Installation Guide for DIGITUS models including: DN-65 Industrial Railmount Gigabit Switch, DN-65, Industrial Railmount Gigabit Switch, Railmount Gigabit Switch, Gigabit Switch
Digitus DN-65 Industrial Railmount Gigabit Switch, 16x RJ-45, 2x SFP (DN-651138) od PLN 1377,23 (2024) | Porównanie cen Cenowarka Polska
File Info : application/pdf, 10 Pages, 645.40KB
DocumentDocument16-port 10/100/1000Base-TX +2x Gigabit SFP Industrial Ethernet Switch Quick Installation Guide DN-651138 1. Overview Industrial Ethernet switch with 16-Port 10/100/1000Mbps Base-TX and 2-Port Gigabit SFP, the Product meet CE, FCC, RoHS standards. DN-651138 switch has the operating temperature of -40°C ~ 80°C, has the super firmness can adapt to all kinds of harsh environment, can also be conveniently placed in the compact space of the control box. The installation characteristics of the guide rail, wide temperature operation, IP40 protection class housing and LED indicator light make the DN-651138 a plug and play industrial grade device, providing a reliable and convenient solution for users to network their Ethernet devices. 2. Switch Panel Side panel: P1 and P2 are the number of connecting terminals, and F is the interface of alarm. P+1 and P-1 are respectively to the positive and negative poles to be connected; Earthing screw, used for earthing equipment. Front panel: The Yellow LED on the port is the LINK light, which is on when the connection is established and the data transmission is flashing. 2 The green LED is POE light, which is only on when the switch port is supplying power to PD device (this model is not to support PoE); Power indicator light is on when connecting with Power. Switch size (mm) 3. Features Support long range transmission by fiber optical port. Full working temp. -40 ~ 80 °C to ensure reliable data and long working life In line with industrial operating standards, the average trouble-free work in more than 300,000 hours dual power input Lightning Surge Protection (Power): 5000A (8/20s) DIN Rail and Wall mount support Support full duplex or half duplex mode, with automatic negotiation capability Network port support automatic cross identification internal storage and forwarding mechanism 3 4. Specification 4.1 Standard: IEEE802.310Base-T; IEEE802.3i 10Base-T; IEEE802.3u 100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x 4.2 Interface: 16-Port RJ45; 2- Port SFP Uplink 4.3 Work environment: Working: -40 ~ 80 °C Storage: -40 ~ 80 °C Relative Humidity: 5%~95 % (No condensation) 4. 4 Switch: Bandwidth: 56Gbps Packet Buffer Memory: 4.1Mbit Packet Forwarding Rate: 42Mpps MAC Address Table: 8K 4.5 Power supply: Input voltage: DC12-52V (two-way power redundancy backup) Access terminal: terminal block; Support dual power redundancy Support built-in over current 4.0A protection Support reverse connection protection 4.6 Mechanical characteristic IP40 aluminum housing DIN rail install Natural cooling, no fan Weight: 1.0Kg Measurement: 175.6 x 135 x 45.5 mm 4 4.7 Industrial standard: FCC Part 15 Subpart B, EN55032, Class A IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air) IEC61000-4-3 (RS): 10V/m (80~1000MHz) IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port: ±2kV IEC61000-4-5 (Surge): Power Port: ±2kV/DM, ±4kV/CM; Data Port: ±2kV IEC61000-4-6 (CS): 3V (10 kHz-150 kHz); 10V (150 kHz-80MHz) IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s) Frequency range: 150kHz-80MHz Impact: IEC60068-2-27 Free Fall: IEC60068-2-32 Vibration: IEC60068-2-6 5. Interface Definition 5.1 10/100/1000Base-TX Ethernet interface: This switch provides MDI/MDI-X self-identification with cable support on all 10/100/1000Base-TX ports. In use, the Ethernet port of the switch can be connected with other Ethernet terminal devices through network cables (direct or cross). Please use Class 5 shielded twisted pair. The Ethernet port pin definition is shown in the following figure: RJ45 port supports automatic MDI/MDI-X operation, you can use a straight line to connect to the PC or server, connect to other switches or hubs. In the through line (MDI), pins 1, 2, 3, 4, 5, 6, 7, 8 correspond to the connection; 5 For the MDI-X port of a switch or hub, cross lines are used: 1-3, 2-6, 3-1, 6-2, 4-7, 5-8, 7-4, 8-5.10Base-T/100Base-T (X) pins are defined as follows: Pin No. MDI signal MDI-X signal 1 TX+ RX+ 2 TX- RX- 3 RX+ TX+ 6 RX- TX- 4,5,7,8 - - Note: "Tx ±" refers to send data, "Rx ±" refers to received data ±, and "-" refers to unused data. 5.2 1000base-FX Ehernet interface This device provides 1000Base single-mode dualfiber SC module, and multi-mode like LC, ST as optional. 5.2.1 Patch cord classification According to the transmission mode of light in the fiber, it can be divided into multi-mode fiber and single-mode fiber. Multimode fiber has a thick glass core (50 or 62.5m), which can transmit light in various modes. However, the high inter-mode dispersion limits the frequency at which digital signals can be transmitted, so multimode fibers can be transmitted over relatively close distances (typically only a few kilometers). The single-mode fiber has a very thin glass core (core diameter, usually 9 or 10m) and can transmit only one mode of light. Therefore, it's inter module dispersion is very small, and it is suitable for remote communication. Under normal circumstances, the skin is orange for multi-mode, yellow for single mode. 6 5.2.2 SFP module (Optional, not included) LC connector, Gigabit, 20km Single mode, dual fiber (DN-81011) LC connector, Gigabit, 20km Single mode, Single fiber (DN-81020 and DN-81021) 7 6. LED Indicator LED indicator Status P1/P2 Red LED on Red LED off Yellow LED on RJ45 indicator Yellow LED flashing Yellow/Green LED off Note: this model is not available with PoE Definition Power supplying in normal Power supply abnormal or no powering Network connection in normal Link communication in normal No connection at port 7. Installation caution 7.1 Installation precautions In order to avoid damage to equipment and personal injury caused by improper use, please follow the following precautions: In order to avoid damage caused by falling of the equipment, please put the equipment in a stable environment. When supplying power to the equipment, pay attention to confirm the range of power supply voltage, as well as the positive and negative poles of the power supply, so as not to damage the equipment by wrong operation. In order to reduce the risk of electric shock, ensure that the equipment is well grounded in the working environment. No matter when, please do not arbitrarily remove the equipment shell. When placing the switch, please avoid the area with dust and strong electromagnetic interference 8 7.2 Din rail installation: The first step is to check the grounding and stability of the guide rail: the guide rail slot of the switch is clamped into the guide rail; The second step: from the center to both sides of the guide rail positioning screws in order. Step 3: Use screws to fix the mounting rail card slot on the fixed guide groove at both ends of the guide rail to ensure that the guide rail and the switch are fixed on the guide rail vertically and stably. 7.3 grounding Fix the grounding wire to the grounding screw above the switch, and ensure good reliable connection of the grounding system. 7.4 Power Connection Insert the power cord into the specified position of the 6-core terminal, and insert the terminal into the standard power supply inlet (P+1 and P-1 input corresponding to the first power supply P1, and P+2 and P-2 input corresponding to the second power supply P2). The available voltage standard of the power supply is supported from 12VDC to 52VDC 9 8. Packages Content Industrial switch Quick installation guide Rackmount kit Terminal block QTY 1 PCS 1 PCS 1 SET 1 PCS This is a Class A product. In home environment, this product may cause radio interference. In this case, the user may be required to take appropriate measures. Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address. www.assmann.com Assmann Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid, Germany 10