To properly install and use the Kemo M204 Power Regulator Component for heaters, follow these steps based on the provided manual:
1. **Mounting and Ventilation:**
- Ensure the module is mounted in a well-ventilated place as it may heat up during operation.
- If the metal case heats up to more than 60°C, consider using an additional heat sink or a small ventilator.
- Proper ventilation is crucial for normal operation up to 1000 W.
2. **Safety Regulations:**
- The module should only be installed by an expert, such as an electrician, following the safety regulations of the VDE.
- Make sure live contacts are not accessible to fingers.
- The potentiometer is fully insulated for safety.
- Secure cables against unintentional pulling out with strain relief.
3. **Earthing:**
- If necessary, earth the case by scraping off the black color at one fixing hole and connecting a cable-fastening eye with a cable for earthing.
4. **Technical Specifications:**
- Operating voltage: 220 - 240 V/AC, 50 - 60 Hz
- Output voltage: pulsating, approx. 0.8 Hz with adjustable pulse length
- Max. current carrying capacity: approx. 16 A
- Connection: via flat plug 6.3 mm
- Current consumption without load: approx. 0.3 W
- Regulation via connected potentiometer: approx. 0 - 100%
- Operation display: with installed LED
- Dimensions: approx. 55 x 50 x 36 mm
5. **Important Notes:**
- Read the "General Information" in the printed matter no. M1002 attached for additional safety instructions.
- Avoid false connection, short-circuit, overload, too high operating voltage, or insufficient ventilation to prevent damage to the module.
By following these installation and usage guidelines as per the manual, you can effectively regulate heatings using the Kemo M204 Power Regulator Component.