AJAX - Logo

12V PSU ee Buugga Isticmaalaha Hub/Hub Plus/ReX
La cusbooneysiiyay Diseembar 15, 2020

12V PSU ee Hub/Hub Plus/ReX waa unug sahay koronto ah, oo isku xiraya koontaroolada Hub/Hub Plus iyo sidoo kale fidinta raadiyaha ReX ilaa 12 volt DC ilo. Kani waa guddi elektaroonik ah, oo beddelaya halbeegga korantada ee 110/230 V ee jirka qalabka.

Ku xiridda

12V PSU ee Hub/Hub Plus/ReX waa inuu ku rakibaa koronto yaqaan tayo leh oo keliya.
Kahor intaadan rakibin qalabka korontada, hubi in qalabku ka go'an yahay khadka dhexe.
Markaad ku rakibayso 12V PSU ee Hub/Hub Plus/ReX, raac xeerarka badbaadada korantada ee guud, iyo sidoo kale shuruudaha xeerarka ilaalinta badbaadada korantada. Waligaa ha dumin aaladda inta uu ku hoos jiro voltage!

Habka rakibida:

  1. Remove the screws and take off the device from the SmartBracket mounting panel, shifting it down with force.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process
  2. Dami qalabka haysta badhanka korontada 2 ilbiriqsi.
  3. Ka saar korontada iyo fiilooyinka Ethernet.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process 2
    Sug 5 daqiiqo ilaa capacitors-ku soo daayo.
  4. Ka saar afar boolal oo daboolka dambe ah oo ka qaad.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process 3
  5. Ka saar furayaasha ku dhejisan looxyada jirka qalabka.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process 4
  6. Si taxadar leh uga saar labada loox, adigoo ku haya hal diyaarad oo aan kala goyn. Looxyada dhexdooda waxaa jira xiriiriye: ha jebin.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process 5
  7. Ka saar cutubka korontada (board yar) ee sabuuradda weyn.
  8. Connect 12V PSU for Hub/Hub Plus/ReX to the mainboard using the eight- pin connector between them. Do not warp or bend the antennas while replacing the board: this can cause the device to malfunction.
    AJAX 17938 12V PSU for HubHub PlusReX Power Supply Unit - Installation process 6
  9. Isku-dubbaridi looxyada iyo jirka aaladda intii aad adkeyn lahayd furayaasha.
    Hubi in baytariga iyo fiilooyinkiisu aanay ahayn clamped. Marka si sax ah loo rakibo, looxyadu waxay u taagan yihiin dhammaan hagayaasha mana stagger. Ku hay looxyada daboolka dambe, ka rog qalabka. Kaadhka SIM-ka, korantada, iyo saldhigyada Ethernet waa inay si sax ah u ekaadaan saldhigyada u dhigma, iyo badhanka korontadu waa inuusan ku xirmin. Beddel macluumaadka ku saabsan Volume gelintatage on the device body to avoid incorrect power connections in the future. Use the special bundled sticker with the instruction.
  10. Ku xidh korontada (iyo fiilada Ethernet) saldhigyada ku habboon.
  11. Daar isha korantada ee 12 V.
    Ha ku xidhin fiilada korantada voltage taas oo dhaaftay gelinta la aqbali karotage.
  12. Ka beddel qalabka adoo haya badhanka awoodda 2 ilbidhiqsi.
  13. Xir oo x guddiga korka ee SmartBracket

Daar aaladda, sug ilaa inta la soo shubayo, oo hubi heerka awoodda dibadda ee abka Ajax. Haddii koronto aysan jirin, oo aad isticmaalayso adabtarada terminal, hubi polarity ee fiilooyinka ku xiran. Haddii aysan koronto jirin xitaa ka dib marka dib loo xiro, fadlan la xiriir Adeegga Taageerada.

Dayactirka

Qalabku uma baahna dayactir farsamo.

Qalabka Tech

Ku gal voltage 8-20 V DC
Volt Outputtage 4.65 V DC ± 3%
Daar voltage 8 V DC ± 2.5%
Dami voltage 6.9-7.5 V (waxay kuxirantahay culeyska)
Xilliga hadda jira <1 A
Waqti xaddidan 1,5 A
Isku xirka mashiinnada dhexe Socket: 6.5 × 2 mm
Ku dheji: 5.5 × 2,1 mm
cabbir 138 64 13 mm
Miisaanka 30 g

Set oo dhammaystiran

  1. Ajax 12V PSU ee Hub/Hub Plus/ReX
  2. adabtarada Terminalka
  3. Hagaha bilawga soonka

damaanad

Dammaanadda wax-soo-saarka AJAX SYSTEMS wax soo saarka ee mas'uuliyadda xaddidan wuxuu shaqeynayaa 2 sano kadib iibka.
If the device does not function correctly, please contact the Support Service first. In half of the cases, technical issues can be solved remotely!

Waajibaadka dammaanadda
Heshiiska User
Taageero farsamo: [emailka waa la ilaaliyay]

Dukumentiyada / Kheyraadka

AJAX 17938 12V PSU ee Hub/Hub Plus/ReX Unugga Korantada [pdf] Buugga isticmaale
17938, 12V PSU ee Cutubka Korantada Hubka, 12V PSU ee Cutubka Quwada Korontada

Leave a comment