The Reliance Controls PB20 20-Amp NEMA 3R Power Inlet Box is designed to provide a safe and convenient outdoor connection point for portable generators. This unit allows you to hardwire your generator directly to a Reliance Controls transfer switch or panel, eliminating the need to run power cords through windows or doors. Constructed with durable, rain-tight, and rust-proof zinc-plated steel, the PB20 ensures reliable performance in various outdoor conditions. It features an NEMA L14-20P inlet plug, multiple knockout holes for flexible wiring, and push-in wire connections for ease of installation. The removable faceplate further simplifies the wiring process.
ආරක්ෂිත තොරතුරු
අවවාදයයි: Electrical shock hazard. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Failure to follow these instructions may result in serious injury or death.
- Always disconnect power at the source before installing or servicing the power inlet box.
- Ensure the generator is turned off and disconnected before connecting or disconnecting the power cord from the inlet box.
- This power inlet box is for power inlet only, not for use as an outlet.
- Do not operate the generator in an enclosed area. Ensure adequate ventilation to prevent carbon monoxide poisoning.
- Verify that the generator's output matches the power inlet box's rating (20-Amp, 125/250VAC).
- Use only approved and properly rated generator cords.
පැකේජයේ අන්තර්ගතය
ස්ථාපනය ආරම්භ කිරීමට පෙර සියලුම සංරචක පවතින බව කරුණාකර තහවුරු කරගන්න:
- Reliance Controls PB20 Power Inlet Box
- සවි කිරීමේ දෘඩාංග (ඉස්කුරුප්පු, නැංගුරම්)
- ස්ථාපන උපදෙස් (මෙම අත්පොත)
පිරිවිතර
| විශේෂාංගය | විස්තර |
|---|---|
| මාදිලියේ නම | PB20 |
| Amperage ඇගයීම | 20-Amp |
| වෙළුමtagඊ ශ්රේණිගත කිරීම | 125/250VAC |
| NEMA වින්යාසය | L14-20P |
| සංවෘත වර්ගය | NEMA 3R (Rain-tight) |
| ද්රව්ය | Zinc-plated Steel (Rust-proof) |
| මානයන් (LxWxH) | අඟල් 4 x 6 x 8 |
| බර | පවුම් 1.9ක් |
| වර්ණය | අළු |
| සහතික | cUL 1008 Listed |
සැකසුම සහ ස්ථාපනය
සටහන: ස්ථාපනය සිදු කළ යුත්තේ සුදුසුකම් ලත් විදුලි කාර්මිකයෙකු විසින් පමණි.
- ස්ථානයක් තෝරන්න: Select an outdoor location near your transfer switch or panel that is easily accessible for generator connection. Ensure the location is clear of obstructions and allows for proper ventilation.

Image: The Reliance Controls PB20 Power Inlet Box, shown with its protective cover open, revealing the NEMA L14-20P inlet plug. This view highlights the robust construction and the design for outdoor use.
- පෙට්ටිය සවි කරන්න: Securely mount the power inlet box to a sturdy surface using appropriate mounting hardware. The NEMA 3R enclosure is designed for outdoor use, providing protection against rain and sleet.

රූපය: ඉදිරිපස view of the PB20 Power Inlet Box with its protective cover closed, displaying the "RELIANCE" brand name. This illustrates the compact and weather-resistant design when not in use.
- රැහැන් සම්බන්ධතා:
- Remove the face of the box for easy access to the wiring terminals.
- Utilize one of the six knockout holes to bring the conduit or cable into the box.
- Connect the appropriate gauge wires from your transfer switch or panel to the push-in wire connections inside the inlet box. Ensure all connections are tight and secure.

Image: The PB20 Power Inlet Box with its side panel removed, exposing the interior for wiring. This demonstrates the ease of access for making electrical connections.

රූපය: සමීප ඡායාරූපයක් view highlighting the pre-wired built-in grounding feature of the PB20. This ensures proper grounding for safety and simplifies installation by providing easy access to wiring terminals.
- Replace Faceplate: Once wiring is complete and verified, securely replace the faceplate of the power inlet box.
මෙහෙයුම් උපදෙස්
Follow these steps to safely connect and operate your generator with the PB20 Power Inlet Box:
- උත්පාදක යන්ත්රය සකස් කරන්න: Ensure your portable generator is turned off and all loads are disconnected.
- විදුලි රැහැන් සම්බන්ධ කරන්න: Open the protective cover of the PB20 Power Inlet Box. Connect the appropriate generator power cord (NEMA L14-20) to the inlet plug.

Image: The water-tight design of the PB20 Power Inlet Box, demonstrating its ability to protect the inlet from elements like rain. The spring-loaded cover ensures the unit remains sealed when not in use.
- ආරක්ෂිත ආවරණය: Once the cord is connected, ensure the protective cover is properly closed around the cord to maintain weather resistance. The spring-loaded auto-closing cover helps keep the inlet protected from debris and pests when not in use.

රූපය: සවිස්තරාත්මක view of the spring-loaded auto-closing cover mechanism. This feature ensures the inlet is protected from weather, insects, and debris when the generator cord is not connected.
- උත්පාදක යන්ත්රයට සම්බන්ධ වන්න: Connect the other end of the generator power cord to your portable generator.
- උත්පාදක යන්ත්රය ආරම්භ කරන්න: Start your generator according to its manufacturer's instructions.
- මාරු කිරීමේ බලය: Operate your transfer switch or panel to safely transfer power from the utility to the generator.
- විසන්ධි කිරීම: To disconnect, first turn off the generator, then operate the transfer switch to disconnect the generator from the load. Finally, disconnect the power cord from the inlet box and the generator. Close the protective cover on the inlet box.
නඩත්තු කිරීම
The Reliance Controls PB20 Power Inlet Box requires minimal maintenance. Regular inspection and cleaning will ensure its longevity and safe operation.
- වරින් වර පරීක්ෂා කිරීම: Annually inspect the inlet box for any signs of physical damage, corrosion, or loose connections. Check the integrity of the protective cover and ensure it closes properly.
- පිරිසිදු කිරීම: අවශ්ය නම්, පෙට්ටියේ බාහිර පෙනුම දැන්වීමකින් පිරිසිදු කරන්න.amp cloth. Do not use abrasive cleaners or solvents. Ensure the inlet plug area is free of dirt, dust, or debris.
- වෘත්තීය පරීක්ෂාව: It is recommended to have a qualified electrician inspect your entire generator connection system periodically, especially if you notice any irregularities or issues.
දෝෂගවේෂණය
If you experience issues with your PB20 Power Inlet Box, consider the following common troubleshooting steps:
- No Power to Transfer Switch:
- උත්පාදක යන්ත්රය ක්රියාත්මක වන බවත් විදුලිය නිපදවන බවත් සහතික කර ගන්න.
- Check the generator's circuit breakers.
- Verify the generator power cord is securely connected to both the inlet box and the generator.
- Inspect the wiring connections inside the inlet box (only by a qualified electrician).
- Confirm the transfer switch is correctly operated to the generator position.
- Inlet Box Damage:
- If the box or plug appears damaged, do not use it. Contact a qualified electrician for replacement.
- ජල ආක්රමණය:
- Ensure the protective cover is always closed when the unit is not in use or when the generator cord is connected.
- Verify that the mounting surface is flat and the box is securely sealed against it.
For issues not resolved by these steps, consult a qualified electrician or contact Reliance Controls customer support.
වගකීම් තොරතුරු
The Reliance Controls Corporation PB20 20-Amp NEMA 3R Power Inlet Box is covered by a වසර 5ක වගකීමක් from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For specific warranty terms, conditions, and claim procedures, please refer to the warranty documentation included with your product or visit the official Reliance Controls webඅඩවිය.