BOSCH-LOGO

BOSCH Updates System Manager Software

BOSCH -Updates -System -Manager-Software

Document History

This document is distributed online and updated on regular basis, whenever new patches are released and added to the package. The latest version of this document is always available on the Bosch Security and Safety Systems Download Store.

DateVersionChanges
20.06.20241.0Initial release – for BVMS Cumulative Patch 2
21.10.20241.1Updated for BVMS Cumulative Patch 3 + VRM 4.41.0020 + VSG 9.2.1.2 + Transcoder 7.10.62
19.11.20241.2Updated for VRM 4.42.0028
07.02.20251.3Updated for BVMS Cumulative Patch 5
20.03.20251.4Updated for BVMS Cumulative Patch 6
12.05.20251.6Updated for VSG 9.2.1.4

BVMS 12.2.0 Updates System Manager package

DIVAR IP System Manager application is the central user interface that offers an easy system setup, configuration and application software upgrade for DIVAR IP all-in-one 4000, DIVAR IP all-in-one 5000, DIVAR IP all-in-one 6000 and DIVAR IP all-in-one 7000 (DIP-72xx, DIP-73xx, DIP-74xx) systems.
The BVMS_12.2.0_Updates_SystemManager_package_1.6.1.zip contains a BVMS 12.2.0 Cumulative Patch 6 patch installer software package for the DIVAR IP System Manager application. It also contains updated VRM, VSG, and Transcoder Service installer software packages for the DIVAR IP System Manager application. It is used to install the patch and other updated components for BVMS 12.2.0 on the DIVAR IP appliances managed by the DIVAR IP System Manager.

Installation prerequisites and operation notes

DIVAR IP System Manager application version 2.4 or higher shall be installed and started.  To download the BVMS 12.2.0 Updates System Manager package 1.6.1,  go to https://downloadstore.boschsecurity.com/ Then, under the Software tab, select BVMS Appliances from the list and click Select.
Locate the BVMS_12.2.0_Updates_SystemManager_package_1.6.1.zip file from the list of all available software packages, and save it to a storage medium such as a USB stick. Unzip the files on the storage medium. Do not change the folder structure of the unzipped files.
Connect the storage medium to your DIVAR IP system and follow instructions in the Upgrading software section of, for example,  DIVAR IP all-in-one 4000 / 6000 systems User Manuals to install desired BVMS patches or components updates on your DIVAR IP.

List of components, compatible with BVMS 12.2.0, available in the package
VRM 4.42.0028, refer to corresponding release notes
VSG 9.2.1.4, refer to corresponding release notes
Transcoder Service 7.10.62

Known limitations and issues
N/A

BVMS 12.2 – Cumulative Patch history

No.Patch versionRelease Date
1Cumulative Patch 104.06.2024
2Cumulative Patch 208.06.2024
3Cumulative Patch 315.10.2024
4Cumulative Patch 420.11.2024
5Cumulative Patch 520.01.2025
6Cumulative Patch 620.02.2025

Patches included in the Cumulative Patch 6 for BVMS 12.2

Overview

No.Name of the fixIncluded in
1434867 – Instant replay display issuesCumulative Patch 6,5,4,3,2,1
2454258 – State update of Virtual InputsCumulative Patch 6,5,43,2
3461469 – I-frame problems for CPP13 and CPP14 camerasCumulative Patch 6,5,4,3
4465447 – Operator Client crash with Axis metadata streamsCumulative Patch 6,5,4,3
5463213 – Timeline view performance problemsCumulative Patch 6,5,4,3
6464025 – SSH not working for CameoSDKCumulative Patch 6,5,4,3
7456230 – LDAP SSO login issuesCumulative Patch 6,5,4,3
8461659 – Login issues using CameoSDKCumulative Patch 6,5,4,3
9455696 – Black screen for Axis camerasCumulative Patch 6,5,4,3
10466016 – High CPU load with ADAM devicesCumulative Patch 6,5,4
11462731 – Increased CPU loadCumulative Patch 6,5,4
12463959 – SSH link for CSV file importCumulative Patch 6,5,4
13464745 – Operator Client crashingCumulative Patch 6,5
14464761 – FQDN missing in the certificateCumulative Patch 6,5
15468180 – Config Client crashing with VCA configurationCumulative Patch 6,5
16471029 – Licensing problemCumulative Patch 6,5
17468194 – Errors when retrieving video stream during playbackCumulative Patch 6,5
18465633 – Camera name cut to 31 charactersCumulative Patch 6,5
19463115 – OIDC login via proxy serversCumulative Patch 6,5
20465834 – Protect/Unprotect improvements for with bigger number of camerasCumulative Patch 6,5
No.Name of the fixIncluded in
21470057 – OIDC support for web browserCumulative Patch 6

Detailed Release Notes for the patch

Patch ID:470057, 464745, 464761, 468180, 471029, 468194, 465633, 463115, 465834,

466016, 462731, 463959, 461469, 465447, 463213, 464025, 456230, 461659,

455696, 434867, 454258

Patch Title:BVMS 12.2 – Cumulative Patch 6
Patch Target Version:BVMS-12.2.0.296

Patch Details:

  • This patch fixes issue 470057 by supporting the standard web browser of the system.
  • This patch fixes issue 464745 by preventing the Operator Client to crash.
  • This patch fixes issue 464761 by displaying the Fully Qualified Domain Name (FQDN) in the BvmsAuth certificate.
  • This patch fixes issue 468180 by preventing the Config Client to crash when the metadata tab under VCA is
  • selected with CPP13 and CPP14 cameras.
  • This patch fixes issue 471029 by license improvements.
  • This patch fixes issue 468194 by showing playback errors in cameo if the following Registry Key exists.
  • [HKEY_LOCAL_MACHINE\SOFTWARE\Bosch\BVMS\ImageDecoder]
  • ShowPlaybackErrorsInCameo”=dword:00000001
  • This patch fixes issue 465633 by using camera names up to 63 characters (Logbook part available with BVMS 12.3).
  • This patch fixes issue 463115 by improving the OIDC login via proxy server.

Manual action:
When using a proxy for OIDC connection you need to add your proxy address in the file “appsettings.json” in the folder \bin\AuthorizationService of the section “Proxysettings”. Save the file and restart the “BVMS Authorization Service” via the Services manager in Windows.
This patch fixes issue 465834 by improving the protect / unprotect functionality in Operator Client.
It is recommended to use the VRM 4.42.28, as a corresponding bugfix was also done in VRM (can be downloaded separately).

  • This patch fixes issue 466016 by improvements with regards to the ThreadPool of AdamDevices.
  • This patch fixes issue 462731 by improving the BVMS Management Server (Central Server).
  • This patch fixes issue 463959 by improving the import of unmanaged sites via CSV.
  • This patch fixes issue 461469 by improving the i-Frame request handling.
  • This patch fixes issue 465447 by preventing the Operator Client to crash.
  • This patch fixes issue 463213 by improving the performance of the timeline view in Operator Client.
  • This patch fixes issue 464025 by allowing SSH connections in CameoSDK.
  • This patch fixes issue 456230 by improving the login via LDAP SSO.
  • This patch fixes issue 461659 by improving the CameoSDK integration.
  • This patch fixes issue 455696 by improving the H264 video packet handling. The Video Streaming Gateway (VSG) 9.2.1.2 is needed.
  • This patch fixes issue 434867 by improving video streaming when starting instant playback.
  • This patch fixes issue 454258 by improving the state update of virtual inputs.

Problem Details:

  • Issue 470057 caused the problem that with OIDC authentication the WebView2 control does not support plugins.
  • Issue 464745 caused the Operator Client to crash.
  • Issue 464761 caused the problem that the Fully Qualified Domain Name (FQDN) was missing in the BvmsAuth certificate.
  • Issue 468180 caused the Config Client to crash when the metadata tab under VCA is selected with CPP13 and CPP14 cameras.
  • Issue 471029 caused a licensing problem.
  • Issue 468194 caused that the error message “error while retrieving video stream (code 3)” is shown for a camera in playback mode when moving the camera to a cameo.
  • A video is shown instead of the error message if the user jumps to an earlier point in the timeline.
  • Issue 465633 caused the problem that camera names always cut to 31 characters in the camera config.
  • Issue 463115 caused the problem that OIDC login via proxy server is not possible.
  • Issue 465834 caused the problem that the protect / unprotect functionality in Operator Client was not working reliable if a lot of cameras are involved.
  • Issue 466016 caused the problem that the Management Server (Central Server) has sometimes high CPU usage in the area of using AdamDevices.
  • Issue 462731 caused the problem that the Management Server (Central Server) has sometimes high CPU usage.
  • Issue 463959 caused the problem that SSH connection URL for DIPs/BVMS are not supported, when importing unmanaged sites via CSV.
  • Issue 461469 caused too many i-Frame requests for CPP13 & CPP14 cameras if during livestream UDP packages get lost.
  • Issue 465447 caused the problem that the Operator Client crashes if specific Metadata in Axis camera is enabled.
  • Issue 463213 caused the problem of a slow performance of the timeline view in Operator Client.
  • Issue 464025 caused the problem that with CameoSDK no ssh connection possible.
  • Issue 456230 caused the problem that logging in with LDAP SSO is not possible.
  • Issue 461659 caused the problem that logging into individual sites using the CameoSDK integration, “WrongSchedule” issue appears.
  • Issue 455696 caused the problem that black screen is shown in live view using Axis camera via VSG with H264.
  • Issue 434867 caused the problem that black video is shown while going to instant playback on alarm.
  • Issue 454258 caused the problem that the state of virtual inputs does not update correctly unless you are in the logical tree or when you move to the logical tree.

Affected Bosch VMS Components / Machines:

  • Bosch VMS Management Server
  • Bosch VMS Operator Client
  • Bosch VMS Configuration Client
  • Bosch VMS Cameo SDK
  • Video Streaming Gateway (VSG) 9.2.1.2, needs to be downloaded seperately

List of Replaced Files:

  • AppData\Client\OpClient\ApplicationWiring\OpClient\Spring.Bootstrap.xml
  • AppData\Server\CentralServer\DeviceConfigurator.xml
  • Conf\DeviceConfig\groups\Camera_ALC_AutoDome_xx_7000.xml
  • AuthorizationService\appsettings.json
  • AuthorizationService\BvmsAuthorizationService.dll [Version 12.2.0.319]
  • AuthorizationService\BvmsAuthorizationService.exe [Version 12.2.0.319]
  • Bosch.Utilities.dll [Version 12.2.0.325]
  • Bosch.Vms.CameoSdk.Core.dll [Version 12.2.0.309]
  • Bosch.Vms.Client.OpClient.Application.ClientSupport.dll [Version 12.2.0.325]
  • Bosch.Vms.Client.OpClient.Common.Wpf.dll [Version 12.2.0.325]
  • Bosch.Vms.Client.OpClient.Dibos.ArchiveAction.dll [Version 12.2.0.317]
  • Bosch.Vms.Client.OpClient.VideoComp.ImageDecoder.Control.dll [Version 12.2.0.320]
  • Bosch.Vms.Client.OpClient.VideoComp.Impl.dll [Version 12.2.0.324]
  • Bosch.Vms.Config.DeviceTree.Extension.UnmonitoredSiteExtensions.dll [Version 12.2.0.312]
  • Bosch.Vms.Config.VcsConfigHelper.dll [Version 12.2.0.318]
  • Bosch.Vms.Core.IUserAuthenticationService.dll [Version 12.2.0.303]
  • Bosch.Vms.Core.UserAuthenticationCommon.dll [Version 12.2.0.303]
  • Bosch.Vms.Core.UserAuthenticationLdap.dll [Version 12.2.0.303]
  • Bosch.Vms.Frontend.OpClient.ObjectStateTable.Imp.dll [Version 12.2.0.298]
  • Bosch.Vms.Frontend.OpClient.OpClientLogOn.dll [Version 12.2.0.325]
  • Bosch.Vms.Frontend.OpClient.ServerManagement.dll [Version 12.2.0.325]
  • Bosch.Vms.Frontend.OpClient.StateService.dll [Version 12.2.0.298]
  • Bosch.Vms.Frontend.OpClient.UiStrings.dll [Version 12.2.0.325]
  • Bosch.Vms.Frontend.OpClient.Wcf.dll [Version 12.2.0.298]
  • Bosch.Vms.Frontend.Shared.ConfigurationApi.If.dll [Version 12.2.0.318]
  • Bosch.Vms.Frontend.Shared.RcppCapabilities.dll [Version 12.2.0.318]
  • Bosch.Vms.Frontend.Shared.RcppCapabilities.Imp.dll [Version 12.2.0.318]
  • Bosch.Vms.Server.AdamAdapter.dll [Version 12.2.0.316]
  • Bosch.Vms.Server.AuthConfigurationService.Impl.dll [Version 12.2.0.323]
  • Bosch.Vms.Server.FeatureSupport.dll [Version 12.2.0.321]
  • Bosch.Vms.Service.Server.Modules.Vcs.VcsDeviceConfigurator.Impl.dll [Version 12.2.0.318]
  • Bosch.Vms.Service.Server.Modules.Vcs.VcsService.dll [Version 12.2.0.315]
  • Bosch.Vms.Shared.Licensing.dll [Version 12.2.0.321]
  • Bosch.Vms.Shared.ScheduleManager.dll [Version 12.2.0.302]
  • Bosch.Vms.Shared.UserAuthentication.UserAuthenticationService.UserManagementLdap.dll [Version 12.2.0.303]
  • Bosch.Vms.Shared.Vcs.RcpCallSequencer.dll [Version 12.2.0.318]
  • Bosch.Vms.Shared.Vcs.RcpCallSequencer.Impl.dll [Version 12.2.0.318]
  • Bosch.Win32.dll [Version 12.2.0.325]
  • BVIP_VDP2.dll [Version 3.10.0.49]
  • BvmsCentralServer.exe.config
  • ConfigClient.exe.config
  • ConfigWizard.exe.config
  • DecoderLibrary.dll [Version 2.12.2.209]
  • ExportPlayer.exe [Version 12.2.0.325]
  • GCA2.dll [Version 6.40.20.29576]
  • OperatorClient.exe [Version 12.2.0.325]
  • OperatorClient.exe.config
  • rcppmedia.dll [Version 3.10.40.0]
  • VL_ConfigManager.dll [Version 7.72.128.0]

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

Frequently Asked Questions

  • Q: How often should I update BVMS 12.2.0 SystemManager package?
    A: It is recommended to check for updates at least once a month to ensure you have the latest features and security patches.
  • Q: Can I install the package on multiple devices?
    A: Yes, you can install the BVMS 12.2.0 SystemManager package on multiple devices as long as they meet the installation prerequisites.

Documents / Resources

BOSCH Updates System Manager Software [pdf] User Guide
DIP-72xx, DIP-73xx, DIP-74xx, Updates System Manager Software, Software

References

Leave a comment

Your email address will not be published. Required fields are marked *