To adjust the ALC control switch on the PENTAIR Myers ALC Adjustable Level Sealed Sump Level Control, follow these steps:
1. **Mounting:** Ensure the switch is mounted correctly on the discharge pipe or through a flange on the pump cover as per the provided instructions. Position the weights on the support cable so that they hang freely without touching the pump or basin walls. The lower weight should be at least 4 inches off the sump bottom, and the top of the upper weight should be below the bottom of the inlet pipe.
2. **Cutting Cable:** Trim any excess cable so that it does not extend below the bottom of the lower weight. After cutting the cable, adjust the lower weight by sliding it down 1/4 inch to prevent the cable end from being exposed, which could lead to faulty switch operation.
3. **Switch Operation:** The ALC control switch operates based on the displacement weights' position on the cable. When the water level rises in the sump, the weights' submersion affects the load on the primary spring, ultimately triggering the switch to start the pump. The pump-down operation is the reverse process.
4. **Checking Switch Operation:** After installing the pump and switch, test the switch operation by running water into the sump. The pump should start when about half of the upper weight is submerged and stop when about half of the lower weight is out of the water. If the pump does not operate as expected, check for issues like blown fuses, tripped circuit breakers, or defective pumps.
5. **Dismantling for Cleaning or Parts Replacement:** If needed, you can dismantle the switch for cleaning or parts replacement. Follow the provided instructions to disassemble and reassemble the switch correctly.
By following these steps and referring to the detailed instructions in the manual, you can adjust and ensure the proper operation of the ALC control switch for your sump pump system.