MARTINDALE ELECTRIC TB118KIT1 Complete 
Electrical Safety Kit for Gas Engineers 
User Manual

MARTINDALE ELECTRIC TB118KIT1 ගෑස් ඉංජිනේරුවන් සඳහා සම්පූර්ණ විදුලි ආරක්ෂණ කට්ටලය පරිශීලක අත්පොත

මූලික ලක්ෂණ

  • Complete electrical safety kits for gas installation and service engineers
  • All in one solution for earth verification, locking off and proving dead
  • Includes voltage indicator, proving unit, locking off devices and earth checker
  • Slimline and miniature push pin MCB lock outs and fused spur locking off device
  • Essential for compliance with Electricity at Work Regulations for safe working and TB118

OInv2e0rv1i8ewGagsoeSsahfeerReegister Technical Bulletin 118 was amended. The changes require new test procedures to keep service engineers safe from electrical hazards. Starting from July 2020 Gas Safe registration will require knowledge and competency in how to safely isolate the electrical supply to appliances.

Martindale TB118KIT1 includes all the essential test tools for gas safety engineers to achieve compliance. The new kit combines easy to use tools for live voltage indication and earth loop verification together with fused spur and MCB locking off devices in a high quality soft carry case.
The full kit compromises of:

LOKKITGAS1

  • Four essential locking off devices, LOK10, LOK11, LOK7 for MCBs and LOKFS1 for fused spurs
  • Padlock, pen tag and carry case

VIPD138-S

  • වෙළුමtage indicator and matching proving unit for safe and simple voltagඊ ඇඟවීම
  • Combination carry case

EZ650

  • Earth loop resistance and polarity checker for socket and spur testing

TC88

  •  Soft carry case with shoulder strap

පිරිවිතර

විදුලි
නාමික වෙළුමtage range: 50 – 600V DC/AC rms
නාමික වෙළුමtage threshold indications:
50, 100, 200, 400 V DC/AC rms
වෙළුමtage threshold tolerance:
BS EN 61243-3 ට අනුකූල වේ
Internal impedance at ELV a.c.: 214kΩ
Polarity & voltage indication: ≥ 12V DC/AC rms
ඒසී/ඩීසී වෙළුමtage detection: automatic
Range detection: automatic
ප්‍රතිචාර කාලය: <0.1s
Frequency range: DC, 1 – 400Hz
Test current: < 3.5mA at 600V DC/AC rms
තීරුබදු අනුපාතය: තත් 30 ක් ක්‍රියාත්මකයි (ක්‍රියාත්මකයි) / තත් 240 ක් අඩුයි (ප්‍රතිසාධනය)

පරිසර
Temperature & Humidity (Operating & Storage): -10°C to 55°C ≤
85% RH
උන්නතාංශය: මීටර් 2000 දක්වා

ජනරාල්
Power: From circuit under test
Dimensions: 205(L) x 67(W) x 27(D) mm
බර: 130g පමණ.

ආරක්ෂාව
Conforms to BS EN 61243-3 CAT IV 600 V
II පන්තිය, ද්විත්ව පරිවරණය
පරිසර දූෂණය 2
IP වර්ගීකරණය: IP54

EMC
BS EN 61326-1 ට අනුකූල වේ

PD440S Proving Unit
ප්රතිදාන වෙළුමtage: 440V nominal
Output frequency: 50Hz nominal

පරිසර
Operating temperature: -10°C to 40°C at max. 70% R.H.
උන්නතාංශය: මීටර් 2000 දක්වා
පරිසර දූෂණය: 2

ජනරාල්
Power: internal batteries
Internal batteries: 6 x 1.5V, AA alkaline batteries (IEC LR6, NEDA 15A)
Dimensions: 143 x 84 x 50mm.
Weight packed: 400g approx. with batteries
Includes: 6 x 1.5V AA alkaline batteries, instructions

EZ650 Advanced Socket and Spur Tester
EZ650 E-Ze Check Xtra Pro is supplied with an IEC socket with an interchangeable 3 pin adaptor and a 3 way flying lead with croc clips allowing testing at sockets, fused spurs, light fittings, junction boxes and terminals.

නාමික මෙහෙයුම් පරිමාවtagඊ: 230V
සංඛ්යාතය: 50Hz
Non-trip Earth loop impedance ranges: 0-1.7-5-10-100-200-500Ω
Earth loop threshold accuracy: ±(10% + 0.3Ω)*
වෙළුමtage low indication: <195V ± 5%
වෙළුමtage high indication: >270V ± 5%
Earth neutral voltage high indication: >30V ± 5%
Open earth indication: >500Ω
Temperature Range: -10 to 40°C, non-condensing
මාන: 315mm x 260mm x 85mm
බර: ආසන්න වශයෙන් ඩී
Power supply: From mains
බල පරිභෝජනය: <2.5W
අතිරික්තයtage category: Cat II / 300V
පරිසර දූෂණය: 2
Safety: Complies with BS EN 61010-1

* Note: Measurement accuracy can be affected by highly inductive
or capacitive loads distributed on the supply

LOKKITGAS1 Gas Engineer Lockout Kit
The 8 piece lock out kit contains the following items:

  • 1 x Padlock with unique key (PAD11RD)
  • 1 x Steel safety hasp (LOKHASP25)
  • 1 x Slimline grey isolation lock (LOK7)
  • 1 x Red miniature push pin MCB lock (LOK11)
  • 1 x Yellow push pin MCB lock (LOK10)
  • 1 x “Equipment Locked Out” tag which can be overwritten
  • 1 x Black marker pen (LOKMP)
  • 1 x Soft carry case (TC55)

ඇතුළත්
EZ650 Earth loop impedance & socket tester, LOKKITGAS1 Gas engineer lockout kit, VIPD138-S Voltage indicator & proving unit kit, TC88 Soft carry case

අමතර උපාංග
TAG4 Pack of 10 lock out kit tags

Martindale Electric Co. Ltd.
Metrohm House, 12 Imperial Park,
Imperial Way, Watford WD24 4PP.
T: 01923 441717 F: 01923 446900
www.martindale-electric.co.uk
[විද්‍යුත් ආරක්‍ෂිත]

Ver. C1.0
Due to policy of continuous development, Martindale Electric reserves the right to alter equipment specification and description outlined in this document without prior notice. No part of this document shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. © 2022 Martindale Electric Co. Ltd.

ලේඛන / සම්පත්

MARTINDALE ELECTRIC TB118KIT1 Complete Electrical Safety Kit for Gas Engineers [pdf] පරිශීලක අත්පොත
TB118KIT1 Complete Electrical Safety Kit for Gas Engineers, TB118KIT1, Complete Electrical Safety Kit for Gas Engineers

අදහස අත්හැර