FibroPool FH235-I 35,000 BTU Full Inverter Heat Pump User Manual:
FibroPool FH285-i — Nonstop Swim
FibroPool FH235-i — Nonstop Swim
File Info : application/pdf, 22 Pages, 9.23MB
DocumentDocumentWWW.FIBROPOOL.COM WARNING! Risk of electric shock! - A faulty electrical installation or excessively high voltage can lead to electric shock. - Installation of heat pumps should only be performed by an authorized technician. - Always disconnect the power supply before opening the heat pump for maintenance or repairs. - Do not connect the heat pump if the incoming voltage does not match the required voltage on the unit's information plate. - Do not operate the heat pump if there is visible damage to the incoming wiring. - Repairs should only be performed by a qualified technician unless otherwise instructed. Liability and warranty claims are excluded in the event of improper repairs. - Keep children away from the heat pump. - Ensure that the heat pump's wiring is properly grounded or bonded before operating. ATTENTION! - The manufacturer is not responsible for damage caused by people, foreign objects, or inappropriate installation against these guidelines. - Always provide proper ventilation and install away from any fire risks. - Do not disconnect or attempt repairs on any lines containing refrigerant. Refrigerant repairs should not be performed in any confined space. - It is vital to follow proper winterization procedures when the risk of hard freeze approaches, or the titanium heat exchanger risks being cracked or damaged. Such damage is not covered under the warranty and repairs will be the owner's responsibility. Table of Contents I. Included parts and accessories II. Safety Information III. Installation of the unit IV. Technical Specifications V. Electrical Wiring VI. Operating Instructions VII. Initial Operation VIII. Operation and maintenance IX. Error codes & Solutions X. WiFi-Function XI. Winterization XII. Warranty Information I. Included Parts and Accessories Each unit includes the following accessories: No. Name Qty. Use 1 Instruction Manual 1 PC Safety and installation manual (this document) 2 Drain-hose 1 PC Used to direct condensation away from the unit 3 Drain-hose adapter 1 PC Connects the unit to the drain hose 4 Rubber shock absorber 4 PCS Limits friction with installation location 5 Heat pump unit 1 SET Heats and cools water pumped through 6 Unions 2 SET Connects the heat pump to 1.5" PVC The heat pump requires the following components: No. Name 1 Pool pump 2 Filter system 3 Plumbing Qty. use 1 Moves water through the system 1 Prevents debris from reaching the unit 1 Connect the equipment and make circulation NOTE The exact amount and setup of the plumbing, valves, filter equipment, sterilizing equipment, etc. vary from one pool to another. At minimum, a pool pump and filter are required. It is not recommended to install auxiliary electric heaters in the system. If absolutely necessary, auxiliary heaters must be installed and operated by qualified technicians. Fibropool cannot provide support for auxiliary heating systems. Heat Pump Overview II. Safety Information Required Operating Conditions: 1. Power supply: 208-230V 50/60Hz. 2. Air temperature: 35°F-105°F 3. Water temperature range: 45°F-104°F in Heating Mode 45°F-82°F in Cooling Mode NOTE: Operating heat pumps at near-freezing temperatures risks damage to the heat exchanger. Heat pumps must be empty of water at freezing temperatures. See winterization guidelines for more details. Verify the ground connection before operation. Improper grounding increases the risk electric shock and death. Grounding protects both swimmers and technicians from electric shock. It is absolutely necessary to properly ground the unit. Heat pumps should be installed outdoors when possible. If necessary, indoor installations must have adequate ventilation and clearance. Keep children away from the heat pump. The lock function can be used to prevent improper operation. Keep fingers and other objects away from the fan. Fan blades are extremely sharp and can cut or damage objects put inside. If you notice any unusual sounds, burning smell, electrical shorts, etc., please immediately disconnect the heat pump and contact Fibropool support. Do not install the unit near any combustible objects or materials. Install the heat pump such that the base rests on a solid, level foundation. When cleaning the unit, the heat pump should be off and disconnected from any power source. III. Installation Instructions 3.1 Installation Diagram *The above diagram may not fit your exact installation. Please contact your pool technician or Fibropool technical support for assistance. 3.2 Installation Clearance Proper clearance is mandatory to allow sufficient airflow and access for maintenance and repairs. 3.3 Additional By-pass kits A bypass is recommended for all installations and is required for pumps larger than 1HP. 3.4 Heat pump unit size (mm) FH235-I FH285-I 3.5 Heat pump Exploded View No. Parts 1 Display 2 Front panel 3 Side panel 4 Pillar 5 Pillar 6 Water flow switch 7 Pressure gauge 8 Sensor clip 9 Fan motor bracket 10 Fan motor 11 Fan blade No. Parts 12 Top frame 13 Bolt 14 Top cover 15 Ventilation 16 Pillar 17 Back frame 18 Evaporator 19 Wire cover 20 Side panel 21 Wire clip No. Parts 22 Wire clip 23 Terminal 24 Pillar 25 Compressor 26 Base tray 27 Four-way valve 28 EEV 29 Titanium heat exchanger 30 Electric box 31 Electric cover 3.6 Electrical connection Model FH235-I FH285-I Terminal Power Cable Specification 12 AWG 12 AWG Terminal cable max. 12 AWG 220-240V/60Hz IV. Technical Speciications 4.1 Specifications Model No. FH235-I FH285-I * Heating Capacity at 80°Air Temp, Humidity 80%, Water 78°in, 82°out Heating Capacity (kW) 7.2~1.7 21~4.8 Power Input (kW) 1.06~0.11 3.09~0.30 COP 15.8~6.8 15.8~6.8 * Heating Capacity at Air 59°, Humidity 70%, Water 78° in, 82°out Heating Capacity (kW) 5.9~1.4 16.5~3.8 Power Input (kW) 1.2~0.18 3.37~0.5 COP 7.6~4.9 7.6~4.9 * Cooling Capacity at Air 95°, Water 84°in, 80°out Cooling Capacity (kW) 4.2~1.0 11.6~2.7 Power Input (kW) 1.11~0.15 3.05~0.4 EER 6.6~3.8 6.7~3.8 * General data Power supply 220-240V/60Hz Max Power Input (kW) 1.45 3.2 Max Current (A) 7.1 14.7 Water Flow Volume (gal/h) 660 1700 Refrigerant R410a Heat Exchanger Titanium Air Flow Direction Vertical Defrost Method 4 way valve Working temp. range (°F) 20~150 Casing Material ABS Water Proof Level IPX4 Noise level 1m dB(A) 41~51 47~58 Noise level 10m dB(A) 21~31 27~38 Net Weight (lbs) 98 135 Gross Weight (lbs) 122 159 Net Dimensions (in) 20.9*20.9*25.2 25.6*25.6*30.3 Package Dimensions (in) 22*23.6*30.7 26.8*28.3*35.8 * Above data may change without notice. V. Electrical Connections 5.1 Electric wiring diagram VI. Heat Pump Operation 6.1 Controller interface 6.2 Start up & Locking Hold the power button for 1 second to switch the heat pump on or off. This button is also used to return back to the main interface. Hold the button for 3 seconds to lock or unlock the display. (The lock will be activated automatically after 60 seconds of inactivity). When the display is locked, the logo appears. Note: Controller will need to be unlocked before changing any settings. Attention: Before you start, make sure the filtration pump is running and that water is flowing through the heat pump. Water flow is required for heat pump to start. 6.3 Temperature Mode Selection From the main screen, press to switch between temperature modes: Auto Heating Cooling *While in Auto mode, if the heat pump is currently heating the display will show cooling mode, the display will show 6.4 Operation Mode Selection and . and . In From the main screen, press to switch between the following operational modes: Silent mode: Limits noise by reducing fan speed. Eco mode: Controls fan speed and compressor output to reduce energy usage. Powerful mode: Highest heating and cooling potential. Note: Auto runs in Eco mode only. Other modes not available. 6.5 Temperature Adjustment From the main screen, press and to adjust the desired water temperature of your pool. When the icon lights up, press the power button 6.6 Clock & Timer setting to save. From the main screen, press and hold and for 3 seconds to enter the clock setting. Press and hold them for 3 seconds again to enter the Timer setting, the will flash. Cancel timer: When you have set the Timer, under the Timer setting interface, hold and for 3 seconds again to cancel the Timer. Clock or Timer setting: To adjust clock or timer settings, change the hours with and , then press the to edit the minutes. Change the minutes with and the setting and return to the main screen. Note: There are 3 individual timers available for separate scheduling. , press to confirm 6.7 Other Icons Water Inlet Water outlet Fan motor Defrosting Wi-Fi Note: On the main screen, the Water inlet temp. and Water outlet temp. will display alternately. 6.8 Manual Defrosting Hold and for 3 seconds to start Manual defrosting function. Note: These heat pumps enter defrost mode automatically when necessary. Contact Fibropool technical support if you encounter frequent defrosting or need to manually enable defrost. 6.9 Restoring Factory settings Hold and and and for 5 seconds to restore factory settings. 6.10 Running Parameter checking Hold for 3 seconds to enter the parameter overview, then press and to check the parameters listed below: Code A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13 A14 Description Inlet water temp. Outlet water temp. Ambient temp. Exhaust temp. Gas return temp. Outer piping temp. Inner piping temp. EEV aperture Compressor current Radiator temp. Voltage value Frequency Fan motor speed Fan motor speed Unit °F °F °F °F °F °F °F A (amps) V (volts) Hz (Hertz) r/min (rotations/minute) r/min (rotations/minute) 6.11 Parameter setting Hold for 3 seconds to enter the Parameter setting, press to select the parameter, then press Code P01 P02 P03 P04 P05 and to set the new data for the below parameters. Description Inlet water temp. in Heating mode Inlet water temp. in Cooling mode Inlet water temp. in Auto mode Water temp. difference before restart Heat pump ON/OFF when reached the desired water temp. Default 27 27 27 1 1 Scope 8~40 8~28 8~40 1~18 1 ON, 0 OFF 6.12 Wi-Fi Setting Hold + Hold + for 5 seconds, enter the mode of intelligent net distribution for 5 seconds, enter the mode of AP net distribution 6.13 Change Display of Temperature from (°C) to (°F) Hold for 5 seconds, if fail, try to hold it for 5 seconds again. When you see the icon is changed, then succeed. Note: When the temperature display is changed, you need to set the Wi-Fi again. VII. Initial Operation 7.1 Attention When first connected, allow water to flow through to purge air from lines. Always inspect electrical connections before operation. Verify that grounding lug is attached to a grounding rod or pool bonding according to local electrical codes. 7.2 Preparation Before Adjustment Ensure the system is installed correctly according to these guidelines. Check that water connections are secure and in the correct positions. Verify supply voltage is sufficient for heat pump operation. Verify adequate ventilation around the unit VIII. Operating Instructions 8.1 To ensure proper operation, frequently inspect water and electrical connections. Follow the guidelines below when performing maintenance or repairs: Always disconnect the incoming power from the breaker or a shutoff switch before opening unit. Unless necessary or instructed by Fibropool, most default settings do not need to be adjusted. Frequently inspect electrical connections for loose or damaged wiring and components. Evaporator fins should be cleaned when dirty or every six months. An air compressor can safely remove most dirt and debris. A damp cloth can be used, but use caution as the fins are sharp and may tear the cloth and cut skin. After long periods of inactivity (after winterization, for example): inspect and clean all equipment, flush plumbing, inspect the pool pump, and recheck and tighten all electrical connections. Aftermarket replacement parts are not recommended and cannot be supported by Fibropool. Visit www.fibropool.com for replacement parts or contact technical support for assistance. 8.2 Draining Heat Exchange When not installed for prolonged periods of time or in anticipation of hard freeze, the heat pump should be completely drained by tilting the outlet at least 45°. A shop vac is recommended to remove any remaining water. Plug the water inlet and outlet before storage to prevent insects and rodents from entering tank. * Warning: A heat exchange cracked due to freezing is not covered under the warranty for this product. It is the homeowner's responsibility to observe proper winterization procedures. See section XI: Maintenance and Winterization for more details. IX. Error Codes and Troubleshooting Code Description Potential reasons Solutions Ensure that water connections are in Insufficient water flow the correct order, that the pump is operating properly, and that all Water flow protection necessary valves are open Check the wiring and reconnect water Water flow switch disconnected flow switch Water flow switch defective Replace flow switch E04 Antifreeze protection Ambient/Inlet water temperature are too low Wait for the ambient/inlet water temperature to increase Ensure that water connections are in Insufficient water flow the correct order, that the pump is operating properly, and that all necessary valves are open Ambient/ Water temperature is Wait for the ambient/inlet water too high temperature to decrease E05 High pressure protection Fan motor speed is abnormal or Inspect fan motor, replace if necessary fan motor is damaged Excess refrigerant gas Drain excess refrigerant* High pressure switch Reconnect or replace high pressure disconnected or defective switch* Verify all plumbing is clear of Plumbing is clogged or jammed obstructions and flowing properly Ensure the heat pump has sufficient Bad ventilation clearance and adequate airflow. Clean the evaporator fins. Verify the fan is running correctly. Low pressure switch Reconnect or replace low pressure E06 Low pressure protection disconnected or defective Gas leakage switch* Verify that the pressure is within acceptable range. Repair leaks* Fan motor speed is abnormal or Inspect fan motor, replace if necessary fan motor is damaged EEV blocked or piping system Verify all plumbing is clear of jammed obstructions and flowing properly Connection failure Bad wire connection Check wire between motherboard and controller E09 between motherboard Defective controller Replace controller and controller Defective motherboard Replace motherboard Communication failure E10 between motherboard and driver module Bad wire connection Defective motherboard Defective Driver module Check wire between motherboard and controller Replace motherboard Replace driver module Ensure that water connections are in Insufficient water flow the correct order, that the pump is operating properly, and that all Excessively high exhaust E12 temperature Low refrigerant Plumbing is clogged or jammed necessary valves are open Check gauge for pressure Verify all plumbing is clear of obstructions and flowing properly Defective exhaust temperature Replace sensor sensor Inlet water temperature Sensor disconnected or E15 sensor failure defective Reconnect or replace sensor Outer piping temperature Sensor disconnected or E16 sensor failure defective Reconnect or replace sensor Exhaust temperature E18 sensor failure Sensor disconnected or defective Reconnect or replace sensor Inverter module E20 abnormal protection Verify all incoming voltage and major electrical components Ambient temperature E21 sensor failure Sensor disconnected or defective Reconnect or replace sensor Ensure that water connections are in Insufficient water flow Overcooling protection in E23 cooling mode the correct order, that the pump is operating properly, and that all necessary valves are open Outlet water temperature sensor failure Replace sensor Outlet water E27 temperature sensor failure Sensor disconnected or defective Reconnect or replace sensor Suction temperature E29 sensor failure Sensor disconnected or defective Reconnect or replace sensor Ensure that water connections are in Insufficient water flow Overheating protection in E32 heating mode the correct order, that the pump is operating properly, and that all necessary valves are open Outlet water temperature sensor failure Replace sensor Piping temp. too high Ambient/water temperature is Verify unit temperature limits E33 protection under cooling too high in cooling mode mode Refrigerant system anomaly Check refrigerant lines* Inner piping temperature Sensor disconnected or E42 sensor failure defective DC fan motor E46 malfunction Bad wire connection Fan motor defective Reconnect or replace sensor Check fan motor wiring Replace fan motor *Any manipulation of the refrigerant or related components must be performed by a qualified technician. Contact Fibropool technical support for assistance. X. WiFi Connection and Operation Scan the QR code below with your phone's camera for step-by-step WiFi connection and operation instructions Hold + for 5 seconds to enter Wi-Fi pairing mode Hold + for 5 seconds to enter Bluetooth pairing mode XI. Maintenance and Winterization · For best performance, we recommend setting the temperature and allowing your heater to run as often as possible. · Clean your pool's filtration system regularly to avoid damage to the unit due to a dirty or clogged filter. · Keep the coils clean by using a foaming air conditioner coil cleaner or pressurized air from an air compressor or air duster. · Winterization: If the unit is not running during winter months, disconnect the power supply and water connections, and drain water from unit by tilting the heater toward the water inlet side at a 45 degree angle. A shop vac can also be used. · Winterization: If possible, store the unit indoors after disconnected to minimize risks of freeze damage or excessive wear due to winter conditions. · After the unit is winterized, it is ideal to cover the unit with a tarp or similar cover. * Warning: A heat exchange cracked due to freezing is not covered under the warranty for this product. It is the homeowner's responsibility to observe proper winterization procedures. FIBROPOOL HEAT PUMP LIMITED FACTORY WARRANTY This warranty certificate applies only to FibroPool brand electric heat pumps Fibropool Co. LLC warrants this Pool/ Spa Heat Pump, to the original owner, to be free of material and workmanship defects for a limited TEN(10) year term. Heat pumps utilizing Fibropool Titanium Heat Exchangers carry a lifetime warranty on the titanium coil tubing. Specific warranty terms are listed below. This warranty will begin on the day of purchase, verified by the homeowner's proof of purchase documents. The full warranty term includes parts and labor charge to remove, repair or replace defective components or failure due to workmanship CLAMS FOR WARRANTY REIMBURSEMENT MUST HAVE PRIOR AUTHORIZATION BY FIBROPOOL and be performed by a qualified person .This warranty does not cover transportation charges for equipment or component parts to and from the factory. PROOF OF PURCHASE REQUIRED FOR WARRANTY COVERAGE This warranty is applicable only if the unit's installation and operation is expressly and completely followed in accordance with the purchase model's Owner / Installation manual. These documents are furnished with each unit and are available by contacting Fibropool Co. LLC. The liability of Fibropool Co. LLC. shall not exceed the repair or the replacement of defective parts under the including refrigerant or transportation to or from the Fibropool Service Center. Fibropool Co. LLC. Is not liable for any damages of any sort whatsoever, including incidental and consequential. This warranty does not include damage to any internal piping or components due to freezing conditions, negligence and abuse, installations in corrosive environments or atmospheres, nor acts of God. There are no implied warranties of merchant ability of fitness for a particular purpose that apply to this product. To obtain warranty authorization, please contact: Fibropool Co. LLC., PO Box 2425, Bay Saint Louis, MS 39521 USA Warranty Schedule: Lifetime parts warranty on titanium tubing heat excharge (plastic tank is excluded) 1 Year Labor on the entire unit 1 Year full on compressor, cabinet, motherboard and digital display 2-10 years prorated warranty on the compressor, cabinet and digit display 1 Year full warranty on all other parts 2-10 years prorated warranty on all other parts PRORATED WARRANTY COVERAGE IS AS FOLLOWS: 0-1 YEAR: 100% 1-2 YEARS: 90% 2-5 YEARS: 50% 5-10 YEARS: 25% Above mentioned warranties apply only to the original purchase. Warranty is non-transferable. Fibropool will have the option to repair or replace the item if found to be defective after inspection. Purchaser is responsible for shipping cost to and from the nearest warranty / repair center. FIBROPOOL WILL NOT BE HELD RESPONSIBLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR CONTINGENT DAMAGE Some states do not allow exclusion of incidental and consequential damages and on how long implied warranty lasts; so above conditions and limitations may not apply to you. This warranty grants you specific rights which may vary from state to state. Email: support@Fibropool.com V2022.04