To associate your VFC300 WiFi Data Logger to your WiFi access point, follow these steps as outlined in the installation guide:
1. **Charge the Data Logger:** Ensure the VFC300/350 data loggers are fully charged for at least 8 hours before installation.
2. **Condition the Probe:** Place the probe with the glycol bottle in the fridge/freezer for 2-3 hours to condition it.
3. **Perform Factory Reset:** Hold down the button on the front of the data logger for 20 seconds until you see "FArSFArS" to perform a factory reset.
4. **Use the Software:** Utilize the provided software to associate the logger to your WiFi access point.
5. **Check Signal Strength:** Ensure the signal strength is 5 or above when positioning the logger where it will be mounted.
6. **Determine Power Source:** Decide on the power source and route the power cable to the data logger.
7. **Install Wall Mounting Bracket:** Once the logger location is identified, install the wall mounting bracket after cleaning the area with alcohol.
8. **Route the Cable:** Use zip ties and cable tie mounts to route the cable to the logger without cinching them down yet.
9. **Secure Cables:** Once all cables are routed, cinch down the zip ties to secure them in place.
10. **Associate Logger to Cloud Account:** Sign into your Cloud account, click on "Set-Up Device," and follow the on-screen instructions to connect the data logger to your network.