800 East 13th Street
  • Ames, IA 50010, USA
  • Phone: +1 515 239 6000
  • Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.
  • Danfoss reserves the right to alter its products without notice.
  • This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
  • All trademarks in this material are property of the respective companies.
  • Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • www.danfoss.com

Documents / Resources

DANFOSS DM430E Series Display Engine Information Center EIC Software [pdf] User Manual
DM430E Series Display Engine Information Center EIC Software, DM430E Series, Display Engine Information Center EIC Software, Center EIC Software, EIC Software, Software

References

Leave a comment

Your email address will not be published. Required fields are marked *