The mains supply is connected into a switch mode power supply (separate from your DP700) via a
detachable supply cord supplied. If another supply cord is used, it must have fitted a C5, 10A, EARTHED mains connector with a cord rated for at least 10A.
If a mains plug is not already fitted to the supply cord or is of the wrong type, then a suitable EARTHED plug should be used which complies with the relevant specifications for plugs and socket outlets.
You can only use the DP700 with Newall Spherosyn and Microsyn analogue encoders.
Unit only to be serviced by Newall qualified personnel or authorised alternatives.
Turn off the power by disconnecting the power supply connector before you connect the encoder(s)

Technical Specification

Environmental
Operating Temperature Storage Temperature
-10°C to 50°C -20 to 70°C
Environmental Conditions – IP40 (Stand Alone) IP54 (Panel Mount)
Relative Humidity – maximum 95% for temperature up to 31°C
Disposal
At the end of it’s life, you should dispose of the DP700 in a safe manner applicable to electronic goods.
The case work is suitable for recycling. Please consult local regulations on disposal
Electrical
EU Directive 73/23/EEC (Low Voltage
Directive)
BS EN 55022:1998 Class B
BS EN 55024:1998
Input to Power Supply Unit (Supplied)
100-240V (47-63Hz)
External switch-mode
Output voltage 15VDC
Input Voltage to DP700
15-24VDC ±10%
Conforms to Low Voltage Directive
Note: Newall Measurements Systems reserves the right to change specifications without notice.
Connections
Connection
Understanding the Keypad
Connection

Axis Selection KeyConnectionNumeric KeysConnectionEnter KeyConnectionClear Numeric EntryConnection
Center FindConnectionUndo KeyConnectionDigifind / ReferenceConnectionSwitches between Zero and Axis Preset modesConnection
Switches between Absolute and Incremental modesConnectionSwitches between Inch and mm displayConnectionInformation selection (scrolls through options on Message display)ConnectionFunction Menu KeyConnection
Function Navigation KeysConnectionSleep keyConnection

Zero an Axis in Zero Mode
Ensure DP700 is in Zero Mode
Connection
of Axis 1, 2 or 3
Zero an Axis in Set Mode
Ensure DP700 is in Set Mode
Connection
Preset an Axis
Ensure DP700 is in Set Mode
Connection
ENTERING SETUP
Connection
Until display shows
Connection
display shows
Connection

SETTING UP THE UNIT
Connection

Must be set to match encoders on the machine

AMERICAS Newall Electronics Inc. 1803 OBrien Rd Columbus, OH 43228
Tel: +1 614 771 0213
sales@newall.com
newall.com
REST OF WORLD
Newall Measurement Systems,Ltd. Business Park, Unit 1 Wharf Way Glen Parva, Leicester LE2 9UT
United Kingdom
Tel: +44 (0) 116 264 2730
sales@newall.co.uk
newall.co.ukCompany Logo

Documents / Resources

Sensata DP700 MK2 Digital Readout System [pdf] User Guide
DP700 MK2 Digital Readout System, DP700, MK2 Digital Readout System, Digital Readout System, Readout System, System

References

Leave a comment

Your email address will not be published. Required fields are marked *