To configure the Morningstar RB-SHUNT BLOCK Snap-in ReadyShunt for your specific application, follow these steps based on the information provided in the user manual:
1. **Access Configuration:** You can configure the ReadyShunt using the host device's meter layout, similar to Morningstar's LiveView web pages. Enter the Installer's Code - 141 to access Installer Setup.
2. **Local Display Configuration:**
- Go to Setup and enter the Installer's Code to access Installer Setup.
- Navigate to Ready Blocks and choose the Block you want to program.
- Configure the ReadyShunt based on its installed position.
3. **Web Browser Configuration:**
- Connect the host device to a PC and open a Web browser.
- Enter the host device's IP address or NetBIOS name into the address bar.
- Configure the ReadyShunt settings as needed.
4. **Settings Options:**
- Program the ReadyShunt for Full-scale mV rating, Full-scale Amp rating, and Inversion of the current measurement polarity if necessary.
- Assign a branch type for each shunt: None, Load, Source, Net, or Monitor based on your application.
5. **Ensure Correct Configuration:**
- Take great care to correctly configure the ReadyShunt to match the installed shunts to avoid severe battery damage.
- Make sure to configure the ReadyShunt settings accurately to prevent any issues with your system.
By following these steps and referring to the user manual for detailed instructions, you can effectively configure the Morningstar RB-SHUNT BLOCK Snap-in ReadyShunt for your specific application needs.