Queclink offers this information as a service to its customers, to support application and engineering efforts that use the products designed by Queclink. The information provided is based upon requirements specifically provided to Queclink by the customers. Queclink has not undertaken any independent search for additional relevant information, including any information that may be in the customer’s possession. Furthermore, system validation of this product designed by Queclink within a larger electronic system remains the responsibility of the customer or the customer’s system integrator. All specifications supplied herein are subject to change.

Copyright

This document contains proprietary technical information which is the property of Queclink Wireless Solutions Co., Ltd. The copying of this document, distribution to others, and communication of the content thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of a patent grant or registration of a utility model or design. All specifications supplied herein are subject to change without notice at any time.

Introduction

QLC300NA module is a highly cost-efficient LTE Cat 1 module. The module integrates LTE CAT1 modem baseband and RF transceiver to cover 600MHz~2.7GHz bands for worldwide roaming. The application subsystem runs on a Cortex-R5 processor with integrated application processing subsystem, communication subsystem, audio codec, and embedded p SRAM + flash to enable the most compact single-chip LTE single-mode data module, POC, POS, and other IoT solutions.

Reference
Table 1: QLC300NA Document Reference
SNDocument NameRemark
[1]QLC300NA data sheetThe data sheet of QLC300NA

Product Overview

Description

The QLC300NA is an embedded IoT wireless communication module.

Description
Description

Pin Definition
The sequence and description of the pins are shown in the following figure.

Table 2: QLC300NA Pin Description

PIN NO.QLC300NA Net NameDescription
1GPIO20General purpose input/ output interface
2AUXADC IN3 General purpose analog to digital converter interface
4PCM_CLKPCM clock output
5PCM_SYNCPCM frame synchronization output
6PCM_INPCM data input
7PCM_OUTPCM data output
11I2C3_SDAI2C3 serial clock
12I2C3_SCLI2C3 serial clock
13GPIO21General purpose input/ output interface
14UART4_TXDTransmit data
16UART4_RXDReceive data
18AP _12C_3_SCLAP _12C3 serial clock
19AP _12C_3_SDAAP _12C3 serial clock
20GPIO24General purpose input/ output interface
21NETLIGHTIndicate the module’s operation status
22SPI_MISOReceive data
23SPI_MOSITransmit data
24AUXADC_IN1General purpose analog to digital converter interface
25AUXADC_IN2General purpose analog to digital converter interface
26GPIO22General purpose input/output interface
27UART3_TXTransmit data
28UART3_RXReceive data
30UART1_DTRData terminal ready (sleep mode control)
34UART1_RXDReceive data
35UART1_TXDTransmit data
36UART1_RTSRequest to send
37UART1_CTSClear to send
38UART1_DCDData carrier detection
39UART1_RIRing indication
40Cl2C2_SCL12C1 serial clock.
41Cl2C2_SDAI2C1 serial clock.
42USIM_PRESENCE(U)SIM card insertion detection
63GPIO25General purpose input/ output interface
64GPI034General purpose input/ output interface
65STATUSIndicate the module’s operation status
66GPI033General purpose input/ output interface
76GPI010General purpose input/ output interface
77GPIO11General purpose input/ output interface
78GPI0122General purpose input/ output interface
83GRFC_2General purpose input/ output interface
84GRFC_1General purpose input/ output interface
85GPI037General purpose input/ output interface
86GPIO27General purpose input/ output interface
87GPI035General purpose input/ output interface
92GPIO26General purpose input/ output interface
93AUD_MICBIASAUDIO Interface
94MIC_PAUDIO Interface
95MIC_NAUDIO Interface
97AUD_EARPAUDIO Interface
98AUD_EARNAUDIO Interface
8USB_VBUSUSB Interface
9USB_DPUSB Interface
10USB_DMUSB Interface
75FORCE_USBFORCE Download
15PWRKEYTurn on the Module
17RESETINReset the Module
29VDD_EXTProvide 1.8V power supply for external circuit
32VBAT_BBPower supply
33VBAT_BBPower supply
43USIM_VDD(U)SIM Interface
44USIM_RST(U)SIM Interface
45USIM_DATA(U)SIM Interface
46USIM_CLK(U)SIM Interface
47USIM_GND(U)SIM Interface
51CP_UART_FOMReceive data
52VBAT_RFPower supply
53VBAT_RFPower supply
56CP_UART_TXDTransmit data
57GPI054General purpose input/ output interface
60ANT_MAINAntenna Interface
88GPI053General purpose input/ output interface
99GPIO31General purpose input/ output interface
3,31,48, 50,54,55, 58,59,61, 62,  67~74 79~82 89~91, 100~102, 107, 111~114 GNDGround 
49,96, 103~106, 108~110 NO CONNECT NO CONNECT 

Getting Started

  1. Module & EVB
    The QLC300NA_EVB can be used to test the module.
  2. Power on the Module
    Connect the 12V charger to the EVB, switch the POWER to ON position and then press the power key.
    Note: The Force_USB switch should be in the position as the Figure5 shows. TRACQLC300NAUMO001
  3. Send Commands via USB Interface Connect the EVB to Type-C cable interface to send commands to the module.
    Step 1: Install the Drvinstaller_Queclinkx64 or Drvinstaller_Queclink USB driver on your PC.
    Step 2: Power on the module.
    Step 3: Connect the module to the USB interface. You will find the one COM port (Queclink Modem Device) on PC management, select it on QCOM tool.

  4. Upgrade the Firmware
    Step 1: Connect the 12V charger to the USB Cable.
    Step 2: Switch the Power to ON position and the Force_USB to low as Figure 8 shows.
    Step 3: Press the power key to turn on the module.
    Step 4: Use the Queclink_Firmware_Upgrade_Tool_MDM tool to upgrade.

OEM/Integrators Installation Manual

Important Notice to OEM integrators

  1. This module is limited to OEM installation ONLY.
  2. This module is limited to installation in mobile or fixed applications, according to Part 2.1091(b).
  3. The separate approval is required for all other operating configurations, including portable configurations with respect to Part 2.1093 and different antenna configurations
  4. For FCC Part 15.31 (h) and (k): The host manufacturer is responsible for additional testing to verify compliance as a composite system. When testing the host device for compliance with Part 15 Subpart B, the host manufacturer is required to show compliance with Part 15 Subpart B while the transmitter module(s) are installed and operating. The modules should be transmitting and the evaluation should confirm that the module’s intentional emissions are compliant (i.e. fundamental and out of band emissions). The host manufacturer must verify that there are no additional unintentional emissions other than what is permitted in Part 15 Subpart B or emissions are complaint with the transmitter(s) rule(s).
    The Grantee will provide guidance to the host manufacturer for Part 15 B requirements if needed.

Important Note
notice that any deviation(s) from the defined parameters of the antenna trace, as described by the instructions, require that the host product manufacturer must notify to Queclink that they wish to change the antenna trace design. In this case, a Class Il permissive change application is required to be filed by the USI, or the host manufacturer can take responsibility through the change in FCC ID (new application) procedure followed by a Class Il permissive change application.

End Product Labeling

When the module is installed in the host device, the FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: YQD-QLC300NA” The FCC ID can be used only when all FCC compliance requirements are met.

Antenna Installation

  1. The antenna must be installed such that 20 cm is maintained between the antenna and users,
  2. The transmitter module may not be co-located with any other transmitter or antenna.
  3. Only antennas of the same type and with equal or less gains as shown below may be used with this module. Other types of antennas and/or higher gain antennas may require additional authorization for operation.
    Antenna typeLTE bandLTEband4LTE bandsLTE band12TE band13
    Paddle AntennaGainGainGainGainGainGain
    2.56 dBi0.33dBi0.85 dBi0.33dBi1.49 dBi

In the event that these conditions cannot be met (for example certain laptop configurations or colocation with another transmitter), then the FCC authorization is no longer considered valid and
the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.

Manual Information to the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

List of applicable FCC rules

This module has been tested and found to comply with part 22, part 24, part 27 requirements for Modular Approval.
The modular transmitter is only FCC authorized for the specific rule parts (i.e., FCC transmitter rules) listed on the grant, and that the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. If the grantee markets their product as being Part 15 Subpart B compliant (when it also contains unintentional-radiator digital circuity), then the grantee shall provide a notice stating that the final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed.

This device is intended only for OEM integrators under the following conditions: (For module device use) 

  1. The antenna must be installed such that 20 cm is maintained between the antenna and users, and
  2. The transmitter module may not be co-located with any other transmitter or antenna.
    As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed.

Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

Documents / Resources

Queclink QLC300NA LTE Cat-1 Module [pdf] User Manual
QLC300NA LTE Cat-1 Module, QLC300NA, LTE Cat-1 Module, Cat-1 Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *