AIREASE 27A05 Refrigerant Detection System

AIREASE 27A05 Refrigerant Detection System

REFRIGERANT DETECTION SYSTEM

What you need to know about field-installed kits

You need flexibility at the jobsite and our innovative multi-refrigerant coils and air handlers provide an easy solution for both R-410A system repairs and R-454B installations. Depending on the job and if the furnace is being replaced, you’ll need to ensure you have the right components on site.

Field-convertible Coils & Air Handlers

Convertible coils and air handlers ship to you ready for R-410A installations. Here’s what you need to know to convert them to R-454B refrigerant:

  1. You’ll need a R-454B TXV to replace the factory installed R-410A TXV in the convertible coil or air handler.
  2. A refrigerant sensor needs to be installed in the factory installed mounting bracket.
  3. Depending on the orientation of the air handler, the mounting bracket may need to be relocated. Units ship ready for up-flow installation.
  4. If the job has a furnace that does not have built-in refrigerant detection system controls, or you’re using a convertible air handler, you’ll need to add external controls to the system.
  5. Be sure to apply the supplied R-454B labels once the coil or air handler is converted.
  6. Refer to the chart for components needed in different applications.
Furnace or Air Handler Without Refrigerant Detection System Controls
Multi-refrigerant Coil27A05 – Non-communicating Controls
27A06 – Communicating Controls
26Z69 – Sensor
Dedicated
R-454B Coil
27A05 – Non-communicating Controls
27A06 – Communicating Controls
Multi-refrigerant
Air Handler
27A05 – Non-communicating Controls
27A06 – Communicating Controls
26Z69 – Sensor
Dedicated
R-454B Air
Handler
 

Factory-ready R-454B components

When you’re installing a dedicated R-454B coil and outdoor unit, coils have a factory installed sensor. For an existing furnace or if the new furnace does not have built-in refrigerant detection system controls, you’ll need external controls.

Air Handlers will ship from the factory with both the refrigerant detection system sensor and refrigerant detection system controls built-in – no field modification required.

Furnace or Air Handler With Built-in Refrigerant Detection System Controls
Multi-refrigerant Coil26Z69 – Sensor
Dedicated R-454B CoilNo Kit Needed
Multi-refrigerant Air Handler 
Dedicated R-454B Air HandlerNo Kit Needed