User Manual for microsonic models including: mic 25 IU TC Mic Ultrasonic Sensors With One Analogue Output, mic 25 IU TC, Mic Ultrasonic Sensors With One Analogue Output, Ultrasonic Sensors With One Analogue Output, Sensors With One Analogue Output, One Analogue Output, Analogue Output, Output

Start here - tr-electronic.microsonic.de

Product description Ԏ The mic sensor with one analogue output measures the distance to an object within the detection zone contactless. A signal proportional to distance is created according to the


File Info : application/pdf, 3 Pages, 629.46KB

PDF preview unavailable. Download the PDF instead.

ba eng mic xxxiu
Operating Manual
mic+ Ultrasonic Sensors with one analogue output
mic+25/IU/TC mic+35/IU/TC mic+130/IU/TC mic+340/IU/TC mic+600/IU/TC

Product description
 The mic+ sensor with one analogue output measures the distance to an
object within the detection zone contactless. A signal proportional to distance is created according to the
adjusted window limits of the analogue characteristic curve.  The sensor automatically detects the load put to the analogue output
and switches to current output or voltage output respectively.  All settings are done with two pushbuttons and a three-digit LED display (TouchControl).  Three-colour LEDs indicate all operation conditions.  Choosing between rising and falling output characteristic is possible.  The sensors are adjustable manually via TouchControl or via Teach-in procedure.

Diagram 1: Set sensor parameters numerically using LED display

 Useful additional functions are set in the Add-on menu.
 Using the LinkControl adapter (op-
tional accessory) and the LinkControl software for Windows®, all
Teach-in and additional sensor pa-
rameter settings can be optionally undertaken.
The mic+ sensors have a blind zone in
which distance measurement is not possible. The operating range indica-
tes the distance of the sensor that can be applied with normal reflectors with sufficient function reserve. When using good reflectors, such as a calm
water surface, the sensor can also be used up to its maximum range. Objects that strongly absorb (e.g. plastic foam) or diffusely reflect sound (e.g.
pebble stones) can also reduce the defined operating range.

Start here
T1 + T2
Press T1 and T2 simultaneously for about 3 s until welcome message has passed.

Set analogue output

T1

T2

T1 + T2

Set sensor-close window

T1

T2 limit in mm or cm.

T1 + T2

T1

T2

Set sensor-distant window limit in mm or cm.

T1 + T2

T1

T2

Choose rising (

) / falling (

output characetistic curve.

)

T1 + T2

Safety Notes  Read the operating instructions
prior to start-up.  Connection, installation and ad-
justment works may only be carried out by expert personnel.  No safety component in accordance with the EU Machine Directive, use in the area of personal and machine protection not permitted
Proper Use mic+ ultrasonic sensors are used for non-contact detection of objects.
Synchronisation If the assembly distance of multiple sensors falls below the values shown in Fig. 1 the integrated synchronisation should be used. Connect Sync/ Com-channels (pin 5 at the units receptable) of all sensors (10 maximum).

mic+25... mic+35... mic+130... mic+340... mic+600...

0.35 m 0.40 m 1.10 m 2.00 m 4.00 m

2.50 m 2.50 m 8.00 m 18.00 m 30.00 m

Fig. 1: Assembly distances, indicating synchronisation/multiplex

Multiplex mode
The Add-on-menu allows to assign an individual address »01« to »10« to each sensor connected via the Sync/ Com-channel (Pin5). The sensors per-
form the ultrasonic measurement sequentially from low to high address. Therefore any influence between the sensors is rejected. The address »00« is reserved to syn-
chronisation mode and deactivates the multiplex mode. To use synchronised
mode all sensors must be set to address »00«.

Installation
Î Assemble the sensor at the installation location.
Î Plug in the connector cable to the M12 connector, see Fig. 2.

2

1

35 4
1 3 4 2 5

+UB ­UB
­ I/U Sync/Com

colour brown blue black white grey

Fig. 2: Pin assignment with view onto sensor plug and colour coding of the microsonic connection cable

Start-up Î Connect the power supply.
Î Set the parameters of the sensor
manually via TouchControl (see Fig. 3 and Diagram 1)
Î or use the Teach-in procedure to
adjust the detect points (see Diagram 2).

cm mm %

Measuring Range
3-digit LED-display LED D1 and D2

T1 D1D2 T2

Push-buttons T1 and T2

Fig. 3: TouchControl/LED display

Factory setting mic+ sensors are delivered factory made with the following settings:  Rising analogue characteristic  Window limits for the analogue
output set to blind zone and operating range  Measurement range set to maximum range
Maintenance mic+ sensors work maintenance free. Small amounts of dirt on the surface do not influence function. Thick layers of dirt and caked-on dirt affect sensor function and therefore must be removed.

Notes
 mic+ sensors have internal temperature compensation. Because the
sensors heat up on their own, the
temperature compensation reaches
its optimum working point after approx. 30 minutes of operation.  If an object is within the set window
limits of the analogue output, then LED D1 lights up green, if the object
is outside the window limits, then LED D1 lights up red.
 The load put to the analogue out-
put is detected automatically when turning supply voltage on.
 During normal operating mode, the
measured distance value is dis-
played on the LED-indicator in mm
(up to 999 mm) or cm (from 100 cm). Scale switches automati-
cally and is indicated by a point on top of the digits. Alternatively a
percentage scale may be set in the add-on menu. In this connection 0 % and 100 % correspond to the
set window limits of the analogue output.  If no objects are placed within the
detection zone the LED-indicator shows »­ ­ ­«.
 The sensor can be set to its factory setting, see Diagram 3.
 If no push-buttons are pressed for 20 seconds during parameter set-
ting mode the made changes are
stored and the sensor returns to normal operating mode.
Show parameters Î In normal operating mode shortly
push T1. The LED display shows »PAr.« Each time you tap push-button T1 the
actual settings of the analogue output are shown.

T1

T2

T1 + T2
Ready

Diagram 2: Set sensor parameters via Teach-in procedure
1

Teach-in analogue output 2

Set window limits
Place object at position 1 .
Press T1 until »IU« is shown.
Current measuring value Place object at position 2 . Current measuring value Press T1 until »End« is shown.

Set rising/falling output characteristic curve
Press T1 until countdown passed from »8 « to »0« and symbol for
rising/falling characteristicis displayed. rising/falling characteristis
falling/rising characteristis To change output characteristic press T1.

Press T1 and T2 simultaneously until »End« is displayed.
Normal operating mode

Diagram 3: Key lock and factory setting

Activate/deactivate TouchControl

Reset to factory setting

Turn supply voltage OFF.

Turn supply voltage OFF.

While pressing T1 turn supply voltage ON.

While pressing T1 turn supply voltage ON.

Keep T1 pressed for about 3 s until »on« or »off« is displayed .
»on« or »off«
/
»off« or »on«
To activate or deactivate press T1.

Keep T1 pressed for about 13 s until »rESEt« has
passed through the display.

Don´t press any push-button for 20 s.

Normal operating mode

Diagram 4: Useful additional functions in Add-on menu (for experienced users only, settings not required for standard applications)

Start here
T1 + T2

Press T1 and T2 simultaneously for about 13 s until »Add« is shown in the LED-display.

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1

T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2 T1

T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T1 + T2

T2

T1

T1 + T2
Ready

»C01«: Display bright
»C02«: Display dimmed
»C03«: Display off

Note Changes in the Add-on menu may impair the sensor function. A6, A7, A8, A10, A11, A12 have influence on the response time of the sensor.

Lower power mode

»­ ­ ­«: Display in mm or cm » «: Display in %, 100 % at minimum measured value » «: Display in %, 100% at maximum measured value
Display mode

»Aut«: automatic detection of the load
»U«: voltage output
»I«: current output

»F00«: no filter
»F01«: standard filter
»F02«: averaging filter
»F03«: foreground filter
»F04«: background filter

Defines the strength of the chosen filter. »P00«: weak filter up to »P09«: strong filter

Delay in seconds between the detection of an object and the output of the measured distance in case of object approach (behaves as on-delay).
"00": 0 s (no delay)
up to
"20": 20 s response time

Minimum value: blind zone
Maximum value: nearwindow limit - 1

»00«: synchronisation
»01« to »10«: sensor address for multiplex mode
»oFF«: synchronisation deactivated

To optimize multiplex speed the highest sensor address may be set.
Setting range »01« to »10«

Choose current/ voltage output

Measurement filter

Filter strength

Response time

Foreground suppression

Multiplex mode device addressing

Multiplex mode highest address

Minimum value: sensor-distant window limit
Maximum value: 999 mm for mic+25/..., mic+35/...,
999 cm for mic+130/..., mic+340/..., mic+600/...

Put plane reflector vertically disposed in front of sensor: in an exact distance of 250 mm for mic+ 25... and mic+35... and 900 mm for all other types.
Adjust display to 250 mm or 900 mm. Confirm calibration with T1+T2.

Affects the size of the detection zone. »E01«: high »E02«: standard »E03«: slight

Measurement range

Calibration display

Detection zone sensitivity

Technical data

mic+25...

mic+35...

mic+130...

mic+340...

mic+600...

M12x1 M12x1 M12x1 M12x1
Ø47.5 M12x1
Ø65

1

2

U

4

5

3

1 analogue output

+UB I/U
Sync/Com ­UB

TouchControl LED-Display

36 width A/F

2 Buttons M30x1.5

5

2 Duo-LEDs

51 84

blind zone 0 to 30 mm operating range 250 mm maximum range 350 mm

angle of beam spread see detection zone transducer frequency 320 kHz
resolution 0.025 to 0.10 mm, depending on the

window limits

detection zones

for different objects:

The dark grey areas represent the

0 cm

zone where it is easy to recognise

the normal reflector (round bar).

This indicates the typical operating range of the sensors. The light

Plate

5 cm

grey areas represent the zone where a very large reflector ­ for instance a plate ­ can still be recognised. The requirement here is for an optimum alignment to the sensor. It is not possible to evaluate ultrasonic reflections outside this area.

10 cm Round bar ø 10 mm
15 cm
20 cm

25 cm

30 cm

35 cm

10 cm 5 cm 0 cm 5 cm 10 cm 20 cm 10 cm 0 cm 10 cm 20 cm 0.8 m 0.4 m 0m 0.4 m 0.8 m 1.6 m 0.8 m 0m 0.8 m 1.6 m 2.4 m 1.2 m 0m 1.2 m 2.4 m

TouchControl LED-Display

36 width A/F

2 Buttons M30x1.5

5

2 Duo-LEDs

51 84
0 bis 65 mm 350 mm 600 mm see detection zone 400 kHz 0.025 to 0.17 mm, depending on the window limits

0 cm

Plate

10 cm

20 cm Round bar ø 10 mm

30 cm 35 cm 40 cm

50 cm

60 cm

TouchControl LED-Display

36 width A/F

2 Buttons M30x1.5

5

2 Duo-LEDs

TouchControl LED-Display

36 width A/F

2 Buttons M30x1.5

5

2 Duo-LEDs

51 84 0 to 200 mm 1,300 mm 2,000 mm see detection zone 200 kHz 0.18 to 0.57 mm, depending on the window limits
0 m

Plate

0.4 m

0.8 m Round bar ø 10 mm

1.2 m 1.3 m

1.6 m

2 m

69 102
0 to 350 mm 3,400 mm 5,000 mm see detection zone 120 kHz 0.18 to 1.5 mm, depending on the window limits

19.5 33

0 m

Plate

0.8 m

1.6 m Round bar ø 27 mm

2.4 m

3.2 m 3.4 m
4 m

4.8 m

5.6 m

TouchControl LED-Display

36 width A/F

2 Buttons M30x1.5

5

2 Duo-LEDs

72 105
0 to 600 mm 6,000 mm 8,000 mm see detection zone 80 kHz 0.18 to 2.4 mm, depending on the window limits

22.5 36

0 m

Plate

1.2 m

2.4 m Round bar ø 27 mm

3.6 m

4.8 m

6 m

7.2 m

8.4 m

reproducibility ±0.15 %

±0.15 %

±0.15 %

±0.15 %

±0.15 %

accuracy ±1 % (Temperature drift internal compensated, may ±1 % (Temperature drift internal compensated, may ±1 % (Temperature drift internal compensated, may ±1 % (Temperature drift internal compensated, may ±1 % (Temperature drift internal compensated, may

be deactivated 2), 0.17%/K without compensation) be deactivated 2), 0.17%/K without compensation) be deactivated 2), 0.17%/K without compensation) be deactivated 2), 0.17%/K without compensation) be deactivated 2), 0.17%/K without compensation)

operating voltage UB 9 to 30 V DC, short-circuit-proof, Class 2 voltage ripple ±10 %
no-load supply current  80 mA housing Brass sleeve, nickel-plated, plastic parts: PBT, TPU;

9 to 30 V DC, short-circuit-proof, Class 2 ±10 %  80 mA Brass sleeve, nickel-plated, plastic parts: PBT, TPU;

9 to 30 V DC, short-circuit-proof, Class 2 ±10 %  80 mA Brass sleeve, nickel-plated, plastic parts: PBT, TPU;

9 to 30 V DC, short-circuit-proof, Class 2 ±10 %  80 mA Brass sleeve, nickel-plated, plastic parts: PBT, TPU;

9 to 30 V DC, short-circuit-proof, Class 2 ±10 %  80 mA Brass sleeve, nickel-plated, plastic parts: PBT, TPU;

Ultrasonic transducer: polyurethane foam,

Ultrasonic transducer: polyurethane foam,

Ultrasonic transducer: polyurethane foam,

Ultrasonic transducer: polyurethane foam,

Ultrasonic transducer: polyurethane foam,

epoxy resin with glass content

epoxy resin with glass content

epoxy resin with glass content

epoxy resin with glass content

epoxy resin with glass content

classofprotectiontoEN60529 IP 67

IP 67

IP 67

IP 67

IP 67

norm conformity EN 60947-5-2

EN 60947-5-2

EN 60947-5-2

EN 60947-5-2

EN 60947-5-2

type of connection 5-pin initiator plug, PBT

5-pin initiator plug, PBT

5-pin initiator plug, PBT

5-pin initiator plug, PBT

5-pin initiator plug, PBT

controls 2 push-buttons (TouchControl)

2 push-buttons (TouchControl)

2 push-buttons (TouchControl)

2 push-buttons (TouchControl)

2 push-buttons (TouchControl)

indicators 3-digit LED display, 2 three-colour LEDs

3-digit LED display, 2 three-colour LEDs

3-digit LED display, 2 three-colour LEDs

3-digit LED display, 2 three-colour LEDs

3-digit LED display, 2 three-colour LEDs

programmable with TouchControl and LinkControl operating temperature ­25 to +70 °C

with TouchControl and LinkControl ­25 to +70 °C

with TouchControl and LinkControl ­25 to +70 °C

with TouchControl and LinkControl ­25 to +70 °C

with TouchControl and LinkControl ­25 to +70 °C

storage temperature ­40 to +85 °C

­40 to +85 °C

­40 to +85 °C

­40 to +85 °C

­40 to +85 °C

weight 150 g

150 g

150 g

210 g

270 g

response time 1) 32 ms

64 ms

92 ms

172 ms

240 ms

time delay before availability <300 ms

<300 ms

<300 ms

<380 ms

<450 ms

order No. mic+25/IU/TC currentoutput4to20mA RL  100  at 9 V  UB  20 V
RL  500  at UB  20 V Rising/falling output characteristic voltageoutput0to10V RL  100 k at UB  15 V, short-circuit-proof Rising/falling output characteristic 1) Can be programmed via TouchControl and LinkControl. 2) Can be deactivated via LinkControl.

mic+35/IU/TC RL  100  at 9 V  UB  20 V RL  500  at UB  20 V Rising/falling output characteristic RL  100 k at UB  15 V, short-circuit-proof Rising/falling output characteristic

mic+130/IU/TC RL  100  at 9 V  UB  20 V RL  500  at UB  20 V Rising/falling output characteristic RL  100 k at UB  15 V, short-circuit-proof Rising/falling output characteristic

mic+340/IU/TC RL  100  at 9 V  UB  20 V RL  500  at UB  20 V Rising/falling output characteristic RL  100 k at UB  15 V, short-circuit-proof Rising/falling output characteristic

mic+600/IU/TC RL  100  at 9 V  UB  20 V RL  500  at UB  20 V Rising/falling output characteristic RL  100 k at UB  15 V, short-circuit-proof Rising/falling output characteristic

microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de / W microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

Enclosure Type 1 For use only in industrial machinery NFPA 79 applications.

The proximity switches shall be used with a Listed (CYJV/7) cable/connector assembly rated minimum 32 Vdc, minimum 290 mA, in the final installation.

Registration no. 75330-19
Approved on June 25th, 2019

*B5398* MV-DO-041945-859292



References

Adobe InDesign 18.5 (Macintosh) Adobe PDF Library 17.0