User Guide for Edge-core models including: AIS800-64O, AIS800-64O 64-Port 800G Ethernet Switch, 64-Port 800G Ethernet Switch, 800G Ethernet Switch, Ethernet Switch, Switch
Datasheet – Edgecore Networks
AIS800-64O QSG-R01 – Edgecore Networks
Quick Start Guide 64-Port 800G Ethernet Switch AIS800-64O Package Contents www.edge-core.com 1 1. 64-Port 800G Ethernet Switch AIS800-64O 2. Slide-rail mounting kit--2 rack slide-rails and install guide 2 3 4 3. Power cord (type IEC C20/IEC C19) 4. Documentation--Quick Start Guide (this document) and Safety and Regulatory Information Overview 1 2 6 7 3 1. 64 x 800G OSFP800 ports 2. Management Ports: 1 x 1000BASE-T RJ-45, 2 x 25G SFP28, RJ-45 console, USB 3. Timing Ports: 1PPS, 10 MHz, TOD 4. System LEDs 4 5 5. 2 x grounding screws 6. 2 x AC PSUs 7. 4 x fan trays 1 2 3 5 System LEDs/Buttons 1. OSFP800 LEDs: Purple (800G), Blue (400G), Cyan (200G), Green (100G), Red (50G) 2. RJ-45 MGMT LEDs: Left: Green (link/act), Right: Green (speed) 2 3. SFP28 LEDs: Green (link/activity) 4. System LEDs: LOC: Flashing Green (switch locator) 4 DIAG: Green (OK), Red (fault) ALRM: Red (fault) FAN: Green (OK), Red (fault) PSU1/PSU2: Green (OK), Red (fault) 5. RST: Reset button FRU Replacement PSU Replacement 1. Remove the power cord. 2. Press the release latch and remove the PSU. 3. Install replacement PSU with matching airflow direction. Fan Tray Replacement 1. Pull the handle release latch. 2. Remove the fan tray from the chassis. 3. Install a replacement fan with matching airflow direction. 1 Caution: During switch operation, fan replacement should be completed within two minutes to prevent the switch shutting down due to its built-in over-temperature protection. Attention: Pendant le fonctionnement du commutateur, le remplacement du ventilateur doit être effectué dans les deux minutes pour éviter que le commutateur ne s'arrête en raison de sa protection intégrée contre la surchauffe. E032024-CS-R01 150200002691A Installation Quick Start Guide Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty. Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil. L'utilisation d'autres accessoires et vis pourrait endommager l'appareil. Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie. Note: The device has the Open Network Install Environment (ONIE) software installer preloaded, but no device software image. Note: The drawings in this document are for illustration only and may not match your particular model. 1 Mount the Device Caution: This device must be installed in a telecommunications room or a server room where only qualified personnel have access. Attention: Cet appareil doit être installé dans une salle de télécommunications ou une salle de serveurs où seul le personnel qualifié a accès. 3 Connect Power Install one or two AC PSUs and connect them to an AC power source. Note: When using only one AC PSU to power a fully loaded system, be sure to use a high-voltage source (200240 VAC). 4 Make Network Connections Using the Slide-Rail Kit Follow instructions in the install guide provided in the slide-rail kit to mount the device in a rack. 2 Ground the Device 800G OSFP800 Ports Install transceivers and then connect fiber optic cabling to the transceiver ports. Alternatively, connect DAC or AOC cables directly to the slots. 5 Connect Timing Ports Verify Rack Ground Ensure the rack on which the device is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). Attach Grounding Wire Attach a grounding wire (#6 AWG/13.3 mm2, green with yellow stripe) (not included) to the grounding point on the device rear panel (maximum torque 10 kgf-cm (8.7 lb-in)). Then connect the other end of the wire to rack ground. 1PPS Port Use a coax cable to connect the 1-pulse-per-second (1PPS) port to another synchronized device. 10 MHz Port Use a coax cable to connect the 10 MHz port to another synchronized device. TOD Port Use a shielded cable to connect the Time-of-Day (TOD) RJ-45 port to other devices that use these synchronization signals. 2 Quick Start Guide 6 Make Management Connections 25G SFP28 In-Band Management Ports Install transceivers and then connect fiber optic cabling to the transceiver ports. 10/100/1000M RJ-45 Out-of-Band Management Port Connect Cat. 5e or better twisted-pair cable. RJ-45 Console Port Use an RJ-45-to-DB-9 null-modem console cable (not included) to connect to a PC running terminal emulator software. Use a USB-tomale DB-9 adapter cable (not included) for connections to PCs that do not have a DB-9 serial port. Configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control. Console cable pinouts and wiring: Device's RJ-45 Console Null Modem PC's 9-Pin DTE Port 6 RXD (receive data) <--------------- 3 TXD (transmit data) 3 TXD (transmit data) ---------------> 2 RXD (receive data) 4,5 SGND (signal ground) ----------------- 5 SGND (signal ground) Hardware Specifications Switch Chassis Size (WxDxH) 440 x 649.2 x 87 mm (17.32 x 25.56 x 3.43 in.) Weight 20.2 kg (44.53 lb), with 2 PSUs and 4 fans installed Temperature Operating: 0° C to 40° C (32° F to 104° F) Storage: -40° C to 70° C (-40° F to 158° F) Humidity Operating: 5% to 95% (non-condensing) AC PSU AC Input 200-240 VAC, 50/60 Hz, 16 A max. System Input Rating AC Input 200-240 VAC, 50/60Hz, 16 A max. per PS Regulatory Compliances Emissions EN 55032 Class A EN 61000-3-2 EN 61000-3-3 VCCI-CISPR 32 Class A AS/NZS CISPR 32 Class A ICES-003 Issue 7 Class A FCC Class A EN 300 386 Class A Immunity EN 55035 IEC 61000-4-2/3/4/5/6/8/11 EN 300 386 Safety UL (CSA 22.2 No 62368-1 & UL62368-1) CB (IEC/EN 62368-1) 3 Adobe PDF Library 17.0