Mounting Instructions For “DL20″ Door Loops

THIS DIAGRAM APPLIES TO all DL Series Door Loops

1- Locate the centerline of the door loop on the underside of the Exit Device Housing 4″ from soffit of frame and 1″ from face of door
2- Locate the centerline of the door loop for the face of frame 2″ down from the edge of the Exit Device 3- Drill pilot holes (#24 drill) to mount the base and a 5/8″ hole for wire conduit. 4- Mount base using #10 SMS. 5- Thread electrical wires through door loop. 6- Install covers with #8 SMS screws
NOTES: Maximum electrical wires: 7 ea. 18 awg, 10 ea. 22 awg Door Loop flexible conduit can be field cut

Устройство выхода обода
4 "
DL-20 Door Loop
Door Loop Base Dimensions
625 2.013
732 200
.732
250 2.379

2 "
Alternate wall Placement. Check loop slack.