AmScope B120C

AmScope B120C Series Binocular Compound Microscope User Manual

Model: B120C | Brand: AmScope

1. Продукт закончилсяview

The AmScope B120C compound binocular microscope is designed for both student and professional use, offering a wide magnification range from 40X to 2500X. It features a comfortable Siedentopf head, precise 3D mechanical stage, and bright LED illumination, making it suitable for detailed examination of various specimens.

AmScope B120C Binocular Compound Microscope with eyepieces and oil

Figure 1.1: The AmScope B120C Binocular Compound Microscope, showcasing its main components including the binocular head, objective lenses, mechanical stage, and included eyepieces and immersion oil.

  • Magnification Excellence: Offers a broad magnification range from 40X to 2500X for detailed specimen examination.
  • Advanced LED Illumination: Provides bright, daylight-balanced illumination with a specialized fly-eye lens for optimal viewинж.
  • Эргономичный дизайн: Features a 360-degree rotatable Siedentopf head with adjustable interpupillary distance for comfortable and flexible viewинж.
  • Точность Stagе Управление: A 3D mechanical stage and coaxial coarse and fine focus knobs allow for smooth and precise adjustments.

2. Что в коробке

После распаковки убедитесь в наличии всех следующих компонентов:

  • AmScope B120C microscope with double-layer mechanical stage
  • (4) DIN Standard Objectives: 4x, 10x, 40xS, and 100xS (oil)
  • 10x widefield eyepieces, one pair
  • 25x widefield eyepieces, one pair
  • Color filter, blue
  • Immersion oil, one bottle
  • Пылезащитный чехол
  • Инструкции (данное руководство)

3. Руководство по установке

Follow these steps to set up your AmScope B120C microscope:

  1. Распаковка: Осторожно извлеките все компоненты из упаковки. Сохраните оригинальную упаковку для дальнейшего хранения или транспортировки.
  2. Размещение: Установите микроскоп на устойчивой, ровной поверхности, вдали от прямых солнечных лучей, чрезмерного тепла и вибраций.
  3. Install Eyepieces: Insert the desired pair of eyepieces (10x or 25x) into the ocular tubes of the Siedentopf head.
  4. Подключите питание: Plug the power cord into the microscope's power input and then into a standard electrical outlet (100 to 240VAC 50/60Hz).
  5. Пылезащитный чехол: Keep the dust cover on the microscope when not in use to protect it from dust and debris.

Видео 3.1: Оверview of the AmScope B120C Siedentopf Binocular Compound Microscope, demonstrating its features and basic setup. This video is provided by United Scope LLC, the manufacturer.

4. Инструкция по эксплуатации

4.1. Регулировка увеличения

The microscope offers a wide range of magnification by combining different eyepieces and objective lenses. The total magnification is calculated by multiplying the eyepiece magnification by the objective lens magnification.

  • Окуляры: Use either the 10x widefield or 25x widefield eyepieces.
  • Объективные линзы: Rotate the forward-facing nosepiece to select from 4x, 10x, 40xS (spring-loaded), and 100xS (spring-loaded, oil immersion) DIN achromatic objectives.
  • The 40xS and 100xS objectives are spring-loaded to prevent damage to slides when focusing.
Close-up of AmScope B120C objective lenses and WF25X eyepieces

Figure 4.1: Detail of the objective lenses (4x, 10x, 40x, 100x) and the additional WF25X eyepieces, illustrating the microscope's magnification capabilities.

4.2. Управление освещением

The microscope uses lower (diascopic) Brightfield LED illumination to transmit light through the specimen.

  • Светодиодный источник света: Turn on the LED illumination using the power switch. Adjust the brightness using the rheostat control knob.
  • Abbe Condenser (1.25 NA): Adjust the condenser to control the distance of the light from the stage.
  • Ирисовая диафрагма: Use the iris diaphragm lever to optimize the amount of light illuminating the specimen, enhancing contrast and resolution.
AmScope B120C microscope showing LED transmitted illumination

Figure 4.2: The LED transmitted illumination system, providing bright and cool light for viewing specimens from below the stage.

4.3. Фокусировка

Achieve clear focus using the coaxial coarse and fine focus knobs:

  • Ручка грубой фокусировки: Use for large adjustments to bring the specimen into approximate focus, especially with lower magnification objectives.
  • Ручка точной фокусировки: Use for small, precise adjustments to achieve sharp focus, particularly with higher magnification objectives.
Close-up of AmScope B120C mechanical stage and focus knobs

Рисунок 4.3: Механические свойстваtage and coaxial coarse and fine focus knobs, designed for smooth and accurate specimen positioning and focusing.

4.4. Механический Сtage Эксплуатация

Двухслойная механическая сtage allows for precise movement of the slide.

  • Slide Holder: Secure the microscope slide using the slide clips on the mechanical stage.
  • X-Y Axis Control: Use the X-Y axis knobs located below the stage to move the slide horizontally and vertically, allowing you to scan the specimen area.

4.5. Siedentopf Head Adjustment

The Siedentopf binocular head is designed for comfortable viewинг и обмен.

  • Inter-pupillary Adjustment: Adjust the distance between the two ocular tubes (53 to 77mm) to match your eye spacing for comfortable viewинж.
  • Диоптрийная регулировка: Use the diopter ring on one of the ocular tubes to compensate for differences in eye strength between your left and right eyes.
  • Вращение: The head can rotate 360 degrees, which is useful for sharing the view with others without moving the entire microscope.
AmScope B120C microscope with 360 degree rotatable binocular head

Figure 4.4: The 360-degree rotatable Siedentopf binocular head, angled at 30 degrees for ergonomic viewing and easy sharing.

5. Техническое обслуживание

Надлежащий уход обеспечивает долговечность и оптимальную работу вашего микроскопа:

  • Очистка линз: Use only specialized lens cleaning paper and solution to clean objective lenses and eyepieces. Avoid touching optical surfaces with bare hands.
  • Очищающее тело: Протрите корпус микроскопа мягкой тряпкой.amp ткань. Избегайте использования агрессивных химикатов или абразивных чистящих средств.
  • Защита от пыли: Always use the provided dust cover when the microscope is not in use to prevent dust accumulation.
  • Хранилище: Store the microscope in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Иммерсионное масло: После использования 100-кратного иммерсионного объектива немедленно очистите линзу от масла с помощью салфетки для линз и чистящего раствора.

6. Поиск Неисправностей

В этом разделе рассматриваются распространенные проблемы, с которыми вы можете столкнуться:

ПроблемаВозможная причинаРешение
Нет освещенияPower cord not connected, power switch off, bulb failure, fuse blown.Check power connection. Turn on power switch. Replace LED bulb (contact support if needed). Check/replace fuse.
Изображение размыто или не в фокусеIncorrect focus adjustment, dirty lenses, objective not fully clicked into place.Adjust coarse and fine focus. Clean objective and eyepiece lenses. Rotate objective until it clicks into position.
Dark spots in the field of viewПыль на окуляре, объективе или конденсоре.Clean eyepieces and objectives. Check for dust on the condenser and stage.
Double image when using binocular headInter-pupillary distance not correctly adjusted.Adjust the inter-pupillary distance until a single circular field of view наблюдается.

7. Технические характеристики

ОсобенностьДеталь
ГоловаCompound binocular, Siedentopf, 30-degree inclination, 360-degree rotatable
ОкулярыWF 10x, WF 25x
Цели4X, 10x, 40xS, 100xS (oil) DIN achromatic
Диапазон увеличения40X-2500X
StageДвухслойная механическая Stage with 1mm divisions
ФокусКоаксиальные ручки грубой и точной фокусировки.
Конфигурация освещенияTransmitted (bottom) Brightfield
Конденсатор1.25 NA Abbe with iris diaphragm
Источник светаВЕЛ
Власть100 to 240VAC 50/60Hz
Размеры продукта18 x 12 x 10 дюйма
Вес товара3.25 фунта
МатериалEnamel-coated cast-steel body

8. Гарантия и поддержка

AmScope products are manufactured by United Scope LLC, a company founded in 1996 and headquartered in Irvine, CA. For technical support, warranty information, or service inquiries, please contact AmScope customer service directly. Refer to the official AmScope webсайт для получения самых последних контактных данных и информации о гарантийных условиях.

Интернет-ресурсы:

  • Official AmScope Webсайт: www.amscope.com
  • Product Support Page: Check the AmScope website for specific support pages related to the B120C model.

© 2024 AmScope. All rights reserved.

Ask a question about this manual