To synchronize multiple Cell2 UR06 LED Flush Mount Kits, you need to connect the yellow wires from both controllers together for synchronization. When selecting Flash Patterns 1-12, all heads will flash simultaneously. When selecting Flash Patterns 15-26, Head 1A & 2A will flash alternatively with Head 1B & 2B. To have Head 1A & 2B alternate with 1B & 2A, you can reverse the lightheaded outlets on one of the Controllers (both kits must be in Flash Patterns 15-26).
To change the warning color modes:
1. Choose the desired warning mode to change and apply +VDC to its activation wire with a wire simultaneously to enter Setting Mode.
2. The lighthead will display short flashes in its current color mode.
3. You can select from Color 1 (Warning Mode 1 Pre-set), Color 2 (Warning Mode 2 Pre-set), and Color 1 alt. 2 (Warning Mode 3 Pre-set).
4. Remove the wire from +VDC and momentarily apply it again to change the color mode.
5. Once in the desired color mode, save and exit Setting Mode by powering off the lighthead.
To change the flash patterns:
1. While a warning mode is activated, momentarily apply +VDC to the wire:
- Once for the next pattern.
- Quickly three times to reset to FP#1 (refer to the flash pattern chart provided in the manual).
For installation:
- For flush mount, drill a 1" cut-out, install the mounting grommet, and insert the lighthead. Apply silicone if necessary to prevent rotation.
- For bracket mount, align the triangle mark on the lens vertically, secure the lighthead onto the bracket, and then secure the bracket onto the mounting surface with screws.