Instruction Manual for LEDALITE models including: ID-23 Tru Groove Recessed Micro, ID-23, Tru Groove Recessed Micro, Groove Recessed Micro, Recessed Micro
TruGroove recessed micro - Recessed | Ledalite - Signify
File Info : application/pdf, 8 Pages, 1.91MB
DocumentDocumentLinear TruGroove Recessed Micro ID-23 T-Grid Installation Instructions Standalone or Continuous Run in T-Grid Ceiling These instructions review how to install TruGroove recessed micro fixtures in T-Grid ceilings. For continuous run lengths, Please refer to layout drawings supplied by Ledalite in conjunction with these installation instructions. The graphics below show the components required to install a run of TruGroove fixtures in T-Grid ceilings. IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation Drop Lens Endcap Kit(s)* · Drop Lens Endcap (x1) · Screws (x2) *Optional NOTE: One kit required for each end. Module 1 Module 2 Flush Lens Asymmetric direction of light Symmetric direction of light 1" Drop Lens · Exterior flush and drop lens kits -variable lengths (shipped separately) Note: Louver optics ship factory installed. i Hanger Kit(s) ii Joint Kit(s) · Bracket (x4) · Screws (x8) NOTE: One kit required for each module. Tools required: Phillips screwdriver, 5/16" nut driver. · Joiner Aligners (x2) · Joiner Brackets (x2) · Hex Bolts (x4) · Screw(s) ( x1 symmetric, x2 for asymmetric ) · LED pan connectors (x1) NOTE: Image shown is a symmetric connector. Asymmetric has two pieces. NOTE: One (1) kit required for each module joint in continuous runs ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 1 Rev E. www.ledalite.com ID-23 TruGroove Recessed Micro T-Grid Installation Instructions This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Important Notes Warning, Shock Hazard Fixture must be connected to building ground via the provided ground wire before connecting to mains power supply. Disconnect or turn off power before attempting any installation, service or maintenance. i Prepare Fixtures Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings. Remove fixtures from boxes. Remove plastic from fixtures. Match up each fixture and lens based on the spec tag and ID number labelled on each fixture box for the specified run. 1 T-Grid 2.88" (73mm) Install Fixtures 2 Install Mounting Brackets 9/16 Grid 1 3/4 Height 9/16 Grid 1 11/16 Height 9/16 Grid 1 1/2 Height 9/16 Grid 1 1/16 Height - 5/16 Tegular 9/16 Grid 1 1/2 Height - 5/16 15/16 Grid 1 11/16 Height 15/16 Grid 1 1/2 Height 15/16 Grid 1 3/8 Height 15/16 Grid 1 3/16 Height Install main tees, 2.88" on center. For continuous row lengths, refer to supplied layout drawings. Add 1/4 " to the overall housing length indicated on your layout drawings. Position and secure the cross tees. Install Fixture Above 3 T-Bar Grid Important: Install T-Grid mounting brackets to required height. Install the first fixture (or Standalone Unit) from above the T-Bar Grid. ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 2 ID-23 TruGroove Recessed Micro T-Grid Installation Instructions NOTE: For Standalone fixtures skip to step 8 4 Install Joiner Aligners Dimple engaged Complete Wiring and 5 Connect Fixtures Open Slots for Joiner 6 Brackets In the joining fixtures install the joiner aligners in the trim extrusion just past the halfway point. Important: To insert aligners, tap gently with a hammer until middle dimple is fully inserted into the joiner channel. Be sure to engage the dimple as shown. 7 Install Joiner Brackets Install the joiner fixture into the T-Bar Grid from above. Complete wiring and slide the fixtures together. 8 Secure Fixture on the Grid Snap off the safety cover on joiner brackets slots with a flat head screw driver. This only needs to be done one sides that require joining. 9 Install Power Drop Install supplied joiner brackets with 5/16" nut driver. Secure the fixture to T-bar grid. For continuous runs, finish installing run first and then secure to the T-bar grid. Install power drop at desired location. At power location(s), remove factory installed wire cover. Feed power wires through. Complete all wiring connections using wire nuts supplied by others. ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 3 ID-23 TruGroove Recessed Micro T-Grid Installation Instructions Install CAT6 Cables for 9a POE Option 10 Install Wire Access Cover 11 Install Seismic Restraints Install CAT6 cables and desired location. Install wire access cover to close the fixture. Install seismic restraints according tolocal building code requirements. 12a LED Pan Joiner - Symmetric 12b LED Pan Joiner - Asymmetric 13 Install Drop Lens Endcap Mount the LED pan connector with the supplied screw in the joiner kit. Note: This step is not required for louvers. Mount the LED Pan connector with the supplied screw in the joiner kit. There are two pieces for asymmetric fixtures. Note: This step is not required for louvers. Flush Push up drop lens endcap flush to bottom of trim while hand tightening with supplied screws.(8-18 x 3/8 Pan) ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 4 www.ledalite.com ID-23 TruGroove Recessed Micro T-Grid Installation Instructions 14 15 Fixture Lens Installation 16 Fixture Lens Installation Snap in lens into fixture. Note: Flush lens and drop lens are installed the same way. Flush lens is shown for reference. Standalone Units: Lenses are supplied in 2', 3', 4', 5', 6' or 8' lengths. Continuous Runs: Lenses are pre-cut to a maximum of 8' lengths and are specific to run lengths. Consult layout drawings for placement. Installed lenses are removed in step 1. Installation Tip: For easier installation, start at a housing end or a joint by placing lens at an angle and squeezing in slightly from the other side to guide inside housing. Once lens is positioned inside housing, starting on one end or joint, push upwards gently and work outward to complete the run. Partially installed Fully installed ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 5 www.ledalite.com ID-23 TruGroove Recessed Micro T-Grid Installation Instructions ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 6 www.ledalite.com ID-23 TruGroove Recessed Micro T-Grid Installation Instructions Sensors in Rows Single Sensor Controlling Whole Row 1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures. Note: · A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory. Alternate Integral Sensor 1 Remote Sensor 4ft Bottom view of fixtures 8ft Multiple Sensors Controlling Separate Zones in a Row 2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones. Notes: · A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory. · Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app). Alternate Remote Sensor Integral Sensor Zone 1 8ft 2 Integral Sensor Zone 2 Bottom view of fixtures 4ft Sensor Spacing · For correct operation, sensors should be placed a minimum distance of 8ft apart. · Wireless sensors should be placed no further than 40ft apart for good wireless signal connection. Alternate Remote Sensor Integral Sensor 4ft Integral Sensor Bottom view of fixtures Sensors too close 8ft for correct operation. Alternate Remote Sensor Integral Sensor Sensor Zone 1 8ft Integral Sensor Zone 2 Bottom view of fixtures Sensors at minimum 4ft required distance for correct operation. Integral Sensor 40ft Max. Bottom view of fixtures Sensors at a maximum distance of 40ft apart. Important Consideration When Using Sensors in a Row Alternate Remote Sensor · For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch. · For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens. · For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same wiring rules will apply. ! ATTENTION: Install in accordance with national and local building and electrical codes. 10/31/2023 page 7 www.ledalite.com ID-23 TruGroove Recessed Micro T-Grid Installation Instructions Occupancy Sensor Coverage: Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire. The detection area for the movement sensor can be roughly divided into two parts: · Minor movement (person moving 3ft/s or 0.9m/s). · Major movement (person moving 3ft/s or 0.9m/s). Daylight sensor The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation: · Minimum distance from the window 2ft (0.6m). · Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation. As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor. Photosensor spatial response ! ATTENTION: Install in accordance with local and national building and electric codes. 10/31/2023 page 8 www.ledalite.com www.signify.com