BDCOM S2900-24T4X-2AC

Руководство пользователя коммутатора Ethernet Layer-3 Lite BDCOM S2900-24T4X-2AC

Model: S2900-24T4X-2AC

1. Введение

This manual provides essential information for the installation, operation, and maintenance of the BDCOM S2900-24T4X-2AC Ethernet Layer-3 Lite Switch. Please read this manual thoroughly before using the device to ensure proper setup and functionality. Retain this document for future reference.

2. Продукт закончилсяview

The BDCOM S2900-24T4X-2AC is a high-performance Ethernet Layer-3 Lite switch designed for various networking environments. It features 24 Gigabit Ethernet (GE) TX ports and 4 10 Gigabit Ethernet (10GE) SFP+ ports, providing flexible connectivity options. The switch also includes a console port for management and supports standard 19-inch rack-mounted installation.

2.1 Основные характеристики

  • 1 Console port for device management.
  • 24 Gigabit Ethernet (GE) TX ports for high-speed network connections.
  • 4 10 Gigabit Ethernet (10GE/GE) SFP+ ports for uplink or high-bandwidth connections.
  • AC 110V ~ 220V input, 60 Hz power supply.
  • Fanless design for silent operation.
  • 1U height, suitable for standard 19-inch rack-mounted installation.

2.2 Компоновка передней панели

BDCOM S2900-24T4X-2AC Front Panel Diagram

Figure 1: Front Panel Diagram of BDCOM S2900-24T4X-2AC Switch, highlighting 24 Gigabit RJ45 ports, 4 10G/1G SFP+ ports, and the Console port.

  • Консольный порт: RJ45 port for command-line interface (CLI) access.
  • GE TX Ports (1-24): 24 Gigabit Ethernet ports for connecting network devices.
  • 10GE/GE SFP+ Ports (TE1-TE4): 4 SFP+ slots supporting 10 Gigabit or 1 Gigabit fiber optic transceivers.
  • Светодиодные индикаторы: System (SYS), Power (PWR), and individual port status indicators.
BDCOM S2900-24T4X-2AC Front View

Рисунок 2: Подробный вид спереди view of the BDCOM S2900-24T4X-2AC switch, showing the arrangement of ports and indicators.

2.3 Расположение задней панели

BDCOM S2900-24T4X-2AC Rear View

Рисунок 3: Сзади view of the BDCOM S2900-24T4X-2AC switch, displaying the AC power input and power switch.

  • Вход питания переменного тока: Connector for the AC power cord (100-240 VAC, 50/60 Hz).
  • Выключатель: Кнопка включения/выключения устройства.

3. Установка

Follow these steps for proper installation of your BDCOM S2900-24T4X-2AC switch.

3.1 Подготовка места

  • Убедитесь, что место установки чистое, сухое и хорошо проветриваемое.
  • Поддерживайте температуру окружающей среды в пределах от 0°C до 50°C (от 32°F до 122°F).
  • Avoid direct sunlight, heat sources, and excessive dust.
  • Ensure adequate space around the switch for proper airflow, especially at the sides where ventilation is located.

3.2 Монтаж в стойку

The switch is designed for standard 19-inch rack-mounted installation (1U height).

  1. Прикрепите прилагаемые кронштейны для монтажа в стойку к боковым сторонам коммутатора с помощью винтов, входящих в комплект.
  2. Совместите коммутатор с стойками стойки и закрепите его с помощью соответствующих винтов для крепления к стойке.
  3. Ensure the switch is level and securely fastened in the rack.

3.3 Подключение питания

  1. Убедитесь, что выключатель питания на задней панели находится в положении ВЫКЛ.
  2. Connect one end of the AC power cord to the power input on the rear panel of the switch.
  3. Connect the other end of the AC power cord to a grounded power outlet (100-240 VAC, 50/60 Hz).
  4. Flip the power switch to the ON position. The Power (PWR) LED on the front panel should illuminate.

3.4 Сетевые подключения

  • GE TX Ports: Connect standard RJ45 Ethernet cables from your network devices (servers, workstations, other switches) to the GE TX ports (1-24).
  • 10GE/GE SFP+ Ports: Insert compatible SFP+ transceivers into the SFP+ slots (TE1-TE4). Connect fiber optic cables from other network devices or uplinks to these transceivers. Ensure the transceivers and cables match the required speed (1G or 10G).
  • Консольный порт: For initial configuration and management, connect a console cable (RJ45 to DB9 or USB) from your management workstation to the console port.

4. Первоначальная настройка

The BDCOM S2900-24T4X-2AC switch can be configured via its Command Line Interface (CLI) through the console port or via a webГрафический пользовательский интерфейс (GUI) на основе графического интерфейса пользователя.

4.1 Console Access (CLI)

  1. Connect your computer to the switch's console port using a console cable.
  2. Open a terminal emulation program (e.g., PuTTY, Tera Term) on your computer.
  3. Configure the serial port settings:
    • Скорость передачи данных: 9600
    • Биты данных: 8
    • Паритет: Нет
    • Стоп-биты: 1
    • Управление потоком: нет
  4. Power on the switch. The boot-up messages will appear in the terminal window.
  5. Log in using the default credentials (refer to the official BDCOM documentation for default username and password).
  6. Begin configuring the switch according to your network requirements. The command structure is similar to Cisco IOS.

4.2 Web-based Management (GUI)

Once the switch has an IP address configured (either manually via CLI or via DHCP), you can access its web интерфейс.

  1. Ensure your management computer is on the same network segment as the switch.
  2. Откройте web Введите IP-адрес коммутатора в браузере.
  3. Войдите в систему, используя соответствующие учетные данные.
  4. The GUI provides a user-friendly interface for configuring various switch functions. Note that the included PKI certificate may be expired, requiring generation of a new one for secure access.

For detailed command references and advanced configuration, please consult the official BDCOM S2900 series documentation.

5. Инструкция по эксплуатации

The BDCOM S2900-24T4X-2AC switch operates automatically once configured. Here are general operational guidelines:

  • Включение/выключение питания: Use the power switch on the rear panel. Always ensure proper shutdown procedures if available through CLI/GUI before powering off.
  • Светодиодные индикаторы: Следите за светодиодами на передней панели для определения рабочего состояния:
    • PWR (Мощность): Зеленый цвет загорается постоянно, указывая на то, что переключатель включен.
    • SYS (Система): Indicates system status (e.g., solid green for normal operation, blinking for activity or errors). Refer to the full manual for specific patterns.
    • Индикаторы портов: Indicate link status and activity for each GE and SFP+ port.
  • Сетевое подключение: Ensure all connected devices are properly cabled and configured for network access.
  • Layer-3 Lite Functionality: The switch supports basic Layer-3 routing capabilities. Configure VLANs, IP interfaces, and static routes as needed for inter-VLAN routing and network segmentation.
  • Агрегация каналов (LACP): For increased bandwidth and redundancy, configure Link Aggregation Control Protocol (LACP) on multiple ports to form a single logical link (port channel). Ensure a lower value for the 'agg-period' parameter if configuring LACP.

6. Техническое обслуживание

Регулярное техническое обслуживание поможет обеспечить долговечность и оптимальную производительность вашего коммутатора.

  • Уборка: Периодически протирайте внешнюю поверхность выключателя мягкой сухой тканью. Не используйте жидкие или аэрозольные чистящие средства. Убедитесь, что вентиляционные отверстия свободны от пыли и препятствий.
  • Обновления прошивки: Check the BDCOM official website for the latest firmware updates. Applying updates can improve performance, add features, and fix bugs. Follow the provided instructions carefully during firmware upgrades.
  • Резервное копирование конфигурации: Regularly back up your switch configuration to an external storage device. This allows for quick restoration in case of a device reset or failure.
  • Мониторинг окружающей среды: Убедитесь, что рабочая среда находится в указанном диапазоне температуры и влажности.

7. Поиск Неисправностей

В этом разделе представлены решения распространенных проблем. Для решения более сложных проблем обратитесь в службу технической поддержки.

7.1 Проблемы с питанием

  • Нет питания:
    • Убедитесь, что шнур питания надежно подключен как к выключателю, так и к розетке.
    • Убедитесь, что выключатель питания на задней панели находится в положении «ВКЛ».
    • Проверьте работоспособность розетки с помощью другого устройства.

7.2 Проблемы с сетевым подключением

  • Нет связи на порту:
    • Check the Ethernet or fiber cable connection. Ensure it is securely plugged into both the switch port and the connected device.
    • Verify the cable is not damaged. Try a different cable.
    • Убедитесь, что подключенное устройство включено и работает правильно.
    • Check the port status LEDs on the switch. If the LED is off, there might be no link.
    • For SFP+ ports, ensure the transceiver is correctly seated and compatible. The switch can be particular about transceivers.
  • Низкая производительность сети:
    • Проверьте наличие перегрузки сети.
    • Verify duplex and speed settings on the switch port and connected device.
    • Ensure cables are appropriate for the speed (e.g., Cat5e/6 for Gigabit Ethernet).

7.3 Management Access Issues

  • Cannot Access CLI via Console:
    • Verify the console cable connection.
    • Check the serial port settings in your terminal emulation program (Baud Rate, Data Bits, Parity, Stop Bits, Flow Control).
    • Убедитесь, что выбран правильный COM-порт.
  • Cannot Access GUI via Web Браузер:
    • Verify the switch has an IP address and your computer can reach it (ping the IP address).
    • Убедитесь, что ваш web browser is not blocking the connection due to certificate warnings (the default certificate may be expired).
    • Очистите кэш браузера или попробуйте другой браузер.

8. Технические характеристики

ОсобенностьОписание
МодельS2900-24T4X-2AC
Порты24 x GE TX ports, 4 x 10GE/GE SFP+ ports, 1 x Console port
Тип интерфейсаSFP, RJ45
Входная мощность100-240 В переменного тока, 50/60 Гц
Безвентиляторный дизайнДа
Стойка1U
УстановкаStandard 19-inch rack-mounted
Размеры (ДxШxВ)19.69 x 12.6 x 3.15 дюйма (50 x 32 x 8 см)
Вес товара8.6 фунта (3.9 кг)
Материал корпусаМеталл
Рабочая температураДо 50°C (122°F)

9. Информация по технике безопасности

Для предотвращения травм и повреждения устройства соблюдайте следующие меры предосторожности:

  • Always connect the power cord to a grounded electrical outlet.
  • Не эксплуатируйте устройство во влажных или сухих условиях.amp условия.
  • Обеспечьте надлежащую вентиляцию, чтобы предотвратить перегрев.
  • Не открывайте устройство casinг. По всем вопросам обслуживания обращайтесь к квалифицированному персоналу.
  • Не кладите тяжелые предметы на переключатель.
  • Перед чисткой или перемещением устройства отключите его от сети.

10. Гарантия и поддержка

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official BDCOM webсайт. Вы также можете обратиться за помощью к своему дилеру.

BDCOM Official Webсайт: www.bdcom.com.cn

© 2023 BDCOM. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.