Product Information

UPI-5D Universal Process Indicator with Enhanced Features

The UPI-5D is a process indicator with enhanced features that can display and monitor various input types. It has operator parameters, alarm parameters, retransmission parameters, input configuration parameters, and supervisory parameters. The device has adjustable alarm setpoints and hysteresis, alarm inhibition, alarm logic, and alarm latch functionality. It also has retransmission output options, square root selection, constant multiplier and resolution settings, and digital filtering capabilities. The UPI-5D comes with a brief operation manual for quick reference.

Product Usage Instructions

  1. Operator Parameters: Use PAGE 0 to adjust the maximum and minimum process values, reset command, reset password, and alarm setpoints.
  2. Alarm Parameters: Use PAGE 10 to adjust the alarm types, setpoints, hysteresis, inhibition, logic, and latch functionality for Alarm-1 and Alarm-2.
  3. Retransmission Parameters: Use PAGE 11 to adjust the retransmission output type, low and high values, and selected input type.
  4. Input Configuration Parameters: Use PAGE 12 to adjust the square root selection, constant multiplier and resolution settings, input type, resolution, units, signal low and high values, DC range low and high values, offset, and digital filter.
  5. Supervisory Parameters: Use PAGE 13 to enable or disable alarm SP adjustment on the operator page and remote alarm acknowledge switch.
  6. For more details on operation and application: Please log on to www.ppiindia.net

PARAMETERS

OPERATOR PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 1

ALARM PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 2 PPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 2

RETRANSMISSION PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 4

INPUT CONFIGURATION PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 5 PPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 6PPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 7

SUPERVISORY PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 8 PPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 9

USER LINEARISATION PARAMETERSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 10

TABLE 1PPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 11

FRONT PANEL LAYOUT

Front PanelPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 12

Keys OperationPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 13

PV Error IndicationsPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 14

ELECTRICAL CONNECTIONSPPI-UPI-5D-Universal-Process-Indicator-and-Controller-fig 15

This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net

101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar – 401 210.
Sales : 8208199048 / 8208141446
Support : 07498799226 / 08767395333
E: sales@ppiindia.net
support@ppiindia.net

Documents / Resources

PPI UPI-5D Universal Process Indicator and Controller [pdf] Instruction Manual
UPI-5D Universal Process Indicator and Controller, UPI-5D, Universal Process Indicator and Controller, Process Indicator and Controller, Indicator and Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *