SHOWVEN Logo

USER MANUAL
SPARKULAR® Cyclone
V2.4
2025/06/16

SHOWVEN BT61 Sparkular Cyclone

Showven Technologies Co., Ltd.

Thanks for choosing SPARKULAR ® Cyclone, we wish it will sparks up your show.
Please read the following manual carefully before operating this product.

SHOWVEN BT61 Sparkular Cyclone - Icon Safety Instructions

\ Unauthorized repair are prohibited, it may cause serious incident.
\ SPARKULAR ® Cyclone can be used in rain, but after use please clean it, and store it at dry environment.
\ Make sure lid of feeding hopper are well covered when use SPARKULAR ® Cyclone.
\ Accidentally burning of consumable can only use sands to extinguish.
\ Consumable should keep away from moisture and stored in a dry sealed environment.
\ Check whether there is consumable aggregate in the output nozzle both before and after each show, if any, please clean it up, or it will affect the firing effect or even damage SPARKULAR ® Cyclone.
\ Please be noted that there may sparks or remains fall to the ground when use HC8600 LARGE, HC8600 LARGE I, HC8600 LARGE II, HC8600 LARGE III. Make sure there is no flammable objects such as carpet on the ground with a radius of 3m close to the machine.
\ Maximum cascade of SPARKULAR ® Cyclone is 2 units with one standard power cable. For 110V version SPARKULAR ® Cyclone, we suggest each machine connect to power supply directly. Otherwise it may damage the machine and even cause fire.
\ For better heat dissipation, block the air intake and air outlet is prohibited.
\ Cover the output nozzle of SPARKULAR ® Cyclone is forbidden, inspect the machine before each show, making sure no objects or material will block the output nozzle.
\ Never touch the nozzle of SPARKULAR ® Cyclone, danger of getting burnt
\ Never touch the sparks which shooting out from the nozzle
\ Ensure that children, animals and unauthorized persons don’t have access to the SPARKULAR ® Cyclone.
Safety Distance
\ Keep audience and flammable material at a minimum distance of 3m from SPARKULAR® Cyclone.
\ Make sure sparks shoot out from SPARKULAR® Cyclone can NOT touch any objects. And keep a clearance with minimum 2m from the setting maximum effect height.
\ In windy environment, increase the safety distance according to the wind direction and speed.
\ The safety zone area changes accordingly when machine installed in tilt position. Please increase the safety distance in the direction which machine tilt.
\ Sparks and consumables from the machine can lead to serious eye injury. Always wear safety goggles when enter the safety zone.

SHOWVEN BT61 Sparkular Cyclone - Description

SHOWVEN BT61 Sparkular Cyclone - Icon Description

SPARKULAR ® Cyclone is a brand new product with SHOWVEN ® original technology. It is with amazing sparks effect up to 10m and equipped with auto brake system, ensure immediate stop even in max output. SPARKULAR® Cyclone with waterproof design allows shows not interrupted by rain. It is designed for the high demanding professional show market makes it an ideal choice for large shows, concerts, music festival, outdoor events etc.

SHOWVEN BT61 Sparkular Cyclone - Icon Technical Specifications

\ Model: BT61/BT62
\ Dimension: 457 370 280mm
\ Weight: 25kg
\ Input: AC 220VAC-240VAC, 50/60HZ; 1700W AC 100VAC-120VAC,50/60HZ; 1700W
\ Work Temp. : -20°C~50°C
\ Effect height: HC8600 LARGE III: 9-10m / HC8600 LARGE II: 8-9m HC8600 LARGE I: 7-8m / HC8600 LARGE: 6-7m
\ Height adjustable: Yes, gear 1~10
\ Effect direction: Straight up
\ Hopper capacity: 500g
\ HC8600 consumption: 75g/min
\ Interface: NEUTRIK POWERCON TRUE1, 3-pin and 5-pin XLR
\ Control: DMX 2 channels

SHOWVEN BT61 Sparkular Cyclone - Icon Structure of SPRKULAR® Cyclone

SHOWVEN BT61 Sparkular Cyclone - Cyclone

  1. Output Nozzle
  2. Feeding Hopper Lid
  3. LCD Screen
  4. Power Switch
  5. Fuse
  6. 5-pin DMX IN
  7. 5-pin DMX OUT
  8. 3-pin DMX IN
  9. 3-pin DMX OUT
  10. POWER IN
  11. POWER OUT

Diagram of Bottom Panel

SHOWVEN BT61 Sparkular Cyclone - Bottom Pane

SHOWVEN BT61 Sparkular Cyclone - Icon Operation Panel

  1. LED display area:SHOWVEN BT61 Sparkular Cyclone - Panel
    READY: Turns from flashing into long on, indicates that the machine is ready to work.
    DMX: Flashing shows that DMX signal is connected; light OFF means there is no DMX signal
    FAULT: Light ON when error occurs
    HEAT: Light ON when system is heating up
  2. Control button area:SHOWVEN BT61 Sparkular Cyclone - Panel 1MENU: Press to switch through menu, press and hold for 3s enter advanced menu
    DOWN: Parameter down
    UP: Parameter up
    ENTER: Confirm and save parameters
  3. RFID area:SHOWVEN BT61 Sparkular Cyclone - RFID area

Composite Ti with RFID card, swiping cards used to identify parameters and types of granules.
The RFID card is disposable, one card can only use one time.

SHOWVEN BT61 Sparkular Cyclone - Icon Interface

  1. Main Interface:SHOWVEN BT61 Sparkular Cyclone - InterfaceFirst Line: shows DMX address
    Second Line: shows inner temp. and temp. progress bar, as well as error info if available.
  2. Error information
    Error informationExplanation
    E0 System ICSystematic error
    E2 Temp. SensorTemperature sensor is not connected or damage
    E3 P Temp. OverChassis over-temperature
    E4 Time RemainActivated time for machine is not enough, please swiping RFID card
    E5 K Temp. OverHeating chamber over-temperature
    E6 Heat FailHeating Fail, if it recovery automatically, problem is shortage of power supply
  3. Setting Menu
    Press “MENU” switch through setup menu.
    OptionsRangeDefaultExplanation
    Set DMX Address1-5121Set DMX address. Each machine occupy two DMX channels. If controlled by Host Controller, please assign a unique address for each machine
    Fountain Height1-105Manual firing height setup, for test only
    Manual HeatON/OFFOFFAuto preheat function switch after turn on machine
    Manual FountainON/OFFOFFManual firing, for test only
    Auto Clear Delay0.1-0.9s0.2sAuto clear material time after each firing
  4. Advanced Menu
    Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key to enter different options, wait 3 seconds to return to the main interface.
    OptionsRangeDefaultExplanation
    Set Temperature400-620580Default is 580. Please don’t change default value without engineer’s suggestion from SHOWVEN®.
    Wireless ControlON/OFFOFFn.a.
    LCD BacklightON/OFFONLCD screen backlight ON/OFF
    Density@ Height 114-9080Sparks density @ Height gear 1
    Density@ Height 214-9080Sparks density @ Height gear 2
    Density@ Height 314-9080Sparks density @ Height gear 3
    Density@ Height 414-10080Sparks density @ Height gear 4
    Density@ Height 514-10080Sparks density @ Height gear 5
    Density@ Height 614-10080Sparks density @ Height gear 6
    Density@ Height 714-10080Sparks density @ Height gear 7
    Density@ Height 814-10090Sparks density @ Height gear 8
    Density@ Height 914-100100Sparks density @ Height gear 9
    Density@ Height 1014-100100Sparks density @ Height gear 10
    Mode SelectionFactory Mode / User ModeUser ModeFactory mode is for engineer only. When in Factory mode machine can’t controlled by DMX console/host controller
    DMX Channel2 / 4 / 2+3
    DMX Channel
    2 DMX
    Channel
    Don’t change. 4 DMX Channel and 2+3 DMX Channel are for special use.
    Standby SwitchON/OFFOFFWhen ON, the machine can firing only when heating up was finished
    BrakingON/OFFOFFWhen ON, blower motor will auto brake when stop firing, frequent braking will leads to over temp.

    For better performance of SPARKULAR ® Cyclone, please don’t change the default value without permission from SHOWVEN ®

  5. DMX Control
    SPARKULAR ® Cyclone occupy 2 channels.
    First channelFunction
    0-15Firing OFF
    16-255Firing ON and with adjustable height
    Second channelFunction
    60-80Clear Material
    20-40Emergency Stop
    0-10Pre-heat OFF (disabled when auto-heat ON)
    240-255Pre-heat ON (disabled when auto-heat ON)

SHOWVEN BT61 Sparkular Cyclone - Icon Operation Guide

  1. Install SPARKULAR ® Cyclone
    a) Horizontal installation is preferred for SPARKULAR ® Cyclone. If need to installed SPARKULAR ® Cyclone in angles, maximum firing angle is 45 ° and can only be angled to the right side as below picture.
    b) Make sure the machine is securely installed to avoid tipping.
    c) The safety zone area shifts accordingly when machine installed in tilt position. Please increase the safety distance in the direction which machine tilt.
    d) Check carefully the output nozzle of each machine, make sure the output nozzle is in good shape and there is no powder aggregate.SHOWVEN BT61 Sparkular Cyclone - SPARKULAR®
  2. Fill SPARKULAR® Cyclone
    a) Open powder bags and fill the feeding hopper. Hopper capacity of SPARKULAR® Cyclone is 500g.
    b) Choose correct consumable according to the application scenario.
    c) Please be noted that there may sparks or remains fall to the ground. Make sure no flammable material on ground in the safety zone.
    d) Maximum effect height: HC8600 LARGE III is 10m, HC8600 LARGE II is 9m, HC8600 LARGE | is 8m and HC8600 LARGE 7m.
    e) Make sure the lid of hopper is locked tight after filling.
  3. Connect Power / DMX cable
    a) Connect a power cable to the POWER IN socket of SPARKULAR® Cyclone. Connect the other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded.
    b) If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine.
    c) The Maximum cascade of SPARKULAR Cyclone is 2 units with one standard power cable. For 110V version SPARKULAR Cyclone, we suggest each machine connect to power supply directly. Do not connect exceed units to a single electrical circuit.
    d) Power ON all SPARKULAR Cyclone.
    e) Assign DMX address for each unit of SPARKULAR® Cyclone. If use SHOWVEN host controller or FXcommander to control the machine please allocate a unique DMX address for each unit of machine.
    f) Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® Cyclone, connect the male connector end of DMX cable to your DMX controller (FXcommander, HOST CONTROLLER, light console etc).
    g) Connect a DMX cable to the DMX OUT of previous machine, and the other end of to the DMX IN of next machine. Connect all devices in series in this way.
    h) Suggest to plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission.
  4. Activate SPARKULAR® Cyclone by swipe RFID card
    a) Swipe an RFID card. Read the card as show below. SPARKULAR Cyclone shows time remain if read successfully.
    b) SPARKULAR Cyclone will report E4 when remaining time is less than 10 minutes.
    c) Please note each RFID card come with 200g package HC8600 can increase single machine 10min working time, the maximum recharge time each time for SPARKULAR Cyclone is 30min, when time remain reached 30min, it can’t recharge anymore RFID card.SHOWVEN BT61 Sparkular Cyclone - RFID card
  5. Programming and Firing
    a) Programming SPARKULAR® Cyclone, set the firing height, firing sequences etc.
    b) Heating up machine, it takes around 5min. it various according to the voltage and environment temperature.
    c) Make sure the prescribed safety zone is clear.
    d) Suggest to clear material before firing.
    e) Firing. In order to prevent overheat in the heating chamber and protect machine, the maximum continuous firing time for SPARKULAR® Cyclone is 30s.
    f) The operator should always have a clear view of the device, so that he/she can stop the show immediately when there is danger.
    g) Clear material for SPARKULAR® Cyclone for 5s after show, clear material will remove the remaining particles from heating chamber. For angled installation, please elongate clear material time.
  6. Turn off and Clean up
    a) Power off SPARKULAR® II, allow SPARKULAR® Cyclone to cool down.
    b) Disconnect all POWER and DMX cables.
    c) Empty the remaining HC8600 in hopper, and store the remaining HC8600 in a dry sealed bottle for next time use. Never touch the output nozzle of SPARKULAR® Cyclone when empty the hopper. DANGER OF GET BURNT!
    d) Operators can use handheld vacuum cleaner to empty the feeding hopper. Do make sure the machine was cool down when clean it. Do NOT use high-power vacuum cleaners to avoid hot consumables being sucked into the vacuum cleaner from the heating chamber and cause fire.
    e) Clean the surroundings to remove powder residues.

SHOWVEN BT61 Sparkular Cyclone - Icon Maintenance

  1. Empty the feeding hopper before shipment of machine.
  2. Empty the feeding hopper if long time not use, for high humidity environment we suggest to empty feeding hopper after each show.
  3. Clear material both before and after the show.

SHOWVEN BT61 Sparkular Cyclone - Icon Warranty Instructions

\ Sincere thanks for your choosing our products, you will receive quality service from us
\ The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you.
\ We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period.
Please don’t repair machine without factory permission
Below situations NOT included in warranty service:
\ Damage caused by use other type of consumable which is not originally from SHOWVEN®.
\ Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
\ Disassemble, modify or repair products without permission;
\ Damage caused by external reasons (lightning strike, power supply etc.)
\ Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service.
Invoice is necessary when applying for maintenance service from SHOWVEN®.

SHOWVEN BT61 Sparkular Cyclone - Qr Codehttps://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour

Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn
E-mail: info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, Changsha, Hunan,
410300, P.R.China

Documents / Resources

SHOWVEN BT61 Sparkular Cyclone [pdf] User Manual
BT61, BT62, BT61 Sparkular Cyclone, BT61, Sparkular Cyclone, Cyclone

References

Leave a comment

Your email address will not be published. Required fields are marked *