Instruction Manual for Danfoss models including: FR12 VACON NXP Air Cooled, FR12, VACON NXP Air Cooled, NXP Air Cooled, Air Cooled, Cooled
VACON NXP Air Cooled | Danfoss
File Info : application/pdf, 10 Pages, 1.26MB
DocumentDocumentvacon® nx ac drives ip54 control box installation instructions vacon · 1 index Document code: DPD01614A Date: 1.7.2014 1. CONTENTS OF THE DELIVERY............................................................................................ 2 2. INSTALLATION ................................................................................................................... 3 2.1 Optic fibre cable, signal listing and connections ....................................................................... 5 2.2 Cable bushing diameters ........................................................................................................... 6 24-hour support +358 (0)40 837 1150 · Email: vacon@vacon.com 2 · vacon 1. CONTENTS OF THE DELIVERY 2 1 CONTENTS OF THE DELIVERY 3 5 4 Figure 1. Contents of the IP 54 control box delivery 1 IP54 control box 2 IP54 cable entry grommet plates 3 Grease for the grommet plates 4 Screws (4x10) 5 Plastic pins 1 Tel. +358 (0)201 2121 · Fax +358 (0)201 212 205 INSTALLATION vacon · 3 2. INSTALLATION These instructions guide you through the installation of the IP54 control box that you have purchased for your FR12, FR14, FI12, FI14, CH64 or CH74 size frequency converter. 2. Connect the fibre optic cables. Push carefully the cables into the cellfoam bushings 1. IP54 control box bottom plate with starcoupler board 3. Each fibre optic cable has a number 1...8 and 11...18 marked on the cable shield at both cable ends. Connect each cable to the connectors marked with the same number on the starcoupler board. The list of the optic signals can be found in chapter 2.1 5. Close the cover by pushing it carefully down so that the D-connector connects thoroughly. 6. Attach the cover with four screws (tightening torque 1,5 nm) 4. Connect the 24 V cable and lead it through the bushing as shown in the figure. 7. Apply a thin layer of grease to the cellfoam washers 8. Push the cellfoam washer into the guides in the enclosure. 9. Open the bushing for the cable. Pull away the right size of piece according to the cable size (in this figure 8 mm). 24-hour support +358 (0)40 837 1150 · Email: vacon@vacon.com 2 4 · vacon INSTALLATION 10. Push the cable to the bushing. Make sure that the cellfoam surrounds the cable tightly. 11. Attach the cable to the washer with a plastic binder 12. Apply some grease to the upper cellfoam washer and push it to its place. 13. Attach the seal around the RS485 connector. 14. Attach the cover plate with four screws 15. Seal the holes with a piece of tape and attach the RS485 cable 16. Push the plastic pins to the unused cable entries . 2 Tel. +358 (0)201 2121 · Fax +358 (0)201 212 205 INSTALLATION 2.1 Optic fibre cable, signal listing and connections vacon · 5 Star coupler board on control unit H8 Trip signal from power module 1 H8 H7 VaconBus data from ASIC 1 to control board H7 H6 VaconBus data from control board to ASIC 1 H10 H5 ADC synchronization, power module 1 H6 H11 H4 Phase W control, power module 1 H5 H3 Phase V control, power module 1 H12 H4 H2 Phase U control, power module 1 H13 H1 Gate control enable, power module 1 H3 H2 H18 Trip signal from power module 2 H17 VaconBus data from ASIC 2 to control board H1 H16 VaconBus data from control board to ASIC 2 H15 ADC synchronization, power module 2 H18 H14 Phase W control, power module 2 H17 H13 Phase V control, power module 2 H16 H12 Phase U control, power module 2 H11 Gate control enable, power module 2 H15 H14 H23 Feedback phase W H22 Feedback phase V H13 H21 Feedback phase U H12 H11 H23 H22 H21 Figure 2. Internal fibre cable connections Terminals on ASIC board of power module 1 H1 H1 H2 H2 H3 H4 H3 H5 H4 H6 H5 H7 Gate control enable Phase U control Phase V control Phase W control ADC synchronization VaconBus data from control board to ASIC VaconBus data from ASIC to control board H6 Terminals on FB board of power module 1 H7 H10 Trip signal H11 Feedback phase U H1 H12 Feedback phase V H2 H13 Feedback phase W H3 Terminals on ASIC board of power module 2 H4 H1 H5 H2 H3 H6 H4 H7 H5 H6 H7 Gate control enable Phase U control Phase V control Phase W control ADC synchronization VaconBus data from control board to ASIC VaconBus data from ASIC to control board H10 Terminals on FB board of power module 2 H10 Trip signal 24-hour support +358 (0)40 837 1150 · Email: vacon@vacon.com 2 6 · vacon 2.2 Cable bushing diameters Figure 3. Cable bushing diameter INSTALLATION 2 Tel. +358 (0)201 2121 · Fax +358 (0)201 212 205 Find your nearest Vacon office on the Internet at: www.vacon.com Manual authoring: documentation@vacon.com Vacon Plc. Runsorintie 7 65380 Vaasa Finland Subject to change without prior notice © 2014 Vacon Plc. Document ID: Rev. A Sales code: DOC-INSIP54BOX+DLUK