1. Введение
This manual provides essential information for the installation, operation, and maintenance of the BDCOM S2900-24T4X-2AC Ethernet Layer-3 Lite Switch. Please read this manual thoroughly before using the device to ensure proper setup and functionality. Retain this document for future reference.
2. Продукт закончилсяview
The BDCOM S2900-24T4X-2AC is a high-performance Ethernet Layer-3 Lite switch designed for various networking environments. It features 24 Gigabit Ethernet (GE) TX ports and 4 10 Gigabit Ethernet (10GE) SFP+ ports, providing flexible connectivity options. The switch also includes a console port for management and supports standard 19-inch rack-mounted installation.
2.1 Основные характеристики
- 1 Console port for device management.
- 24 Gigabit Ethernet (GE) TX ports for high-speed network connections.
- 4 10 Gigabit Ethernet (10GE/GE) SFP+ ports for uplink or high-bandwidth connections.
- AC 110V ~ 220V input, 60 Hz power supply.
- Fanless design for silent operation.
- 1U height, suitable for standard 19-inch rack-mounted installation.
2.2 Компоновка передней панели

Figure 1: Front Panel Diagram of BDCOM S2900-24T4X-2AC Switch, highlighting 24 Gigabit RJ45 ports, 4 10G/1G SFP+ ports, and the Console port.
- Консольный порт: RJ45 port for command-line interface (CLI) access.
- GE TX Ports (1-24): 24 Gigabit Ethernet ports for connecting network devices.
- 10GE/GE SFP+ Ports (TE1-TE4): 4 SFP+ slots supporting 10 Gigabit or 1 Gigabit fiber optic transceivers.
- Светодиодные индикаторы: System (SYS), Power (PWR), and individual port status indicators.

Рисунок 2: Подробный вид спереди view of the BDCOM S2900-24T4X-2AC switch, showing the arrangement of ports and indicators.
2.3 Расположение задней панели

Рисунок 3: Сзади view of the BDCOM S2900-24T4X-2AC switch, displaying the AC power input and power switch.
- Вход питания переменного тока: Connector for the AC power cord (100-240 VAC, 50/60 Hz).
- Выключатель: Кнопка включения/выключения устройства.
3. Установка
Follow these steps for proper installation of your BDCOM S2900-24T4X-2AC switch.
3.1 Подготовка места
- Убедитесь, что место установки чистое, сухое и хорошо проветриваемое.
- Поддерживайте температуру окружающей среды в пределах от 0°C до 50°C (от 32°F до 122°F).
- Avoid direct sunlight, heat sources, and excessive dust.
- Ensure adequate space around the switch for proper airflow, especially at the sides where ventilation is located.
3.2 Монтаж в стойку
The switch is designed for standard 19-inch rack-mounted installation (1U height).
- Прикрепите прилагаемые кронштейны для монтажа в стойку к боковым сторонам коммутатора с помощью винтов, входящих в комплект.
- Совместите коммутатор с стойками стойки и закрепите его с помощью соответствующих винтов для крепления к стойке.
- Ensure the switch is level and securely fastened in the rack.
3.3 Подключение питания
- Убедитесь, что выключатель питания на задней панели находится в положении ВЫКЛ.
- Connect one end of the AC power cord to the power input on the rear panel of the switch.
- Connect the other end of the AC power cord to a grounded power outlet (100-240 VAC, 50/60 Hz).
- Flip the power switch to the ON position. The Power (PWR) LED on the front panel should illuminate.
3.4 Сетевые подключения
- GE TX Ports: Connect standard RJ45 Ethernet cables from your network devices (servers, workstations, other switches) to the GE TX ports (1-24).
- 10GE/GE SFP+ Ports: Insert compatible SFP+ transceivers into the SFP+ slots (TE1-TE4). Connect fiber optic cables from other network devices or uplinks to these transceivers. Ensure the transceivers and cables match the required speed (1G or 10G).
- Консольный порт: For initial configuration and management, connect a console cable (RJ45 to DB9 or USB) from your management workstation to the console port.
4. Первоначальная настройка
The BDCOM S2900-24T4X-2AC switch can be configured via its Command Line Interface (CLI) through the console port or via a webГрафический пользовательский интерфейс (GUI) на основе графического интерфейса пользователя.
4.1 Console Access (CLI)
- Connect your computer to the switch's console port using a console cable.
- Open a terminal emulation program (e.g., PuTTY, Tera Term) on your computer.
- Configure the serial port settings:
- Скорость передачи данных: 9600
- Биты данных: 8
- Паритет: Нет
- Стоп-биты: 1
- Управление потоком: нет
- Power on the switch. The boot-up messages will appear in the terminal window.
- Log in using the default credentials (refer to the official BDCOM documentation for default username and password).
- Begin configuring the switch according to your network requirements. The command structure is similar to Cisco IOS.
4.2 Web-based Management (GUI)
Once the switch has an IP address configured (either manually via CLI or via DHCP), you can access its web интерфейс.
- Ensure your management computer is on the same network segment as the switch.
- Откройте web Введите IP-адрес коммутатора в браузере.
- Войдите в систему, используя соответствующие учетные данные.
- The GUI provides a user-friendly interface for configuring various switch functions. Note that the included PKI certificate may be expired, requiring generation of a new one for secure access.
For detailed command references and advanced configuration, please consult the official BDCOM S2900 series documentation.
5. Инструкция по эксплуатации
The BDCOM S2900-24T4X-2AC switch operates automatically once configured. Here are general operational guidelines:
- Включение/выключение питания: Use the power switch on the rear panel. Always ensure proper shutdown procedures if available through CLI/GUI before powering off.
- Светодиодные индикаторы: Следите за светодиодами на передней панели для определения рабочего состояния:
- PWR (Мощность): Зеленый цвет загорается постоянно, указывая на то, что переключатель включен.
- SYS (Система): Indicates system status (e.g., solid green for normal operation, blinking for activity or errors). Refer to the full manual for specific patterns.
- Индикаторы портов: Indicate link status and activity for each GE and SFP+ port.
- Сетевое подключение: Ensure all connected devices are properly cabled and configured for network access.
- Layer-3 Lite Functionality: The switch supports basic Layer-3 routing capabilities. Configure VLANs, IP interfaces, and static routes as needed for inter-VLAN routing and network segmentation.
- Агрегация каналов (LACP): For increased bandwidth and redundancy, configure Link Aggregation Control Protocol (LACP) on multiple ports to form a single logical link (port channel). Ensure a lower value for the 'agg-period' parameter if configuring LACP.
6. Техническое обслуживание
Регулярное техническое обслуживание поможет обеспечить долговечность и оптимальную производительность вашего коммутатора.
- Уборка: Периодически протирайте внешнюю поверхность выключателя мягкой сухой тканью. Не используйте жидкие или аэрозольные чистящие средства. Убедитесь, что вентиляционные отверстия свободны от пыли и препятствий.
- Обновления прошивки: Check the BDCOM official website for the latest firmware updates. Applying updates can improve performance, add features, and fix bugs. Follow the provided instructions carefully during firmware upgrades.
- Резервное копирование конфигурации: Regularly back up your switch configuration to an external storage device. This allows for quick restoration in case of a device reset or failure.
- Мониторинг окружающей среды: Убедитесь, что рабочая среда находится в указанном диапазоне температуры и влажности.
7. Поиск Неисправностей
В этом разделе представлены решения распространенных проблем. Для решения более сложных проблем обратитесь в службу технической поддержки.
7.1 Проблемы с питанием
- Нет питания:
- Убедитесь, что шнур питания надежно подключен как к выключателю, так и к розетке.
- Убедитесь, что выключатель питания на задней панели находится в положении «ВКЛ».
- Проверьте работоспособность розетки с помощью другого устройства.
7.2 Проблемы с сетевым подключением
- Нет связи на порту:
- Check the Ethernet or fiber cable connection. Ensure it is securely plugged into both the switch port and the connected device.
- Verify the cable is not damaged. Try a different cable.
- Убедитесь, что подключенное устройство включено и работает правильно.
- Check the port status LEDs on the switch. If the LED is off, there might be no link.
- For SFP+ ports, ensure the transceiver is correctly seated and compatible. The switch can be particular about transceivers.
- Низкая производительность сети:
- Проверьте наличие перегрузки сети.
- Verify duplex and speed settings on the switch port and connected device.
- Ensure cables are appropriate for the speed (e.g., Cat5e/6 for Gigabit Ethernet).
7.3 Management Access Issues
- Cannot Access CLI via Console:
- Verify the console cable connection.
- Check the serial port settings in your terminal emulation program (Baud Rate, Data Bits, Parity, Stop Bits, Flow Control).
- Убедитесь, что выбран правильный COM-порт.
- Cannot Access GUI via Web Браузер:
- Verify the switch has an IP address and your computer can reach it (ping the IP address).
- Убедитесь, что ваш web browser is not blocking the connection due to certificate warnings (the default certificate may be expired).
- Очистите кэш браузера или попробуйте другой браузер.
8. Технические характеристики
| Особенность | Описание |
|---|---|
| Модель | S2900-24T4X-2AC |
| Порты | 24 x GE TX ports, 4 x 10GE/GE SFP+ ports, 1 x Console port |
| Тип интерфейса | SFP, RJ45 |
| Входная мощность | 100-240 В переменного тока, 50/60 Гц |
| Безвентиляторный дизайн | Да |
| Стойка | 1U |
| Установка | Standard 19-inch rack-mounted |
| Размеры (ДxШxВ) | 19.69 x 12.6 x 3.15 дюйма (50 x 32 x 8 см) |
| Вес товара | 8.6 фунта (3.9 кг) |
| Материал корпуса | Металл |
| Рабочая температура | До 50°C (122°F) |
9. Информация по технике безопасности
Для предотвращения травм и повреждения устройства соблюдайте следующие меры предосторожности:
- Always connect the power cord to a grounded electrical outlet.
- Не эксплуатируйте устройство во влажных или сухих условиях.amp условия.
- Обеспечьте надлежащую вентиляцию, чтобы предотвратить перегрев.
- Не открывайте устройство casinг. По всем вопросам обслуживания обращайтесь к квалифицированному персоналу.
- Не кладите тяжелые предметы на переключатель.
- Перед чисткой или перемещением устройства отключите его от сети.
10. Гарантия и поддержка
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official BDCOM webсайт. Вы также можете обратиться за помощью к своему дилеру.
BDCOM Official Webсайт: www.bdcom.com.cn