Instruction Manual for ESAB models including: Aristo 500ix MIG TIG Stick Welder, Aristo 500ix, MIG TIG Stick Welder, Stick Welder, Welder

ESAB Aristo 500ix MIG TIG Stick Welder 0446200880 Instruction Manual

ESAB

Instruction Manual

Buy ESAB Aristo 500ix MIG TIG Stick Welder 0446200880


File Info : application/pdf, 32 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

ESAB-Aristo-500ix-MIG-TIG-Stick-Welder-0446200880-Instruction-Manual
Aristo® 500ix

Instruction manual
0463 696 201 GB 20221122

Valid for: Serial number: 105-, 243-, 941-xxx-xxxx

TABLE OF CONTENTS

1 SAFETY ...................................................................................................................................... 5

1.1

Meaning of symbols .................................................................................................... 5

1.2

Safety precautions ...................................................................................................... 5

2 INTRODUCTION ......................................................................................................................... 8

2.1

Equipment .................................................................................................................... 8

3 TECHNICAL DATA ..................................................................................................................... 9

4 INSTALLATION........................................................................................................................... 11

4.1

Location........................................................................................................................ 11

4.2

Lifting instructions ...................................................................................................... 12

4.3

Mains supply................................................................................................................ 13

5 OPERATION ............................................................................................................................... 16

5.1

Connections and control devices .............................................................................. 16

5.2

Symbols ....................................................................................................................... 17

5.3

Connection of welding and return cable ................................................................... 17

5.4

Turning the power source on/off................................................................................ 17

5.5

Fan control ................................................................................................................... 18

5.6

Thermal protection ...................................................................................................... 18

5.7

VRD (Voltage Reducing Device)................................................................................. 18

5.8

Remote control unit..................................................................................................... 18

5.9

Arc voltage feedback .................................................................................................. 18

6 MAINTENANCE .......................................................................................................................... 19

6.1

Routine maintenance .................................................................................................. 19

6.2

Power source ............................................................................................................... 20

7 TROUBLESHOOTING ................................................................................................................ 21

8 ORDERING SPARE PARTS ....................................................................................................... 22

ORDERING NUMBERS ......................................................................................................................... 23

BLOCK DIAGRAM................................................................................................................................. 24

ACCESSORIES ..................................................................................................................................... 25

0463 696 201

-4-

© ESAB AB 2022

1 SAFETY
1 SAFETY
1.1 Meaning of symbols
As used throughout this manual: Means Attention! Be Alert!
DANGER! Means immediate hazards which, if not avoided, will result in immediate, serious personal injury or loss of life.
WARNING! Means potential hazards which could result in personal injury or loss of life.
CAUTION! Means hazards which could result in minor personal injury.
WARNING! Before use, read and understand the instruction manual and follow all labels, employer´s safety practices and Safety Data Sheets (SDSs).
1.2 Safety precautions
Users of ESAB equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace. All work must be carried out by trained personnel well-acquainted with the operation of the equipment. Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment. 1. Anyone who uses the equipment must be familiar with:
· its operation · location of emergency stops · its function · relevant safety precautions · welding and cutting or other applicable operation of the equipment 2. The operator must ensure that: · no unauthorised person is stationed within the working area of the
equipment when it is started up · no-one is unprotected when the arc is struck or work is started with the
equipment 3. The workplace must:
· be suitable for the purpose · be free from drafts

0463 696 201

-5-

© ESAB AB 2022

1 SAFETY
4. Personal safety equipment: · Always wear recommended personal safety equipment, such as safety glasses, flame-proof clothing, safety gloves · Do not wear loose-fitting items, such as scarves, bracelets, rings, etc., which could become trapped or cause burns
5. General precautions: · Make sure the return cable is connected securely · Work on high voltage equipment may only be carried out by a qualified electrician · Appropriate fire extinguishing equipment must be clearly marked and close at hand · Lubrication and maintenance must not be carried out on the equipment during operation
WARNING! Arc welding and cutting can be injurious to yourself and others. Take precautions when welding and cutting.
ELECTRIC SHOCK - Can kill
· Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing
· Insulate yourself from work and ground. · Ensure your working position is safe
ELECTRIC AND MAGNETIC FIELDS - Can be dangerous to health
· Welders having pacemakers should consult their physician before welding. EMF may interfere with some pacemakers.
· Exposure to EMF may have other health effects which are unknown. · Welders should use the following procedures to minimize exposure to
EMF:  Route the electrode and work cables together on the same side
of your body. Secure them with tape when possible. Do not place your body between the torch and work cables. Never coil the torch or work cable around your body. Keep welding power source and cables as far away from your body as possible.  Connect the work cable to the workpiece as close as possible to the area being welded.
FUMES AND GASES - Can be dangerous to health
· Keep your head out of the fumes · Use ventilation, extraction at the arc, or both, to take fumes and gases
away from your breathing zone and the general area
ARC RAYS - Can injure eyes and burn skin
· Protect your eyes and body. Use the correct welding screen and filter lens and wear protective clothing
· Protect bystanders with suitable screens or curtains
NOISE - Excessive noise can damage hearing
Protect your ears. Use earmuffs or other hearing protection.

0463 696 201

-6-

© ESAB AB 2022

1 SAFETY
MOVING PARTS - Can cause injuries · Keep all doors, panels and covers closed and securely in place. Have only
qualified people remove covers for maintenance and troubleshooting as necessary. Reinstall panels or covers and close doors when service is finished and before starting engine. · Stop engine before installing or connecting unit. · Keep hands, hair, loose clothing and tools away from moving parts.
FIRE HAZARD · Sparks (spatter) can cause fire. Make sure therefore that there are no
inflammable materials nearby · Do not use on closed containers.
HOT SURFACE - Parts can burn · Do not touch parts bare handed. · Allow cooling period before working on equipment. · To handle hot parts, use proper tools and/or insulated welding gloves to
prevent burns.
MALFUNCTION - Call for expert assistance in the event of malfunction. PROTECT YOURSELF AND OTHERS!
CAUTION! This product is solely intended for arc welding.
WARNING! Do not use the power source for thawing frozen pipes.
CAUTION! Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low-voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility of class A equipment in those locations, due to conducted as well as radiated disturbances.
NOTE! Dispose of electronic equipment at the recycling facility! In observance of European Directive 2012/19/EC on Waste Electrical and Electronic Equipment and its implementation in accordance with national law, electrical and/or electronic equipment that has reached the end of its life must be disposed of at a recycling facility. As the person responsible for the equipment, it is your responsibility to obtain information on approved collection stations. For further information contact the nearest ESAB dealer.
ESAB has an assortment of welding accessories and personal protection equipment for purchase. For ordering information contact your local ESAB dealer or visit us on our website.

0463 696 201

-7-

© ESAB AB 2022

2 INTRODUCTION
2 INTRODUCTION
The power source Aristo® 500ix combined with U6, U82 or MA25 Pulse panels offer a complete multi-process package supporting MIG, pulse MIG, TIG and gouging, depending on which feeder it is used with. The power source is intended for use with the wire feed unit RobustFeed U6, RobustFeed U82, RobustFeed Pulse, Feed 3004/4804 or YardFeed 2000 and the cooling unit COOL 2. For more information about the feed units and the cooling unit, refer to the Instruction information for the specific product. ESAB accessories for the product can be found in the "ACCESSORIES" chapter of this manual.
2.1 Equipment
The power source is supplied with: · 5 m (16 ft) return cable with earth clamp · 5 m (16 ft) mains cable · Instruction manual · Safety instruction manual · Quick start quide

0463 696 201

-8-

© ESAB AB 2022

3 TECHNICAL DATA

3 TECHNICAL DATA

Mains voltage Mains supply Sscmin Primary current Imax MIG/MAG MMA TIG Idle power Setting range (DC) MIG/MAG MMA TIG Permissible load at MIG/MAG 60 % duty cycle 100% duty cycle Permissible load at MMA 60 % duty cycle 100% duty cycle Permissible load at TIG 60 % duty cycle 100% duty cycle Power factor at maximum current Efficiency at maximum current Open circuit voltage Operating temperature Transport temperature Constant sound pressure when idling Dimensions l×w×h Weight Insulation class Enclosure class Application classification

Aristo® 500ix 380-460 V, ±10%, 3~ 50/60 Hz 7.2 MVA

380 V

400 V

38 A 40 A 30 A 24 W

35 A 35 A 27 A 25 W

460 V 30 A 31 A 24 A 27 W

16 A / 14.8 V - 500 A / 39 V 16 A / 20.6 V - 500 A / 40 V 5 A / 10.2 V - 500 A / 30 V

500 A / 39.0 V 400 A / 34.0 V

500 A / 40.0 V 400 A / 36.0 V

500 A / 30.0 V 400 A / 26.0 V 0.91 88 % 58 V -20 to 40 °C (-4 to 104 °F) -20 to 55 °C (-4 to 131 °F) <70 dB (A)
712 × 325 × 470 mm (28.0 × 12.8 × 18.5 in.) 58.5 kg (128.9 lb) H IP23

Mains supply, Ssc min Minimum short circuit power on the network in accordance with IEC 61000-3-12.

Duty cycle The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at a
certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.

0463 696 201

-9-

© ESAB AB 2022

3 TECHNICAL DATA

Enclosure class The IP code indicates the enclosure class, i.e. the degree of protection against penetration by solid objects or water.
Equipment marked IP23 is intended for indoor and outdoor use.
Application class

The symbol hazard.

indicates that the power source is designed for use in areas with increased electrical

Class-H insulations can withstands a temperature of up to 180°C. It is made of inorganic material glued with silicone resin or adhesives of equivalent performance.

0463 696 201

- 10 -

© ESAB AB 2022

4 INSTALLATION
4 INSTALLATION
The installation must be carried out by a professional. The equipment used together with Aristo® 500ix must have at least the following program versions in order for the power source to work properly: · for RobustFeed U82: 3.02G or later · for RobustFeed U6: 2.16P or later · for MA25 Pulse: 1.88H or later
4.1 Location
Position the welding power source such way that its cooling air inlets and outlets are not obstructed.

0463 696 201

- 11 -

© ESAB AB 2022

4 INSTALLATION
4.2 Lifting instructions

0463 696 201

- 12 -

© ESAB AB 2022

4 INSTALLATION
WARNING! Secure the equipment - particularly if the ground is uneven or sloping.
4.3 Mains supply
NOTE! Mains supply requirements This equipment complies with IEC 61000-3-12 provided that the short-circuit power is greater than or equal to Sscmin at the interface point between the user's supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with a short-circuit power greater than or equal to Sscmin. Refer to the technical data in the TECHNICAL DATA chapter.
Make sure that the welding power source is connected to the correct supply voltage and that it is protected by the correct fuse rating. A protective earth connection must be made in accordance with regulations.

1. Rating plate with supply connection data

Recommended fuse sizes and minimum cable area Aristo® 500ix Aristo® 500ix

Mains voltage

380 V 3~ 50/60 Hz

400 V 3~ 50/60 Hz

Mains cable area

4 × 6 mm²

4 × 6 mm²

Maximal current rating Imax

40 A

35 A

I1eff

MIG/MAG

30 A

27 A

MMA

31 A

25 A

TIG

24 A

21 A

460 V 3~ 50/60 Hz 4 × 6 mm² 31 A
24 A 24 A 19 A

0463 696 201

- 13 -

© ESAB AB 2022

4 INSTALLATION

Fuse anti-surge type C MCB

35 A 32 A

35 A 32 A

35 A 32 A

NOTE! The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations. Use the power source in accordance with the relevant national regulations.
Supply from power generators The power source can be supplied from different types of generators. However, some generators may not provide sufficient power for the welding power source to operate correctly. Generators with Automatic Voltage Regulation (AVR) or with equivalent or better type of regulation, with rated power 40 kW, are recommended.
Connection instruction
WARNING! The mains supply must be disconnected during installation.

WARNING! Wait until the DC bus capacitors are discharged. The DC bus capacitor discharge time is at least 2 minutes!
The power source is factory set to 400 V AC. If another mains voltage setting is required, the cable on the printed circuit board has to be moved and put in the correct position. Also the label, at the rear of the power source, marked with the mains voltage setting must be updated. This operation must be done by a person who has the appropriate electrical knowledge.

NOTE! This power source version is designed for a nominal input voltage from 380 to 460 V AC. This means that the hardware to support 575 V input is not available, 575 V tab is not connected.
If the mains cable needs to be changed, the earth connection to the bottom plate and the ferrites must be installed correctly. See the picture below for the installation order of the ferrites, washers, nuts and screws.

0463 696 201

- 14 -

© ESAB AB 2022

4 INSTALLATION

0463 696 201

- 15 -

© ESAB AB 2022

5 OPERATION
5 OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY" chapter of this manual. Read it through before you start using the equipment!
NOTE! When moving the equipment use intended handle. Never pull the cables.
WARNING! Electric shock! Do not touch the workpiece or the welding head during operation!
NOTE! To achieve the best possible result at Mig short pulsing, the welding and return cables must not exceed 10 m (33 ft).
5.1 Connections and control devices

1. Mains power supply switch, O / I 2. Connection for wire feed unit 3. Fuse (10 A) for supply voltage (42 VAC) for
feeder unit 4. Positive welding terminal: Welding cable

5. Negative welding terminal: Return cable 6. Indicating LED, overheating 7. Indicating LED, power supply ON
8. Mains cable inlet

0463 696 201

- 16 -

© ESAB AB 2022

5 OPERATION
5.2 Symbols
Power supply ON (4)
Protective earth

Overheating (3) Positioning of lifting eye

5.3 Connection of welding and return cable

The power source has two outputs, a positive terminal (+) and a negative terminal (-), for connecting welding and return cables.
Connect the return cable to the negative terminal on the power source. Secure the return cable's contact clamp to the work piece and ensure that there is good contact between the work piece and the output for the return cable on the power source.

Recommended maximum current values for connection set cables At an ambient temperature of +25 °C and normal 10 minutes cycle:

Cable area
50 mm2 70 mm2 95 mm2

100% 290 360 430

Duty cycle

60% 320 400 500

At an ambient temperature of +40 °C and normal 10 minutes cycle:

Cable area
50 mm2 70 mm2 95 mm2

100% 250 310 370

Duty cycle

60% 280 350 430

Voltage loss / 10 m 0.35 V / 100 A 0.25 V / 100 A 0.19 V / 100 A
Voltage loss / 10 m 0.37 V / 100 A 0.27 V / 100 A 0.20 V / 100 A

Duty cycle The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at a
certain load without overloading. The duty cycle is valid for 40 °C (104 °F).

5.4 Turning the power source on/off
Turn the power source on by turning switch (1) to the "I" position. Turn the power source off by turning the switch (1) to the "O" position. Regardless the mains supply is interrupted abnormally or the power source is switched off in the normal manner, the welding data will be stored, so it will be available next time the unit is turned on.

0463 696 201

- 17 -

© ESAB AB 2022

5 OPERATION
5.5 Fan control
The power source has a time control that means that the fans continue to run for 6.5 minutes after welding has stopped, and the power source switches to energy-saving mode. The fans start again when welding restarts.
5.6 Thermal protection
The welding power source has thermal protection circuit that operates if the internal temperature becomes too high. If this occurs the welding current is blocked and the indicating LED (6) lights. The thermal protection resets automatically when the temperature has fallen within normal operation temperature.
5.7 VRD (Voltage Reducing Device)
The VRD function ensures that the open-circuit voltage does not exceed 35 V when welding is not being carried out. The VRD function must be activated by a qualified service technician, by means of ESAT (ESAB Software Administration Tool, a kit for technical service including a software to manage settings, update of software etc.). The VRD function is blocked when the system senses that welding has started.
5.8 Remote control unit
For more information about the operation of the remote control unit, see the instruction information for the control panel.
5.9 Arc voltage feedback
To achieve a good welding result, the arc voltage feedback is a crucial factor. In MIG/MAG welding, the power source is prepared to sense the arc voltage in the wire feeder. Prerequisite for this functionality is that an ESAB wire feeder and an ESAB interconnection cable is used! This method of measuring the arc voltage, compensates for the voltage drop in the welding cable to the wire feeder. With an ESAB torch supporting "TrueArcVoltage", the voltage drop all the way to the contact tip is compensated.
NOTE! To compensate the voltage drop in the return cable, the power source can be configured (by authorised ESAB service personnel) to use an external arc voltage sense wire from the workpiece.

0463 696 201

- 18 -

© ESAB AB 2022

6 MAINTENANCE
6 MAINTENANCE

WARNING! The mains supply must be disconnected during cleaning and maintenance.

CAUTION! Only persons with the appropriate electrical knowledge (authorised personnel) may remove
the safety plates.

CAUTION! The product is covered by manufacturer's warranty. Any attempt to carry out repair work by
non-authorised service centers or personnel will invalidate the warranty.

NOTE! Regular maintenance is important for safe and reliable operation.

NOTE! Perform maintenance more often during severe dusty conditions.
Before each use - make sure that: · Product and cables are not damaged, · The torch is clean and not damaged.

6.1 Routine maintenance

Maintenance schedule during normal conditions. Check equipment prior to every use.

Interval Every 3 months

Area to maintain

Every 6 months

Clean or replace unreadable labels.

Clean weld terminals. Check or replace weld cables.

Clean inside equipment. Use dry compressed air with reduced pressure.

0463 696 201

- 19 -

© ESAB AB 2022

6 MAINTENANCE
6.2 Power source
To maintain the performance and increase the lifetime of the power source it is mandatory to clean the product regularly. How often depends on: · the welding process · the arc time · the working environment · the surrounding environment, that is grinding etc.
Tools needed for the cleaning procedure: · torx screwdriver, T25 and T30 · dry compressed air at a pressure of 4 bar · protective equipment like ear plugs, safety glasses, masks, gloves and safety shoes
Cleaning procedure
CAUTION! Make sure that the cleaning procedure is done in a suitable prepared workspace.
CAUTION! The cleaning procedure should be carried out by authorised service technician.

1. Disconnect the mains supply. 2. Wait for 4 minutes to discharge the capacitors. 3. Remove the side panels on the power source. 4. Remove the top panel on the power source. 5. Remove the plastic cover between the heat sink and fan (b). 6. Clean the power source with dry compressed air (4 bar) as follows:
a) The upper rear part. b) From the rear panel through the secondary heat sink. c) The inductor, transformer and current sensor. d) The power components side, from the rear side behind PCB 15AP1. e) The PCBs at both sides.
7. Make sure that there is no dust left on any part. 8. Install the plastic cover between the heat sink and the fan (b) and make sure it is
correctly fitted against the heat sink. 9. Reassemble the power source after cleaning and perform testing according to
IEC 60974-4. Follow the procedure in section "After repair, inspection and test" in the Service manual.

0463 696 201

- 20 -

© ESAB AB 2022

7 TROUBLESHOOTING

7 TROUBLESHOOTING

Try these recommended checks and inspections before sending for an authorised service technician.

Type of fault No arc.

Corrective action
· Check that the mains power supply switch is turned on.
· Check that the mains, welding and return cables are correctly connected.
· Check that the correct current value is set. · Check the mains power supply fuses.

The welding current is interruppted during welding.

· Check whether the thermal protection trip has operated (indicated by the orange LED on the front (6))
· Check the main power supply fuses if the LED indicating power supply (7) is not lit.

The thermal protection trips frequently.

· Make sure that you are not exceeding the rated data for the power source (i.e. that the unit is not being overloaded).
· Check that the ambient temperature is not above the one for the rated duty cycle 40 °C/104 °F.

Poor welding performance.

· Check that the welding current supply and return cables are correctly connected.
· Check that the correct current value is set.
· Check that the correct welding wires are being used.
· Check the main power supply fuses.

0463 696 201

- 21 -

© ESAB AB 2022

8 ORDERING SPARE PARTS
8 ORDERING SPARE PARTS
CAUTION! Repair and electrical work should be performed by an authorised ESAB service technician. Use only ESAB original spare and wear parts.
Aristo® 500ix is designed and tested in accordance with the international and European standards IEC/EN 60974-1 and IEC/EN 60974-10 Class A, Canadian standards CAN/CSA-E60974-1 and US standards ANSI/IEC 60974-1. On completion of service or repair work, it is the responsibility of the person(s) performing the work to ensure that the product still complies with the requirements of the above standards.
Spare parts and wear parts can be ordered through your nearest ESAB dealer, see esab.com. When ordering, please state product type, serial number, designation and spare part number in accordance with the spare parts list. This facilitates dispatch and ensures correct delivery.

0463 696 201

- 22 -

© ESAB AB 2022

APPENDIX
APPENDIX
ORDERING NUMBERS

Ordering number 0446 200 880 0446 200 881 0446 200 882 0446 200 883 0463 696 * 0463 700 001 0460 701 001

Denomination Power source Power source Power source Power source Instruction manual Service manual Spare parts list

Type Aristo® 500ix Aristo® 500ix Aristo® 500ix Aristo® 500ix

Notes CE CSA AUS CCC

The three last digits in the document number show the version of the manual. Therefore they are replaced with * here. Make sure to use a information with a serial number or software version that corresponds with the product, see the front page of the manual.
Technical documentation is available on the Internet at: www.esab.com

0463 696 201

- 23 -

© ESAB AB 2022

APPENDIX
BLOCK DIAGRAM

0463 696 201

- 24 -

© ESAB AB 2022

APPENDIX

ACCESSORIES

Wire feeders 0445 800 894 0445 800 891 0445 800 892 0445 800 887 0445 800 888 0445 800 902 0445 800 897 0445 800 898 0445 800 899 0445 800 900 0445 800 901 0445 800 903

RobustFeed Pulse, water-cooled
RobustFeed Pulse, water-cooled, heater, MMA outlet and flow meter included
RobustFeed Pulse, water-cooled, Push-Pull, heater, MMA outlet and flow meter included
RobustFeed U6, water-cooled, heater, MMA outlet and flow meter included
RobustFeed U6, water-cooled, Push-Pull, heater, MMA outlet and flow meter included
RobustFeed U6, water-cooled, Push-Pull, heater, flow meter, MMA outlet included and VRD activated
RobustFeed U6, water-cooled
RobustFeed U82 offshore, water-cooled, heater, Push-pull, flow meter and MMA outlet
RobustFeed U82, water-cooled
RobustFeed U82 offshore, water-cooled, Push-Pull, heater, flow meter and MMA outlet
RobustFeed U0, water-cooled
RobustFeed U82 offshore, water-cooled, Push-Pull, heater, flow meter, MMA outlet and VRD activated

0463 696 201

- 25 -

© ESAB AB 2022

APPENDIX

0460 526 670 0460 526 671 0460 526 672 0460 526 673 0460 526 886 0460 526 896 0460 526 881 0460 526 891 0460 526 996 0460 526 991 0459 906 896 0465 427 880

Aristo® Feed 3004 MA25 Pulse Al Aristo® Feed 3004w MA25 Pulse Al Aristo® Feed 3004 MA25 Pulse Steel Aristo® Feed 3004w MA25 Pulse Steel Aristo® Feed 3004 U6 Aristo® Feed 3004w U6 Aristo® Feed 3004 U82, (U82 not included) Aristo® Feed 3004w U82, (U82 not included) Aristo® Feed 4804w U6 Aristo® Feed 4804w U82, (U82 not included) Yardfeed 2000w U6, for 200mm (8 in.) spools Cooling unit, Cool2

0349 313 450

Trolley, compatible with RobustFeed and Aristo® Feed 3004

0465 416 880 Wheel kit

0463 696 201

- 26 -

© ESAB AB 2022

APPENDIX

0458 705 880

Counter balance device, for Aristo® Feed 3004 (not RobustFeed)
for 300 mm (11 in.) spools. Includes mast and counter balance For use of the counter balance device, a stabilizer kit is required! IP23 protection is not valid for wire feeder with counterbalance arm!

0465 509 880 Stabilizer kit

Control units 0460 820 880

Aristo® U82, complete including holder

0460 820 881 Aristo® U82 Plus, complete including holder

0463 696 201

- 27 -

© ESAB AB 2022

APPENDIX Aristo® 500ix Weldcloud solution - For detailed instructions, see Assembly Instruction 0446 944 001. 0464 550 800 Weldcloud mobile
0460 891 886 Aristo® W82 Data
0446 712 880 W82 Mounting bracket
0446 877 880 Cable mounting bracket
0462 000 880 12 pol male burndy cable
0446 089 880 Adaptor cable

0463 696 201

- 28 -

© ESAB AB 2022

APPENDIX
Remote controls 0459 491 880 Remote control MTA1

0459 491 896

Remote control unit AT1 MMA and TIG current

0459 491 897

Remote control unit AT1 CF MMA and TIG: course and fine setting of current

0459 491 911 Remote control adapter RA 23

Remote control cable 12 pole - 8 pole 0459 552 880 5 m (16 ft 4.85 in.) 0459 552 881 10 m (32 ft 9.7 in.) 0459 552 882 15 m (49 ft 2.55 in.) 0459 552 883 25 m (82 ft 0.25 in.)
Aristo® Feed 3004 Interconnection cables, gas-cooled, 70 mm², 10 poles 0459 528 780 1.7 m (5 ft 6.93 in.) 0459 528 781 5 m (16 ft 4.85 in.) 0459 528 782 10 m (32 ft 9.7 in.) 0459 528 783 15 m (49 ft 2.55 in.) 0459 528 784 25 m (82 ft 0.25 in.) 0459 528 785 35 m (114 ft 9.95 in.)

0463 696 201

- 29 -

© ESAB AB 2022

APPENDIX
Aristo® Feed 3004 Interconnection cables, water-cooled, 70 mm², 10 poles 0459 528 790 1.7 m (5 ft 6.93 in.) 0459 528 791 5 m (16 ft 4.85 in.) 0459 528 792 10 m (32 ft 9.7 in.) 0459 528 793 15 m (49 ft 2.55 in.) 0459 528 794 25 m (82 ft 0.25 in.) 0459 528 795 35 m (114 ft 9.95 in.)
RobustFeed U6 and RobustFeed Pulse, Interconnection cables with pre-assembled strain relief, gas-cooled, 70 mm2, 10 poles 0446 255 880 2 m (6 ft 6.74 in.) 0446 255 881 5 m (16 ft 4.85 in.) 0446 255 882 10 m (32 ft 9.7 in.) 0446 255 883 15 m (49 ft 2.55 in.) 0446 255 884 20 m (65 ft 7.4 in.) 0446 255 885 25 m (82 ft 0.25 in.) 0446 255 886 35 m (114 ft 9.95 in.) RobustFeed U6 and RobustFeed Pulse, Interconnection cables with pre-assembled strain relief, water-cooled, 70 mm2, 10 poles 0446 255 890 2 m (6 ft 6.74 in.) 0446 255 891 5 m (16 ft 4.85 in.) 0446 255 892 10 m (32 ft 9.7 in.) 0446 255 893 15 m (49 ft 2.55 in.) 0446 255 894 20 m (65 ft 7.4 in.) 0446 255 895 25 m (82 ft 0.25 in.) 0446 255 896 35 m (114 ft 9.95 in.)

0463 696 201

- 30 -

© ESAB AB 2022

APPENDIX

0463 696 201

- 31 -

© ESAB AB 2022

For contact information visit http://esab.com ESAB AB, Lindholmsallén 9, Box 8004, 402 77 Gothenburg, Sweden, Phone +46 (0) 31 50 90 00
http://manuals.esab.com



References

Ibex PDF Creator 4.9.0.16/8438 [.NET 4.0/64]P/R