Answer
Dec 09, 2025 - 04:33 AM

If a circuit on the Vetus P6 Switch Panel is not working, you can troubleshoot the issue by following these steps:
1. **Check for Overload:** If the LED for that circuit is not lit, it may have experienced an overload. In this case, follow the appropriate steps based on the type of fuse:
- **Switch Panel with automatic fuses:** Turn the switch to the OFF position, resolve the overload problem, depress the protruding thermal protection button, and switch back to the ON position.
- **Switch Panel with glass fuses:** Turn the switch to the OFF position, resolve the overload problem, replace the blown glass fuse (10 Amp), and switch back to the ON position.
2. **Inspect Wiring:** Ensure that the plus (+) and minus (-) wires are securely connected to the appropriate terminals with the correct cross-sectional area:
- Plus (+) wire should be at least 4mm2.
- Minus (-) wire should be 2.5mm2.
- Check for any loose connections or damaged wires that may be causing the issue.
3. **Verify Equipment Connection:** Make sure that the equipment connected to the circuit, such as lighting or pumps, is properly wired with a sufficient cross-sectional area of at least 2.5mm2.
4. **Check for Proper Voltage:** Confirm that the onboard voltage matches the voltage stated on the switch panel (12 or 24 Volts). Using the incorrect voltage can lead to circuit malfunctions.
5. **Refer to the Manual:** If the issue persists, consult the Vetus P6 Switch Panel user manual for further troubleshooting tips or contact Vetus customer support for assistance.
By following these steps and referring to the user manual, you can effectively troubleshoot and resolve any issues with circuits on the Vetus P6 Switch Panel.