Product Usage Instructions

  • Setup and Installation
    • Follow these steps to set up your SALICRU SPS HOME+ uninterruptible power supply:
    • Identify a suitable location with proper ventilation and away from direct sunlight.
    • Connect your PC, monitor, and other sensitive equipment to the SPS HOME+ outlets.
    • Ensure all connections are secure and avoid direct contact with live components.
  • Powering On and Off
    • To power on the SPS HOME+, press the power button. To power off, press and hold the same button.
  • Charging USB Devices
    • If you have the 850 VA or 1000 VA model with a USB charging port, you can connect your devices for charging.
    • The USB port provides a total output of 5V/2.4A, suitable for charging smartphones and tablets.
  • LED Indicators
    • The LED indicators on the SPS HOME+ display different statuses such as overload, battery level, and system alerts.

FAQs

  • Q: What should I do if the LED indicators show an overload?
    • A: In case of an overload, disconnect some devices from the SPS HOME+ to reduce the load and prevent damage.
  • Q: Can I use the USB charging port while the SPS HOME+ is in standby mode?
    • A: Yes, you can still charge your devices using the USB port even when the SPS HOME+ is in standby mode.

“`

INTRODUCTION

1.1. THANK YOU LETTER.
We thank you in advance for the trust placed in us in the purchasing of this product. Read this instruction manual carefully in order to familiarise yourself with its content, since the more you know and understand the device the greater your satisfaction, level of safety and optimisation of its functionalities will be. We remain at your disposal for any additional information or queries that you may wish to make.
Yours sincerely.
SALICRU
The equipment described here is capable of causing significant physical damage in the event of incorrect connection and/ or operation. For this reason, its installation, maintenance and/or repair must be carried out exclusively by our staff or by qualified personnel. · Although no effort has been spared to ensure that the informa-
tion in this user manual is complete and accurate, we accept no liability for any errors or omissions that may exist. The images included in this document are for illustrative purposes and may not exactly represent the parts of the device shown; therefore they are not contractual. However, any divergence that may arise will be remedied or solved with the correct labelling on the unit. · Following our policy of constant evolution, we reserve the right to modify the characteristics, operations or actions described in this document without prior notice. · Reproduction, copying, assignment to third parties, modification or total or partial translation of this manual or document, in any form or by any means, without previous written permission by us is prohibited, with the company reserving full and exclusive property rights over it.

22

SALICRU

SAFETY INFORMATION

2.1. USING THIS MANUAL.
The documentation for any standard device is available to the customer for download on our website:
(www.salicru.com).
· For devices “powered by socket” this is the website for obtaining the user manual and “Safety Instructions” EK266*08.
· For devices with “permanent connection” via terminals, a CD-ROM or pen drive containing all necessary information for connection and startup, including “Safety Instructions” EK266*08, may be supplied with it.
Before carrying out any action on the device relating to its installation or startup, change of location, configuration or handling of any kind, carefully read the safety instructions.
The purpose of the user manual is to provide information regarding safety and explanations of the procedures for installation and operation of the equipment. Read them carefully and follow the steps indicated in the order established.
Compliance with the “Safety Instructions” is obligatory, with the user being legally responsible for observing and applying them.
The device is delivered properly labelled for correct identification of each of its parts, which, together with the instructions described in this user manual, allows installation and start-up operations to be performed in a simple and organised manner without any doubts whatsoever.
Finally, once the equipment is installed and operating, it is recommended to save the documentation downloaded from the website, CD-ROM or pen drive in a safe and easy-to-access place, for any future queries or doubts that may arise.
The following terms are used interchangeably in the document to refer to:
· “SPS HOME+, SPS, HOME+, device, unit or UPS” – Uninterruptible power supply. Depending on the context of the phrase, it can refer either to the actual UPS itself or to the UPS and the batteries, regardless of whether it is all contained in the same enclosure.
· “Battery or accumulator” – Element that stores the flow of electrons by electrochemical means.
· “T.S.S.” – Technical Service and Support.
· “Customer”, “installer”, “operator” or “user” – These are used interchangeably and by extension to refer to the installer and/or operator who will carry out the corresponding actions, and the same person may be responsible for carrying out the respective actions when acting on behalf, or in representation, of the above.
USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

23

EN

QUALITY ASSURANCE AND STANDARDS

3.1. STATEMENT BY THE MANAGEMENT.
Our goal is customer satisfaction, therefore this Management has decided to establish a Quality and Environment Policy, through the implementation of a Quality and Environmental Management System that will enable us to comply with the requirements demanded in the ISO 9001 and ISO 14001 and also by our Customers and Stakeholders.
Likewise, the management of the company is committed to the development and improvement of the Quality and Environmental Management System, through:
· Communication to the entire company of the importance of satisfying both the customer’s requirements as well as legal and regulatory requirements.
· The dissemination of the Quality and Environment Policy and the setting of the Quality and Environment objectives.
· Conducting reviews by the Management.
· Providing the necessary resources.
3.2. STANDARDS.
The SPS HOME+ product is designed, manufactured and marketed in accordance with EN ISO 9001 Quality Assurance. The
marking indicates conformity with EC Directives through the application of the following standards:
· 2014/35/EU. – Low-voltage safety.
· 2014/30/EU. – Electromagnetic Compatibility (EMC).
· 2011/65/EU. – Restriction of the use of hazardous substances in electrical and electronic equipment (RoHS).
In accordance with the specifications of the harmonised standards. Reference standards:
· EN-IEC 62040-1. Uninterruptible power supplies (UPS). Part 1-1: General and safety requirements for UPS used in user access areas.
· EN-IEC 62040-2. Uninterruptible power supplies (UPS). Part 2: EMC requirements.
The manufacturer is not liable in the event of modification or intervention on the device by the user.
WARNING: The SPS HOME+ is a category C1 UPS. It is not appropriate to use this device with basic life support applications, where a failure of the former can render vital equipment out of service or significantly affect its safety or effectiveness. It is also not recommended in medical applications, commercial transport, nuclear installations, or other applications or loads, where a failure of the product can lead to personal or material damages.

The product”s CE declaration of conformity is available to the customer upon express request to our head office.
3.3. ENVIRONMENT.
This product has been designed to respect the environment and has been manufactured in our facilities certified in accordance with the ISO 14001 standard.
Recycling of the device at the end of its useful life: We undertake to use the services of authorised and regulatorycompliant companies to process all of the products when they are recovered at the end of their useful life (contact your distributor).
Packaging: For the recycling of the packaging there must be compliance with the legal requirements in force, in accordance with the specific regulations of the country where the device is installed.
Batteries: Batteries pose a serious hazard to health and the environment. They must be disposed of in accordance with the laws in force.

24

SALICRU

PRESENTATION

4.1. VIEWS OF THE DEVICE.

salicru-SPS-HOME-Plus-Off-Line-APFC-Multi-Socket-FIG- (1)

1

2

650 VA

4

11

6

10

9

EN

+ +

4

1 11

12

2

850 VA

6

10

8

9

3

7

1 11

12

2

1000 VA

6

10

8

9

3

Fig. 1. Common views for all models.
4.2. KEY FOR THE VIEWS.
Input circuit breaker: provides optimum protection from
power surges.
Input cable: connects the device to the electricity supply. USB COMM port: on 850/1000 VA models only, enables con-
nection and communication between the computer’s USB port and the UPS unit.
Sockets with backup power and surge protection: Guar-
antee power supply to connected devices for a limited period of time in the event of a power failure.
Master Socket (1000 VA model): when this function is activated (using the mute button), the sockets operate as Slave
sockets, activating or deactivating depending on the status of the load connected to the Master socket. If the Master-Slave function is unavailable (650/850 VA models) or disabled (1000 VA model), the socket is still protected from surges and by the battery.

4

5

Surge-protected sockets: provide surge protection for loads
that do not require backup power.
Slave Sockets (1000 VA model): provide backup power and
surge protection for the loads connected to them. If the Master function is enabled, the slave outputs will either turn off after 2 seconds or turn on immediately, depending on the status of
the load connected to the Master socket .
If the Master-Slave function is unavailable (650/850 VA models) or disabled (1000 VA model), the slave outputs are still protected from surges and by the battery.
USB charger port (850/1000 VA models): Type A and Type
C, total output 5 V/2.4 A.
Mute button: briefly press this button twice within 3 seconds
to activate or deactivate the mute function (Default: mute off). The Master-Slave function can be configured using the mute button. For more detailed information, see chapter “5.5. Master/Slave function”.

USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

25

On/off button: press and hold for 2 seconds to switch the UPS
on or off.
11 UPS status LEDs: the green, yellow and red LEDs show the
status of the UPS.
12 Battery status LEDs: the red and green LEDs show the bat-
tery capacity status.
4.3. NOMENCLATURE.

salicru-SPS-HOME-Plus-Off-Line-APFC-Multi-Socket-FIG- (2)
SPS 850 HOME+
HOME+ Series. Power (VA). Product acronym – Standby Power Supply.
4.4. DESCRIPTION.
The SPS.HOME+ UPS series is a line-interactive series that features an electronic stabiliser (AVR Boost&Buck) designed to be fully adaptable to single-user environments.
With the attractive appearance of a power distribution unit, it features eight output power sockets, six derived from an efficient UPS capable of providing varying degrees of backup depending on the connected load level at output and two auxiliary for the most commonly used peripherals (modems, telephone lines, etc.). All of the sockets are supplied with power surge protection.
The 1000 VA model has a Master-Slave function, which activates
or deactivates the slave sockets depending on the status of the load connected to the master socket .
The main function of the UPS is to provide power, in the event of mains failure, to the devices connected to the output sockets through its internal battery for a limited time.
Line-interactive UPS systems stabilise the power line through a Boost&Buck AVR and cover mains failures by supplying a similar voltage for a limited period of time.
Under normal conditions, the UPS output is the same as the AC mains input but with stabilised voltage. By means of a real-time detection circuit, mains power outages can be quickly detected and the system switched to battery mode in less than 6 ms, ensuring that its loads remain powered with a modified sine wave.
The device”s communication and control functionalities are available through a USB port and monitoring and management software (850/1000 VA models only).

salicru-SPS-HOME-Plus-Off-Line-APFC-Multi-Socket-FIG- (3)

Input AC N
F

Input

Electronic stabiliser

Bypass

Output

filter

(buck-boost)

to relay

AC

N F

Charger

Batteries

Fig. 2. Structural block diagram.

Inverter

4.4.1. Main features.
· Line Interactive technology with AVR.
· Compatibility with APFC type loads. The vast majority of power supplies for electronic equipment are switched-mode power supplies (SMPS) and, increasingly, incorporate an active power factor correction (APFC) to minimise the distortion caused to the power line. SPS HOME+ UPSs are compatible with all equipment incorporating these features.
· Software for Windows, Linux or Mac, downloadable.
· Auto-detection of input frequency 50 / 60 Hz.
· Cold Start function.
· Automatic restart after mains failure and end of back-up time.
· UPS status LEDs.
· Overload protection by means of accessible thermal.
· Battery protection by internal fuse.
· Wall mounting brackets for wall mounting.
· Non-slip rubber feet.
· Mute button.
· Only in 850/1000VA models:
Master-Slave function (1000 VA model only). USB for monitoring software. USB interface with HID protocol. USB charger port: Type A and Type C (5V / 2.4A). Battery status LEDs..

26

SALICRU

EN

4.4.2. Status indication and alarms.

salicru-SPS-HOME-Plus-Off-Line-APFC-Multi-Socket-FIG- (4)

Normal Battery discharging
Battery low
Overload Fault

Status of the UPS

LED illuminated

Off

Alarm

LED flashes every 10 sec.

Alarm sounds every 10 sec.

LED flashes once per Alarm sounds once per

second

second.

LED flashes every 1/2 sec.

Alarm sounds every 0.5 sec.

LED illuminated

Continuous alarm

Fig. 3. Status of the device according to the status of the LEDs and the audible alarm.

25% load 50% load 75% load 100% load

Battery status

Fig. 4. Battery charge level (850 VA /1000 VA devices only).

USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

27

INSTALLATION AND OPERATION

·

Read and respect the Safety Information, described in

Chapter 2 of this document. Failure to obey some of the

instructions described in this manual can result in a serious or

very serious accident to persons in direct contact or in the vi-

cinity, as well as failures in the device and/or loads connected

to it.

·

During discharge, the equipment operates in IG (iso-

lated ground) neutral mode. This means the neutral is

not directly grounded, providing an additional layer of safety

and stability in critical situations. To ensure optimal and safe

operation, follow the guidelines in the user manual and contact

your distributor if you have any questions.

5.1. RECEPTION OF THE DEVICE.

5.1.1. Reception, unpacking and contents.

· Reception.
Check that the information on the label affixed to the packaging matches that specified on the order. Remove the packing unit and check the above information against that on the nameplate of the SPS.HOME+.
If there are any discrepancies, report them, quoting the references on the delivery note.
Check that no mishaps have occurred during transportation.
· Unpacking.
The packaging consists of a cardboard surround with fourcolour printed illustrations on all sides and two moulded pieces of expanded polystyrene (EPS) to protect the SPS. HOME+.
· Contents.

salicru-SPS-HOME-Plus-Off-Line-APFC-Multi-Socket-FIG- (5)

1

2

Item Description 1 SPS HOME+ 2 USB cable (*) 3 Detachable handle 4 Quick guide 5 Warranty slip
(*) Only for the 850/1000 VA devices.

Quantity 1 1 1 1 1

Tab. 1. List of contents.

· After reception, it is advisable to store the device in its original packaging as a preventative measure if installation is not to be carried out immediately.
· When the packaging needs to be disposed of, it must be carried out in accordance with current laws.
We advise keeping it for at least 1 year.

5.2. SITING AND CONSIDERATIONS.

5.2.1. Siting.
· Install the unit in a location which takes into consideration and complies with the Safety Instructions of document EK266*08.
· The UPS can be placed on a flat surface (on a table) or mounted on a wall using the slots on the base of the device.

3

4

5

Fig. 5. Items inside the packaging. 28

Fig. 6. Wall mounting example. For wall mounting, use “countersunk” screws (rather than the flat-headed type) with the right metrics and dimensions
to fit the hole on the SPS HOME+: · Metric: M4 · Diameter of the head: 8 mm. · Depth of the head: 2.3 mm. These dimensions will ensure the screw is perfectly recessed and aligned with the mounting surface.
SALICRU

EN

5.2.2. Considerations.
5.2.2.1. Battery charging.
· Although the unit”s internal battery is charged at the factory, it may run down during transportation and/or storage, so it should be charged for a minimum of 8 hours to ensure a full charge before using.
Although the device can operate correctly without charging the battery for the specified time, the risk of a prolonged mains outage during the first hours of operation and the UPS”s available backup time should be assessed.
· To recharge the battery, simply leave the unit plugged into an AC socket. The battery will charge irrespective of whether the SPS.HOME+ is switched on or off.
5.2.2.2. Power connected to the SPS.HOME+.
· Check that the loads connected to the power sockets do not exceed the power rating of the unit (see Section 7 of this document).
If the rated capacities are exceeded, an overload condition will occur. If mains power is present, the input breaker will trip, a long beep will sound, and, in battery mode, the device”s inverter will be blocked. Either way, the end result will be an unwanted stoppage of the device and loads. To remedy the situation, disconnect one of the loads, wait 10 seconds, check
the breaker and restart the unit using the on/off button .
· For optimum performance, keep the SPS connected to the AC mains and the load connected to the equipment below 80% of the nominal capacity.
· If the UPS is stored or put away for a prolonged period of time, protect it from dust, knocks, etc., and keep the battery fully charged. Recharge the battery according to the time set in Table 2 of the EK266*08 Safety Instructions document and in correlation with the ambient temperature to which the SPS. HOME+ is subject. That way, a longer battery life will be ensured.

5.3. CONNECTION AND COMMISSIONING.

·

All of the device”s connections, including those related

to control, will be made with all of the switches in

standby and without mains power present (UPS power supply

line selector set to “Off”).

·

It should never be forgotten that a UPS is a generator of

electrical energy, so the user must take the necessary

precautions against direct or indirect contact when it is part of

the facility.

5.3.1. Procedure to follow.
Observe the following order of operation and instructions:
1. Connect the PC, the display and the sensitive equipment to the
output sockets on the 650 VA unit and to the sockets , and on the 850/1000 VA units. Connect the modem or
other non-sensitive and low-power peripherals to the output
sockets of the SPS HOME+.
Do not plug in laser printers, paper shredders or other high-consumption electrical devices or high current probes. The power demand of any of these devices will overload the SPS and possibly damage the unit.
2. Take the power cable and connect the plug at the end to a properly connected, earthed AC socket (mains socket).
The socket that supplies power to the device must have a properly connected earth cable ( ).
The SPS.HOME+”s power socket will be protected by a fuse or circuit breaker limiter. This line must not power machines with large electrical demands such as air conditioning units, refrigerators, etc.). Avoid the use of extension cables, since the SPS itself could be considered as a PDU.
3. Press start-stop button to start the unit. The green LED 11
will illuminate and the unit will emit a beep.
It is possible to start the unit without the presence of mains power (Coldstart function) by pressing on start-
stop button . This, however, is not recommended because if
a mains failure extends beyond the available backup, it will be necessary to carry out a forced stop.
In the event of a mains failure and the battery”s backup reaching its end, the device will be automatically blocked, leaving the loads unpowered.
Similarly, when mains voltage returns, the device will start automatically.
5.3.2. USB charger port (850/1000 VA models).
Enables charging of devices such as mobile phones using Type A and Type C connectors, with a total output of 5 V /2.4 A.
5.3.3. Communications connection. USB COMM port (850/1000 VA models).
Connect the communications cable supplied with the device to the UPS”s USB port and the other end to the computer. With the Power Master software installed on the PC, both the status of the UPS can be monitored and a shutdown/automatic start can be performed remotely.

USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

29

5.3.3.1. Software.
· Free Power Master software download. Power Master is a UPS monitoring software which provides a user-friendly interface for monitoring and control. It features an auto shutdown function for systems consisting of several PCs in case of power failure. The software enables users to monitor and control any UPS in the same LAN through an USB communications port, regardless of how far away they are from each other.
· Installation procedure:
Go to the web page: http://support.salicru.com
Select the required operating system and follow the instructions described on the web page to download the software.
5.4. ASSEMBLY OF THE CABLE-ORGANISER GUIDE.
The SPS HOME+ UPS has a removable guide that functions as a cable organiser/securing device for the wiring of the various loads connected to the device.
1. Connect the various loads to the UPS sockets.

2. Fit the guide by inserting it into the slots and sliding it until it locks into place.
5.5. MASTER/SLAVE FUNCTION
In a UPS, the Master-Slave function is a special configuration in which specific connected devices are automatically controlled based on the status of another master device. In this configuration, a socket designated as the “master” controls the switching on and off of several “slave” sockets. When the device connected to the master socket switches on, the UPS detects the increase in power consumption and automatically activates the slave sockets, providing power to the devices connected to them. Similarly, when the master device is powered off, the UPS automatically cuts power to the slave sockets, reducing unnecessary power consumption and preventing the secondary devices from operating when the master device is not in use. This feature is especially useful for ensuring a more efficient and convenient power consumption management in workplace or entertainment environments where several devices depend on a single master device, such as a desktop computer and its peripherals (monitor, printer, speakers). The SPS 1000 HOME+ model is equipped with the Master-Slave
function and activates or deactivates the slave sockets de-
pending on the status of the load connected to the master socket
.
The UPS can also be configured according to the connected power. Tab. 2 describes the available settings for this function, which can
be configured using the mute button .

Master-Slave function settings

Mute button

LED display

(battery capacity: 25%, ; 50%,

; 75%,

; 100%,

)

Master-Slave settings (By default: Off)

Press and hold the mute button for 3 seconds to access the settings function. Press the mute button once to activate the Master-Slave function and change the charge level in sequence: level 0 – level 1 level 2 – level 3 – level 0.
Press and hold the mute button for 3 seconds to save the settings. If no action is registered for 1 min. the settings mode will be exited without saving the changes.

flashing – the load level is level 0: 0 W (signifies Master-Slave off)
flashing (signifies Master-Slave on, and load level 1: 40 W)
flashing (signifies Master-Slave on, and load level 2: 70 W)
flashing (signifies Master-Slave on, and load level 3: 100 W)
illuminates for 3 sec., then switches to show the battery capacity (signifies Master-Slave off).
illuminate for 3 sec., then switch to show the battery capacity (signifies Master-Slave on, and load level 1)
illuminate for 3 sec., then switch to show the battery capacity (signifies Master-Slave on, and load level 2)

illuminate for 3 sec., then switch to show the battery capacity (signifies Master-Slave on, and load level 3)

Tab. 2. Settings of the Master-Slave function on the SPS 1000 HOME+ model.

30

SALICRU

EN

MAINTENANCE, WARRANTY AND SERVICE

6.1. TROUBLESHOOTING GUIDE.

If the UPS is not working properly, before calling T.S.S., try to resolve the issue using the information in Tab. 3

Issue. UPS backup time not as expected.
UPS does not start.

Possible cause. The battery is not fully charged. Battery slightly damaged.
The “On-Off” button is designed to prevent damage when performing quick stop and run operations
SPS not connected to an AC power socket. The battery has reached the end of its service life. Mechanical problem.

Breaker tripped by an overload

The SPS”s output sockets do

not supply voltage.

Battery discharged.

Power Master inactive

Unit has been damaged by a repetition of voltage peaks. Serial port/USB cable not connected.
SPS.HOME+ does not provide battery power.

Tab. 3. Troubleshooting guide.

Solution. Connect UPS to power socket and allow to charge for at least 8 hours. Contact distributor or seller, failing that, T.S.S.
With the device on, press button to switch it off. After 10 seconds, re-press button to start the UPS again.
Connect it to a 220..240 V 50/60 Hz socket.
Contact distributor or seller, failing that, T.S.S.
If an overload is detected, an audible alarm consisting of a long beep will sound. Turn off the UPS and unplug at least one piece of connected equipment. Unplug the power cord from the UPS and reset the circuit breaker.
Connect the SPS to a power socket for at least 4 hours, preferably with no load connected to prevent a mains failure from discharging the battery and leaving the loads unpowered. Contact distributor or seller, failing that, T.S.S. Connect serial port/USB cable between SPS and computer. Use cable supplied with unit.
Switch off PC and UPS. Wait 10 seconds and restart SPS.HOME+. When restarting unit, fault should be resolved.

6.2. REPLACING AND CONNECTING THE BATTERY.
Read and follow the SAFETY INSTRUCTIONS before servicing the battery. Always do this under the supervision of personnel knowledgeable about batteries and their safety precautions.
Only use the specified type of battery. Consult your distributor to obtain replacement batteries.
Batteries pose a risk of electric shock. Do not dispose of batteries in fire, as they may explode. Follow all local requirements regarding the proper disposal of batteries.
Do not open or tamper with batteries. The electrolyte released is harmful to skin and eyes and may be toxic.
A battery can pose a high risk of short-circuit current and electric shock. Take the following precautions before replacing the battery:

· Remove all watches, rings or other metal objects. · Use only tools with insulated handles. · DO NOT place tools or other metal objects on top of the battery
or any of its terminals. · Wear rubber gloves and rubber boots.
6.2.1. Battery replacement procedure.
1. Turn the UPS upside down, remove the 3 retaining screws at the bottom and slide the battery compartment cover off the unit.

USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

31

2. Disconnect the battery cables and remove the battery from the battery compartment.

6.3. MAINTENANCE.
· The battery does not require any preventative maintenance apart from replacement.
6.4. WARRANTY CONDITIONS.

3. Install the replacement battery by connecting the red (+) cable and the black (-) cable to the same coloured connectors in the battery compartment and position the battery inside the compartment.
4. Slide back the battery compartment cover and tighten the 3 retaining screws.

6.4.1. Terms of the warranty.
On our website, you will find the warranty conditions for the product you have purchased where you can also register it. It is recommended to do so as soon as possible to include it in the database of our Technical Service and Support (T.S.S.). Among other advantages, it will streamline any regulatory procedures for the intervention of T.S.S. in the event of a fault.
6.4.2. Exclusions.
Our company will not be bound by the warranty if it notices that the defect in the product does not exist or was caused by improper use, negligence, improper installation and/or verification, attempts at unauthorised repair or modification, or any other cause beyond the intended use, or by accident, fire, lightning or other hazards. Nor shall it cover any compensation for loss or damage.
6.5. TECHNICAL SERVICES NETWORK.
Information about our national and international Technical Service and Support (T.S.S.) centres can be found on our website.

32

SALICRU

EN

ANNEXES

7.1. TECHNICAL SPECIFICATIONS.

Models Power rating Technology Format Input Rated voltage Voltage range Rated frequency Stabiliser Protection Number of power cables Output Rated voltage Voltage accuracy (battery mode) Waveform (battery mode) Frequency (battery mode) Frequency accuracy (battery mode) Transfer time Compatibility with APFC loads Overload in line mode Overload in battery mode
Output sockets
USB outputs Master/Slave function Battery Element rated voltage Number of cells / Capacity Protection Typical recharge time User-replaceable battery Visual and audible indication Indications
Audible alarm
Physical properties Dimensions (Depth x Width x Height, mm) Weight Protection rating Total output sockets Output sockets for critical loads + surge protection Output sockets with surge protection Environmental

SPS.650.HOME+ 650 VA / 360 W

SPS.850.HOME+ 850 VA / 480 W Line-interactive Multiple socket

SPS.1000.HOME+ 1000 VA / 600 W

220.. 240 V single-phase 162.. 290 V AC
50 / 60 Hz (auto-detectable) AVR (buck-boost)
10 A resettable breaker 3 (phase + neutral and earth connection) with plugs

280 W

230 V AC single-phase ± 10%
Pseudosinusoidal (simulated sinusoidal) 50 / 60 Hz ± 1 Hz
Typical 2-6 ms, Max. 10 ms 320 W

410 W

110%, output voltage cut after 1 min; > 120%, output voltage cut immediately.

8 (6 critical loads + surge protection and 2 surge protection loads) 2 USB (1 type C, 1 type A) (850 VA and 1000 VA models only)

No

5 V / 2.4 A

No

Yes (1 x Master / 3 x Slave)

12 VDC (Calcium lead-acid battery, sealed and maintenance-free)

1 / 7 Ah

1 / 9 Ah

From overcharge, deep discharge and short-circuit

8 hours

Yes.

Normal mode, battery mode, low battery, overcharge, fault
Battery mode – 1 beep every 10 seconds Low battery – 1 beep every second
Overcharge – 1 beep every 0.5 seconds Fault – 1 continuous beep

4.6 kg

335 x 185 x 122 5.2 kg IP20 8 6 2

5.8 kg

USER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

33

Operating temperature Storage temperature Acoustic noise at 1 metre Operating altitude Relative humidity Interface, communication and management USB (HID). Power Master software. Cold start. Battery self-charging. Auto start after mains failure. Standards Safety Electromagnetic Compatibility (EMC) Quality and environmental management
Tab. 4. Technical specifications.

0.. 40°C -20.. 50°C < 40 dB 3.000 m.s.m.n. 0.. 90% (non-condensing)

No

Yes.

No

Yes.

Yes.

Yes.

Yes.

EN-IEC 62040-1 EN-IEC 62040-2 ISO 9001, ISO 14001, ISO 45001

34

SALICRUUSER MANUAL

SPS HOME+ UNINTERRUPTIBLE POWER SUPPLY SYSTEMS (UPS)

35

Avda. de la Serra 100 08460 Palautordera BARCELONA Tel. +34 93 848 24 00 sst@salicru.com SALICRU.COM
Information about our technical service and support network (T.S.S.), sales network and warranty is available on our website: www.salicru.com
Product Range Uninterruptible Power Supplies (UPS) Solar Inverters Variable Frequency Drives DC Systems Transformers and Autotransformers Voltage Stabilisers Protective Power Strips Batteries

Documents / Resources

salicru SPS HOME Plus Off Line APFC Multi Socket [pdf] User Manual
SPS HOME Plus Off Line APFC Multi Socket, Off Line APFC Multi Socket, APFC Multi Socket, Multi Socket

References

Leave a comment

Your email address will not be published. Required fields are marked *