SmartGen AIN16-PT Marine Engine Controller User Manual
SmartGen AIN16-PT Marine Engine Controller

Introduction

All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.
Smartgen Technology reserves the right to change the contents of this document without prior notice.
If the colors of actual products are different from the manual, please take the actual product as the standard

Software Version. 

DateVersionContent
2014-06-161.0Original release.
   
   

This manual is suitable for AIN16-PT Analog Input Module only.

Clarification of notation used within this publication.

SIGNINSTRUCTION
Warning Icon NOTEHighlights an essential element of a procedure to ensure correctness.
Warning Icon CAUTIONIndicates a procedure or practice, which, if not strictly observed, could result in damage or destruction of equipment.
Warning Icon WARNINGIndicates error operation may cause death, serious injury and significant property damage.

OVERVIEW

AIN16-PT analog input module is an expansion module which has 16 analog input channels and each channel is resistance PT100 input. The data are transmitted to the HMC9000 controller for processing via CANBUS port. Different alarm threshold values can be set for each sensor via HMC9000 controller, enabling module to basically meet all kinds of customer demands.

PERFORMANCE AND CHARACTERISTICS

  • With ARM-based 32-bit SCM, high integration of hardware and more reliable;
  • Must be used with HMC9000 together;
  • CANBUS communication baud rate can be set as 250kbps or 125kbps via dial switch;
  • Module address can be set as 1 or 2.
  • Widely power supply range DC(18~35)V, suitable to different starting battery voltage environment;
  • 35mm rail mounting type;
  • Modular design, pluggable terminal, compact structure with easy installation.
TECHNICAL PARAMETERS
ItemContent
Working VoltageDC18.0V~35.0V    continuous power supply
Power Consumption<0.5W
Sensor typePT100
Measurement accuracy0.5°C
Case Dimension161.6mm x 89.7mm x 60.7mm
Rail Dimension35mm
Working ConditionsTemp.:(-25~+70)°C        Humidity:(20~93)%RH
Storage ConditionsTemp.:(-25~+70)°C
Weight0.33kg
CONNECTION

Connection

No.FunctionCable SizeDescription
1B-1.0mm2DC power supply negative input.
2B+1.0mm2DC power supply positive input.
3CAN(H)0.5mm2A CANBUS port which communicate with HMC9000 controller. 120Ω shielding wire with its one end grounded is recommended.
4CAN(L)
5CH16C0.5mm2PT100 Sensor 16 COM
6BPT100 Sensor 16 terminal
7A
8CH15C0.5mm2PT100 Sensor 15 COM
9BPT100 Sensor 15 terminal
10A
11 

CH 14

C0.5mm2PT100 Sensor 14 COM
12BPT100 Sensor 14 terminal
13A
14 

CH 13

C0.5mm2PT100 Sensor 13 COM
15BPT100 Sensor 13 terminal
16A
17 

CH 12

C0.5mm2PT100 Sensor 12 COM
18BPT100 Sensor 12 terminal
19A
20CH 11C0.5mm2PT100 Sensor 11 COM
21BPT100 Sensor 11 terminal
22A
23CH 10C0.5mm2PT100 Sensor 10 COM
24BPT100 Sensor 10 terminal

AIN16-PT Analog Input Module 

No.FunctionCable SizeDescription
25 A  
26CH 1A0.5mm2PT100 Sensor 1 terminal
27B
28CPT100 Sensor 1 COM
29CH 2A0.5mm2PT100 Sensor 2 terminal
30B
31CPT100 Sensor 2 COM
32CH 3A0.5mm2PT100 Sensor 3 terminal
33B
34CPT100 Sensor 3 COM
35CH 4A0.5mm2PT100 Sensor 4 terminal
36B
37CPT100 Sensor 4 COM
38CH 5A0.5mm2PT100 Sensor 5 terminal
39B
40CPT100 Sensor 5 COM
41CH 6A0.5mm2PT100 Sensor 6 terminal
42B
43CPT100 Sensor 6 COM
44CH 7A0.5mm2PT100 Sensor 7 terminal
45B
46CPT100 Sensor 7 COM
47CH 8A0.5mm2PT100 Sensor 8 terminal
48B
49CPT100 Sensor 8 COM
50CH 9A0.5mm2PT100 Sensor 9 terminal
51B
52CPT100 Sensor 9 COM
 SWITCH HMC9000 can connect to two AIN16-PT modules at the same time.
Address selection: It is module 1 when the switch 1 is connected to terminal 123 while module 2 when connect to ON terminal.
Baud rate selection: It is 250kbps when the switch 2 is connected to terminal 123 while 125kbps when connect to ON terminal.
120Ω resistance selection: There is no matched resistance when the switch 3 is connected to terminal 123 while 120Ω matched resistance has been connected when the switch 3 is connected to ON terminal.
 POWER Power supply indicator and communication status indicator; It
is flashing when the communication is abnormal.

PROTECTION

All data can be protected via HMC9000 controller. HMC9000 can connect to two AIN16-PT modules at the same time and users can select module address via dial switch.
Following parameters can be set via HMC9000:

  1. AIN16-PT module enable: HMC9000 can communicate with the module and collect the AIN16-C data only when the module is enabled;
  2. Alarm threshold and alarm enable of each sensor;

AIN16-PT can collect data only and all alarms are initiated by HMC9000 controller.
HMC9000 will initiate alarm when the sensor value is abnormal. There are two kinds of alarm: warning alarm and shutdown alarm. All alarms are handled by HMC9000 controller only

WARNING 

Warning types are as follows:

No.ItemsRangeDescription
 

1

Sensor 1~16 highFrom “Waiting for load”  delay to “Cooling” delayWhen the controller detects that the sensor 1-16 warning signals, it will initiate a warning alarm and the corresponding alarm information will be displayed on HMC9000 LCD.
2Sensor 1~16 LowFrom “Waiting for load”  delay to “Cooling” delay
3SensorAlways active.
1~16 open 

SHUTDOWN ALARM

Shutdown types are as follows,

NO.ItemsDET RangeDescription
1Sensor 1~16 HighFrom “Waiting for load” delay to “Cooling” delayWhen the controller detects that the sensor 1-16 shutdown alarm, it will initiate a shutdown alarm and the corresponding alarm information will be displayed on HMC9000 LCD.
2Sensor 1~16 LowFrom “Waiting for load” delay to Cooling” delay
PARAMETER CONFIGURATION

AIN16-PT parameters can be set via HMC9000 controller or HMC9000 PC software; more details please refer to specific instruction of HMC9000.

Parameter Configuration List 

ParameterContentsDefault
Module Enable0:Enable
1:Disable
Disable
Sensor 1~16 setSensor types/ Alarm Speed /Range/ High Shutdown Enable / High Shutdown Value / High Shutdown Delay / Low Shutdown Enable / Low Shutdown Value / Low Shutdown Delay / High Warn Enable / High Warn Value / High Return Value / High Warn Delay/ Low Warn Enable / Low Warn Value / Low Return Value / Low Warn Delay For more details please refer to chapter 5.4Sensor type: Temperature Sensor
SENSOR SETTINGS
NO.ItemsContentsRemarks
1Sensor types0:Not Used
1:Oil Pressure Sensor
2:Temperature Sensor
 
2Sensor CurvePT100 
3Alarm Speed(0-200)% 
4Range (current type)(0-6000) 
5High             Shutdown

Enable

0:Enable
1:Disable
 
6High Shutdown Value(0-6000) 
7High Shutdown Delay(0-3600)s 
8Low              Shutdown

Enable

0:Enable
1:Disable
 
9Low Shutdown Value(0-6000) 
10Low Shutdown Delay(0-3600)s 
11High Warn Enable0:Enable
1:Disable
 
12High Warn Value(0-6000) 
13High Return Value(0-6000) 
14High Warn Delay(0-3600)s 
15Low Warn Enable0:Enable
1:Disable
 
16Low Warn Value(0-6000) 
17Low Return Value(0-6000) 
18Low Warn Delay(0-3600)s 
19 User-defined stringUser can reset the sensors’ names which are displayed on HMC9000 LCD. e.g. rename sensor 1 as Temperature sensor. User-defined string can be edited via HMC9000 PC software only.

ELECTRICAL CONNECTIONS

AIN16-PT ELECTRICAL CONNECTION.
Electric Connections 

HMC9000 controller connect with two AIN16-PT module.
Electric Connections

INSTALLATION

Case dimensions:
Dimensions

TROUBLESHOOTING

PROBLEMPOSSIBLE SOLUTION
Controller no response with power.Check batteries;
Check controller connection wirings; Check DC fuse.
CANBUS: Communication
failure
Check if CANBUS wires are connected in the opposite
way.

Customer Support

Smartgen Technology Co., Ltd.
No. 28 Jinsuo Road
Zhengzhou City
P. R. China
Tel: +86-371-67988888
+86-371-67981888
+86-371-67991553
+86-371-67992951
+86-371-67981000 (overseas)
Fax: 0086-371-67992952
Web: http://www.smartgen.com.cn/
http://www.smartgen.cn/
Email: sales@smartgen.cn

Documents / Resources

SmartGen AIN16-PT Marine Engine Controller [pdf] User Manual
AIN16-PT Marine Engine Controller, AIN16-PT, Marine Engine Controller, Engine Controller, Controller, AIN16-PT Marine Engine Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *