Instruction Manual for Met One models including: 102902-9800 Upgrade Weather Station, 102902-9800, Upgrade Weather Station, Weather Station, Station
Support Archive - Met One Instruments
TACMET II TRV Upgrade User Manual - 102902-9800 Rev B - Met One Instruments
File Info : application/pdf, 15 Pages, 202.28KB
DocumentDocumentTACMET II, TRV, UPGRADE WEATHER STATION OPERATION MANUAL Met One Instruments, Inc Corporate Sales & Service: 1600 NW Washington Blvd. Grants Pass, OR 97526 Tel (541) 471-7111 Fax (541) 471-7116 www.metone.com service@metone.com 102902-9800 TACMET II, TRV, Upgrade Manual Rev B ISO 9001:2015 Certified Technical Support Should you require support, please consult your printed documentation or our website www.metone.com to resolve your problem. If you are still experiencing difficulty, you may contact a Technical Service representative during normal business hours; Monday Friday 7:00 a.m. to 4:00 p.m. Pacific Time. Voice: (541) 471-7111 Fax: (541) 471-7116 E-Mail: service@metone.com Mail: Technical Services Department Met One Instruments, Inc. 1600 NW Washington Blvd Grants Pass, OR 97526 102902-9800 Operation Manual ISO 9001:2015 Certified 2 Revision B, 10/3/2024 Safety Notice The contents of this manual have been checked against the hardware and software described herein. Since deviations cannot be prevented entirely, we cannot guarantee full agreement. However, the data in this manual is reviewed regularly and any necessary corrections are included in subsequent editions. Faultless and safe operation of the product presupposes proper transportation, storage, and installation as well as careful operation and maintenance. The seller of this equipment cannot foresee all possible modes of operation in which the user may attempt to utilize this instrumentation. The user assumes all liability associated with the use of this instrumentation. The seller further disclaims any responsibility for consequential damages. Electrical & Safety Conformity The manufacturer certifies that this product operates in compliance with the following standards and regulations: FDA/CDRH This product is tested and complies with 21 CFR, Subchapter J, of the Health and Safety Act of 1968 US 21 CFR 1040.10 FCC Notices Contains FCC ID: OUR-XBEE/OUR-XBEEPRO* The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT: The RF module has been certified for remote and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 102902-9800 Operation Manual ISO 9001:2015 Certified 3 Revision B, 10/3/2024 If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: re-orient or relocate the receiving antenna, increase the separation between the equipment and receiver, connect equipment and receiver to outlets on different circuits, or consult the dealer or an experienced radio/TV technician for help. RF Exposure WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. Warranty All instruments are warranted against defects in parts or workmanship for a period of one (1) year from the date of shipment. Should any instrument or part prove to be defective within the warranty period, upon written notice and return of the unit (freight prepaid), Met One Instruments, Inc. will, at its option, repair or replace the defective unit, and return it, transportation prepaid via surface transportation. Equipment abused, modified, or altered may cause cancellation of this warranty. The above warranty applies only to items manufactured by Met One Instruments, Inc. Items not manufactured by Met One Instruments, Inc. are warranted only to the extent and in the manner warranted by the manufacturer of such items. Should emergency warranty repair be required at a customer's facility, Met One will provide such repairs and charge only the portal-to-portal Field Service rates and actual expenses in accordance with our published rates then in effect. Expendable supplies and wear items, such as bearings and lightning related damage, are not covered under this warranty. 102902-9800 Operation Manual ISO 9001:2015 Certified 4 Revision B, 10/3/2024 Table of Contents 1.0 Safety...................................................................................................................... 6 2.0 Introduction & Overview ................................................................................... 7 2.1 Overview ............................................................................................................ 7 2.2 Specifications................................................................................................... 7 3.0 Installation ............................................................................................................ 9 4.0 Input/Output Connections ................................................................................ 9 5.0 User Interface ..................................................................................................... 10 6.0 Calibration........................................................................................................... 11 7.0 Maintenance ....................................................................................................... 11 Appendix A - Terminal Mode Commands.............................................................. 12 Appendix B - Theory of Operation........................................................................... 15 102902-9800 Operation Manual ISO 9001:2015 Certified 5 Revision B, 10/3/2024 1.0 Safety 1.1 Safety This manual may include a CAUTION and a WARNING indication. Familiarize yourself with the following definitions for the meanings of these indicators. A CAUTION indicates a hazard and calls attention to a procedure that if not correctly followed could result in damage to the instrument. Do not proceed beyond a caution indicator without understanding the hazard. A WARNING indicates a hazard to you and calls attention to a procedure that if not correctly followed could result in injury or even death. Do not proceed beyond a warning without understanding the hazard. 102902-9800 Operation Manual ISO 9001:2015 Certified 6 Revision B, 10/3/2024 2.0 Introduction & Overview 2.1 Overview Met One's TACMET II, TRV, Upgrade Weather Station is designed as a standalone weather station to provide accurate measurements of wind speed, wind direction, temperature, relative humidity, and barometric pressure. The TRV, Upgrade Weather Station has a built-in 2.4 GHz spread spectrum radio module with 128-bit data encryption (XBeePro). The unit has no moving parts and is ideally suited for use wherever reliable, maintenance free operation over a wide operating range under adverse operating conditions is required. The unit is built with a metal housing to offer some protection from electromagnetic interference. The TACMET II TRV, Upgrade Weather Station is painted CARC tan. 2.2 Specifications PERFORMANCE Wind Speed Range Accuracy * Resolution Wind Direction Range Accuracy * Resolution Temperature Range Accuracy Resolution Relative Humidity Range Accuracy Resolution Barometric Pressure Range Accuracy Resolution 0-65 m/s (0-145 mph) 0.5 m/s (1.1 mph) 5% 0.1 m/s (0.22 mph) 0 to 360 5° @ wind speeds > 2.2 m/s (5 mph) 1 -40° to 60C (-40° to +140F) 2C ( 3.6F) @ WS>2.0 m/s (4.5 mph) ± 0.1°C 0 to 100% 3% 1% 500 to 1200 hPa (14.75 to 35.50 in Hg) 0.40 hPa (±0.01 in Hg) 0.1 in Hg MTBF 80,000 hours * This accuracy is maintained when the sensor is within 10 degrees of vertical. 102902-9800 Operation Manual ISO 9001:2015 Certified 7 Revision B, 10/3/2024 ELECTRICAL Measurement Format Measurement Rate Operating Frequency Signal Output Power Requirements Two orthogonal axis, North-South and East-West Approx. 2 Hz each axis 40 kHz RS232 @19.2 K baud (see section 5.0) 9 - 36 Vdc: 100 mA draw @ 12 Vdc PHYSICAL Size Weight Mounting Finish Color 12.25 inches (31.1 cm) x 4 inches (10.15 cm) dia. 5.5 lb. (2.5 kg.) MS3106F18-1S Connector per MIL-DTL-64159 CARC TAN 686A, 33446 102902-9800 Operation Manual ISO 9001:2015 Certified 8 Revision B, 10/3/2024 3.0 Installation Be sure to mount the TACMET II, TRV, Upgrade Weather Station in a clear, open area to minimize any turbulent effects caused by local obstructions (e.g., trees, buildings, etc.). The TACMET II, TRV, Upgrade Weather Station is installed on the Met One P/N 102709 pre-wired Quick Mount. The keyway in the connector on the base of the TACMET II, TRV, Upgrade Weather Station is matched to the keyway on the mount. Attach the TACMET II, TRV, Upgrade Weather Station to the 102709 Quick Mount by inserting it into the top of the mount, aligning the latch springs with the clips on the bottom of the sensor. It may be necessary to rotate the TACMET II, TRV, Upgrade Weather Station 180° to allow the keyway to seat properly. When the sensor is properly seated in the mount, attach the latch springs to the clips on the sensor and snap them down to lock the sensor in place. The TACMET II, TRV, Upgrade Weather Station is supplied with an internal fluxgate compass to automatically orient the wind direction data to magnetic North. True North is calculated by the sensor if a value for the magnetic declination is input to the sensor (see Appendix A). It is not necessary to manually align the TACMET II, TRV, Upgrade Weather Station towards North. 4.0 Input/Output Connections The sensors' pin designations are as follows: PIN FUNCTION A Power and RS232 Ground B +9 to +36 Vdc Power Input C N/C D N/C E N/C F N/C G RS232 Receive Data H RS232 Transmit Data I N/C J N/C Radio Antenna Connector: TNC Jack 102902-9800 Operation Manual ISO 9001:2015 Certified 9 Revision B, 10/3/2024 5.0 User Interface The internal serial port works in parallel with the radio. The unit is set for polled operation. The output of the TACMET II, TRV, Upgrade is a serial data stream. Typically, the output is set for 19.2k baud (N/8/1) and outputs the data string when polled. The data can be viewed, displayed, and logged using Met One AWeather Software. An example of the output format is shown below: <STX>R S0011 000.6 102 +077.1 055 29.77 63<EOT> The string consists of eight fixed length fields each separated by a space (0x20) character. Each data field contains leading zeros, temperature is preceded by a plus or minus sign. Field 1: Start of transmission character <STX> immediately followed by an R Field 2: Serial number of the sensor (Snnnn) Field 3: Wind speed data in miles per hour (nnn.n) Field 4: Wind direction data in degrees (nnn) Field 5: Temperature data in degrees Fahrenheit (+/-nnn.n) Field 6: Relative humidity data in percent (nnn) Field 7: Barometric pressure data in inches of mercury (nn.nn) Field 8: Two digit Checksum two-digit checksum immediately followed by an end of transmission character (nn<EOT>). The Checksum is the Twos Complement (Negated) of the 8 bit sum of all the characters in the output including the <STX> character to start the message and the ending <EOT> character (not including the Checksum itself). The Checksum is inserted into the string before transmission. The polling string is set at the factory during manufacturing. The string is set to the sensor serial number using the terminal commands. Should it become necessary to re-set the polling string in the field, please refer to Appendix A for instructions on how to enter the terminal command mode and the "ST" command. 102902-9800 Operation Manual ISO 9001:2015 Certified 10 Revision B, 10/3/2024 6.0 Calibration A zero wind speed check can be done by covering the sensor with a thick plastic bag sealed beneath the sensor. The wind speed should read zero, and the wind direction will bounce around. WS, WD, temperature, relative humidity and pressure should be checked by co-location with a reference sensor. For formal calibration, the unit needs to be returned to the factory. The sensor requires a wind tunnel for WS/WD calibration. Met One Instruments, Inc. can provide NIST traceable calibration in our wind tunnel. Please contact the factory for details. 7.0 Maintenance Because the sensor has no moving parts to wear out, periodic maintenance is not required. In extremely corrosive environments, the condition of the connector used to mount the sensor should be checked. In harsh environments, the transducer screens should be checked for dust or sand buildup. Should the transducer screens need to be cleaned, with the unit upright, brush the transducer screens with a short, medium to firm bristle brush. There are no adjustments or user repairable parts located inside the sensor. 102902-9800 Operation Manual ISO 9001:2015 Certified 11 Revision B, 10/3/2024 Appendix A Terminal Mode Commands Connect to a computer running a terminal emulator program like Putty at 19200, N, 8, 1. Power up the TACMET II, TRV, Upgrade and hit Ctrl T within 2 seconds of powering the sensor. Terminal mode times-out after 2 minutes of inactivity. Successful entry into Terminal Mode will return the prompt: Command (HE for Help, QU to Quit): HE - Display Help Menu HE Display the Help menu Command: HE<cr> HE - This Help Menu BV - Battery Voltage Printout Toggle On/Off CV - Compass Heading Printout Toggle On/Off MD - Set Magnetic Declination OI - Set Output Interval PU - Set Pressure Units QU - Quit command mode and save any changes SA SDI Address SB - Set Baud rate SP - Sign-on Prompt Toggle On/Off ST - Set Serial Trigger Address SU - Set Speed Units TU - Set Temperature Units VN - Display Firmware Version Number SU - Wind Speed Units Read or Set output Units for Wind Speed. COMMAND SU<cr> SU0<cr> SU1<cr> SU2<cr> SU3<cr> RESULT Report Units setting M/S (Default) MPH Knots KPH TU - Temperature Units Read or Set output Units for Temperature. COMMAND TU<cr> TU0<cr> TU1<cr> RESULT Report Units setting Celsius (Default) Fahrenheit PU - Pressure Units Read or Set output Units for Pressure 102902-9800 Operation Manual ISO 9001:2015 Certified 12 Revision B, 10/3/2024 COMMAND PU<cr> PU0<cr> PU1<cr> RESULT Report Units setting hPa (Default) Inches of Mercury SB - Serial Baud Rate Read or Set Baud Rate Note: This command is not supported by Tracker Output. Tracker output is fixed at 9600 Baud. COMMAND SB<cr> SB1<cr> SB2<cr> SB3<cr> SB4<cr> SB5<cr> RESULT Report Baud Rate setting 1200 baud 2400 baud 4800 baud 9600 baud 19200 baud (Default) Baud rate changes take effect after cycling power to the sensor. BV - Toggle Battery Voltage Printout in data string Read or Set the Battery Voltage output option COMMAND BV<cr> BV0<cr> BV1<cr> RESULT Report option setting Battery Voltage printout Disabled (Default) Battery Voltage printout Enabled CV - Toggle Compass Heading Printout in data string Read or Set the Compass Heading output option COMMAND CV<cr> CV0<cr> CV1<cr> RESULT Report option setting Compass Heading printout Disabled (Default) Compass Heading printout Enabled MD - Magnetic Declination Read or Set the Magnetic Declination COMMAND MD<cr> MDXX.X<cr> RESULT Report Magnetic Declination setting Set Declination to XX.X Degrees Note: West declination values are entered and reported as negative values. 102902-9800 Operation Manual ISO 9001:2015 Certified 13 Revision B, 10/3/2024 ST - Serial Trigger Read or Set the Serial Trigger character string (Poll command). This can be any alpha numeric value, limited to six digits. The serial trigger is case sensitive. Note: ST must be immediately followed by the serial trigger string. Do not add a space between the command and trigger. COMMAND ST<cr> STXXXXXX<cr> RESULT Report Serial Trigger string setting Set Serial Trigger VN - Software Version Number Report the current Software Version Number COMMAND VN<cr> RESULT Report current Software Version OI - Output Interval Read or Set the Output Interval COMMAND OI<cr> OI1<cr> OI2<cr> OI3<cr> OI4<cr> OI5<cr> OI6<cr> RESULT Report Output Interval setting Sensor Output every 1 second (Default) Sensor Output every 2 seconds Sensor Output every 5 seconds Sensor Output every 15 seconds Sensor Output every 30 seconds Sensor Output every 60 seconds Read or Set the SDI Address COMMAND SA<cr> SAX<cr> SA SDI Address RESULT Report SDI-12 Address Set SDI-12 Address (X may be [0-9], [A-Z], or [a-z]; case sensitive) SP - Sign-On Prompt Read or Set the Sign-On Prompt output option at power-up COMMAND SP<cr> SP0<cr> SP1<cr> RESULT Report option setting Sign-On Prompt Disabled (Default) Sign-On Prompt Enabled QU - Quit Exit the command mode and query to save any changes. Command (HE for Help, QU to Quit): QU<cr> To save changes type 'Y' : N<cr> Restarting 102902-9800 Operation Manual ISO 9001:2015 Certified 14 Revision B, 10/3/2024 Appendix B Theory of Operation Winds Met One's sonic anemometer, which is part of the TACMET II, TRV, Upgrade, operates on the principal that the speed of the wind effects the time it takes for sound to travel from one point to a second point. If the sound is traveling in the direction of the wind, the transit time is decreased. If the sound is traveling in a direction opposite the wind, the transit time is increased. This principal is well known and is the basis of most sonic anemometers. Temperature / Humidity The temperature sensor in the P/N 102902 TACMET II, TRV, Upgrade uses a precision single-element thermistor. This provides a highly accurate and stable temperature reading. The resistance value is 10K ohms at 25°C. This allows the TACMET II to directly interface with the temperature sensor without additional electronics; sensor compensation is handled through software. The relative humidity sensor is a capacitive element sensor. It has a linear voltage output connected directly to the TACMET II, TRV, Upgrade microprocessor. The humidity sensor element's construction provides excellent resistance to wetting, dust, dirt, oils, and common environmental chemicals. A heavy contaminant layer of dirt will slow down the sensor's response time because it will take longer for water vapor to equilibrate in the sensor. Barometric Pressure The P/N 102555 barometer uses proven silicon sensor technology with microprocessor-based signal compensation, eliminating the need to insulate or temperature-regulate the barometer. The P/N 102555 has a pressure range of 14.75 to 35.50 in Hg (500 to 1200 hPa). The P/N 102555 has a TTL output that reduces the power consumption of the barometer to 33 mW. The accuracy of the sensor is ±0.4 hPa (0.01 in Hg) 102902-9800 Operation Manual ISO 9001:2015 Certified 15 Revision B, 10/3/2024