EVENT-OSVETLITEV-LOGO

EVENT LIGHTING APRO4-IP DMX Controller

EVENT-LIGHTING-APRO4-IP-DMX-Controller-PRODUCT-IMAGE

Zaradi vaše varnosti pred uporabo natančno preberite ta uporabniški priročnik.
Event Lighting si pridržuje pravico, da kadar koli spremeni priročnik. Informacije in specifikacije v tem priročniku se lahko spremenijo brez predhodnega obvestila. Event Lighting ne prevzema nobene odgovornosti za morebitne napake ali opustitve. Za kakršna koli pojasnila ali informacije v zvezi s to postavko se obrnite na Event Lighting.

ZNAČILNOSTI

  • DMX 512, RDM, Artnet and sACN support
  • Oddaljena konfiguracija preko internega webstrani
  • Update firmware on Webstrani
  • DMX output isolation
  • RJ45 Ethernet B input with POE(DC12V 2A)
  • LCD zaslon
  • Gigabit network, 100/1000mbps port speed
  • Ocena IP65

PANEL PREKOVIEW

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (1)EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (2)

  1. Ethernet port RJ45
  2. Ethernet port RJ45
  3. Power in/out True1
  4. 2xDMX5pin connectors
  5. 2xDMX5pin connectors
  6. Nosilec varovalke
  7. LCD Display protection cover

MENIJI
Below is controller Menus map

Glavnimeni Podmeni 1 Podmeni 2 Vrednost/Možnost Privzeto
Omrežje Način IP DHCP Statično
Statično
IP naslov 2.xx.xx.xx 2.xx.xx.xx
Subnet Mask 255.0.0.0 255.0.0.0
Vrata DMX Protokol Artnet Artnet
sACN
Start Net 000-127 000
Zaženi Universe 000-255 000
Vrata 1 Način Izključeno On
On
NET 000-127 000
Vesolje 000-255 000
Vrata 2 Način Izključeno On
On
NET 000-127 000
Vesolje 000-255 001
Vrata 3 Način Izključeno On
On
NET 000-127 000
Vesolje 000-255 002
Vrata 4 Način Izključeno On
On
NET 000-128 000
Vesolje 000-255 003
Onemogoči
nastavitve Stopnja DMX 20Hz 30Hz
25Hz
30Hz
35Hz
40Hz
RDM Onemogoči Onemogoči
Omogoči
Prikaz vklopljen Vedno 1 min
30 sek
1 min
5 min
Izguba signala Drži DMX Drži DMX
Stop Output
Način spajanja PH PH
LTP
Ponastavitev na tovarniške nastavitve št št
ja

WEB konfiguracijo

NET device network IP mode can set to DHCP mode or Static mode.

Način DHCP

  • When APRO4‐IP is set to DHCP mode, you need to set the computer to DHCP also. And use a router for linking computer and APRO4‐IP device. The controller will show IP address like below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (3)
  • Enter IP address in your web browser, then you can login webpage to configure the parameter of controller. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (4)

Vnesite geslo: admin

Statični način

  • When APRO4‐IP device is set to Static mode, you need to set computer to be Static mode also. APRO4‐IP device will show IP address as below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (5)
  • Then set the IP address of computer is in the same IP range manually. For example: IP address must start with 2 according to APRO4‐IP address. And netmask is same with 255.0.0.0. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (6)
  • Input static IP address of APRO4‐IP device in your browser, then you can login to configure the parameter of device.

Vnesite geslo: admin EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (7)

  • When log on NET Config web, the first page show the information about APRO4‐IP. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • Following  is  for  Network  setting,  you  can  set  IP  mode  to  be  Static  or  DHCP,  IP  Address,and Subnet Mask. After setting, click Save button . EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • For DMX Port page , it is used for DMX Port setting. You can select Protocol to be Artnet or sACN, and set each port as input or output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (10)
  • On the page of Setting , you can set DMX Rate, RDM , Display On and Signal Loss. After setting, click Save to store the setting.
  • DMX  Rate:  You  can  set  20Hz,  25Hz,  30Hz,  35Hz,  40Hz,  30Hz  is default setting.
  • RDM: You can set RDM to be Disable or Enable.
  • There is 4 options for Display On mode: Always, 30Sec, 1Min, 5Min.
  • Izguba signala: Can set as Hold DMX or Stop Output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (11)
  • You can return to factory setting by click Factory Reset button. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (12)
  • On Update page, you can update software of fixture by selecting the update software file of APRO4‐IP.
  • On the last page, you can reset password. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (13)

SPECIFIKACIJA

  • Moč: AC 100‐240V,50/60Hz
  • Poraba energije: AC240V 50HZ 0.05A
  • Velikost: 215.3×150.5x42mm 4.2W
  • Teža: 1.43 kg
  • POE 802.3af
  • IP65

DIMENZIJE

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (14)

Garancija

Obrnite se na vašega lokalnega prodajalca ali se obrnite na Event Lighting. www.event‐lighting.com.au

Pogosto zastavljena vprašanja

How do I reset the APRO4-IP device to factory settings?

To perform a factory reset on the APRO4-IP device, access the Factory Reset option in the Main Menu under Settings. Confirm the reset to restore the device to its default configuration.

What is the default IP address for the APRO4-IP device?

The default IP address for the APRO4-IP device is set to DHCP mode. If you switch to Static mode, you can set a specific IP address within the range provided in the user manual.

Dokumenti / Viri

EVENT LIGHTING APRO4-IP DMX Controller [pdfUporabniški priročnik
APRO4-IP, APRO4-IP DMX Controller, DMX Controller, Controller

Reference

Pustite komentar

Vaš elektronski naslov ne bo objavljen. Obvezna polja so označena *