A0022583 Starrsed DL Automated True Westergren
“
Product Information
Specifications:
- Product Name: Starrsed DL
- Supplier: Mechatronics Instruments B.V.
- Intended Purpose: Reagent for automatic dilution of blood
samples in Starrsed ESR analyzers
Product Usage Instructions:
- Remove the cap from the new container using the container cap
tool A0033594. - Remove the cap with pickup tube from the empty reagent
container. - Replace the empty container with the new one.
- Place the cap with the pickup tube on the new container,
avoiding touching the pickup tube that goes into the
container.
Chemical/Physical Data:
Contains a slightly hypertonic amount of citrate.
FAQ
Q: Can I use this product with analyzers other than
Starrsed?
A: No, this product is specifically designed for use with
Starrsed analyzers only.
Q: What should I do if I accidentally touch the pickup
tube?
A: If you accidentally touch the pickup tube that goes into the
container, clean it with a suitable disinfectant before use.
Q: How should I store the reagent container?
A: Store the reagent container in a cool, dry place away from
direct sunlight and extreme temperatures.
“`
Package insert
D0071169-EN-A01 (01-04-2025)
A0022583
Starrsed DL
Supplier: Mechatronics Instruments B.V.
De Corantijn 13 1689 AN Zwaag The Netherlands T +31 229 291 129
Intended purpose Reagent for the automatic dilution of blood samples in Starrsed ESR analyzers.
Instructions For Use The product is for use on the Starrsed analyzers only. See the instrument manual for detailed instructions.
1. Remove the cap from the new container, using the container cap tool A0033594. 2. Remove the cap with pickup tube from the empty reagent container. 3. Replace the empty container with the new one. 4. Place cap with pickup tube on the new container. Avoid touching the pickup tube which goes into the container.
Chemical/Physical data Contains a slightly hypertonic amount of citrate (<3.5 % by weight) and preservative (4 by weight)
Packaging Starrsed DL is supplied in 10 Liter jerrycans, LxWxH = approx.23x19x31 cm.
Safety Any serious incident that has occurred in relation to this product must be reported to the distributor and/or manufacturer and the competent local authorities. The latest version of the Safety Data Sheet is available on the website www.rrmechatronics.com
Storage and stability Transport stability at 5 – 60 °C (maximum of 1 month) Shelf life after production: 2 years, but no longer than the expiry date. Store at 5 – 35 °C in dry conditions in well sealed containers. In-use stability: Maximum of 3 months at advised temperature of 5 – 30°C.
Ecological information Generally not hazardous for water.
Waste treatment and cleaning Avoid discharge to lakes, streams, sewers, etc. Disposal must be made according to official regulations. Wherever possible cleaning should be performed with normal cleaning agents. Avoid use of solvents.
1
RR Mechatronics Manufacturing B.V. De Corantijn 13, 1689 AN Zwaag, The Netherlands www.rrmechatronics.com rev. A01 Initial release
2
Documents / Resources
![]() | RR Mechatronics A0022583 Starrsed DL Automated True Westergren [pdf] Instructions A0022583 Starrsed DL Automated True Westergren, A0022583, Starrsed DL Automated True Westergren, Automated True Westergren, True Westergren |