Neuro 200 Advanced Universal Process Indicator
Instruction Manual
This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net
OPERATOR PAGE AND PARAMETERS
Parameters | Settings (Default Value) |
Alarm Acknowledge![]() | ![]() ![]() (Default : No) |
Maximum PV![]() | View Only (Default : NA) |
Minimum PV![]() | View Only (Default : NA) |
Reset Command![]() | ![]() ![]() (Default : No) |
Reset Password![]() | 0 to 250 (Default : 0) |
Alarm-1 Setpoint ![]() | Min to max Range specified for the selected Input Type (Default: Min or Max Range) |
Alarm-2 Setpoint ![]() | Min to max Range specified for the selected Input Type (Default : Min or Max Range) |
ALARM PARAMETERS
Parameters | Settings (Default Value) |
Alarm-1 Type![]() | ![]() ![]() ![]() (Default : None) |
Alarm-1 Setpoint![]() | Min to max Range specified for the selected Input Type (Default : Min or Max Range) |
Alarm-1 Hysteresis ![]() | 1 to 999 or 0.1 to 999.9 (Default : 2.0) |
Alarm-1 Inhibit ![]() | ![]() ![]() (Default : Yes) |
Alarm-1 Logic![]() | ![]() ![]() (Default : Normal) |
Alarm Latch![]() | ![]() ![]() (Default : No) |
Alarm-2 Type ![]() | ![]() ![]() ![]() (Default : None) |
Alarm-2 Setpoint ![]() | Min to max Range specified for the selected Input Type (Default : Min or Max Range) |
Alarm-2 Hysteresis ![]() | 1 to 999 or 0.1 to 999.9 (Default : 2.0) |
Alarm-2 Inhibit ![]() | ![]() ![]() (Default : Yes) |
Alarm-2 Logic ![]() | ![]() ![]() (Default : Normal) |
Alarm Latch ![]() | ![]() ![]() (Default : No) |
RE TRANSMISSION PARAMETERS
Parameters | Settings (Default Value) |
Recorder Output Type![]() | ![]() ![]() ![]() ![]() (Default : 0 to 20mA) |
Recorder Low![]() | Min. to Max. Range specified for the selected Input Type (Default : -200) |
Recorder High ![]() | Min. to Max. Range specified for the selected Input Type (Default : 1376) |
INPUT CONFIGURATION PARAMETERS
Parameters | Settings (Default Value) | |||||||||||||||||||||||||||
Input Type ![]() | Refer Table 2 (Default : Type K) | |||||||||||||||||||||||||||
Units ![]() | Refer Table 1 (Default : ºC) | |||||||||||||||||||||||||||
Signal Range Low ![]() |
| |||||||||||||||||||||||||||
Signal Range High![]() |
| |||||||||||||||||||||||||||
Resolution![]() | Refer Table 2 (Default : 1) | |||||||||||||||||||||||||||
DC Range Low![]() | -1999 to 9999 (Default : 0.0) | |||||||||||||||||||||||||||
DC Range High![]() | -1999 to 9999 (Default : 100.0) | |||||||||||||||||||||||||||
Offset![]() | -1999 to 9999 or -199.9 to 999.9 (Default : 0) | |||||||||||||||||||||||||||
Filter![]() | 0.5 to 60.0 Seconds (in steps of 0.5 Seconds) (Default : 2.0 sec.) |
SUPERVISORY PARAMETERS
Parameters | Settings (Default Value) |
Alarm SP Adjustment on Operator Page![]() | ![]() ![]() (Default : Disable) |
Process Value High-Low Monitoring![]() | ![]() ![]() (Default : No) |
Password for Resetting PV High-Low ![]() | 0 to 250 (Default : 0) |
Serial ID Number![]() | 1 to 127 (Default : 1) |
Baud Rate![]() | ![]() ![]() ![]() (Default : 9.6) |
Parity ![]() | ![]() ![]() ![]() (Default : Even) |
Serial Write Permission ![]() | ![]() ![]() (Default : Yes) |
USER LINEARISATION PARAMETERS
Parameters | Settings (Default Value) |
User Linearization Setting Code ![]() | 0 to 9999 (Default : 0) |
User Linearization ![]() | ![]() ![]() (Default : No) |
Total Break Points ![]() | 2 to 32 (Default : 2) |
Break Point Number ![]() | 1 to 32 (Default : 1) |
Actual Value for Break Point (X co-ord)![]() | -1999 to 9999 (Default : Undefined) |
Derived Value for Break Point (Y co-ord) ![]() | -1999 to 9999 (Default : Undefined) |
TABLE- 1
Lower Readout | Units | |
![]() | °C | Temperature |
![]() | °F | |
![]() | Kelvin | |
![]() | Engineering Units | |
![]() | Percentage | |
![]() | Pascals | Pressure |
![]() | Mpascals | |
![]() | Kpascals | |
![]() | Bar | |
![]() | Milli bar | |
![]() | PSI | |
![]() | kg/sq cm | |
![]() | mm water gauge | Pressure |
![]() | Inches water gauge | |
![]() | mm mercury | |
![]() | Torr | |
![]() | Litres per hour | Flow |
![]() | Litres per minute | |
![]() | % Relative Humidity | |
![]() | % O2 | |
![]() | % CO2 | |
![]() | % Carbon Potential | |
![]() | volts | Electricity |
![]() | Amps | |
![]() | Milli amps | |
![]() | Milli Volts | |
![]() | Ohms | |
![]() | Parts per million | |
![]() | Revolutions per pinute | |
![]() | Milli seconds | Time |
![]() | Seconds | |
![]() | Minutes | |
![]() | Hours | |
![]() | PH | |
![]() | %PH | |
![]() | Miles per hour | |
![]() | Milli grams | Weight |
![]() | Grams | |
![]() | Kilo grams |
Lower Readout | Units | |
![]() | mm (Millimeter) | Length/Height/Distance |
![]() | cm (Centimeter) | |
![]() | Meter | |
![]() | Kilometre | |
![]() | Foot | |
![]() | Inch | |
![]() | Mile |
Table 2
Option | What it means | Range (Min. to Max.) | Resolution |
![]() | Type J Thermocouple | 0 to +960°C / +32 to +1760°F | Fixed 1°C/1°F |
![]() | Type K Thermocouple | -200 to +1376°C / -328 to +2508°F | |
![]() | Type T Thermocouple | -200 to +385°C / -328 to +725°F | |
![]() | Type R Thermocouple | 0 to +1770°C / +32 to +3218°F | |
![]() | Type S Thermocouple | 0 to +1765°C / +32 to +3209°F | |
![]() | Type B Thermocouple | 0 to +1825°C / +32 to +3092°F | |
![]() | Type N Thermocouple | 0 to +1300°C / +32 to +2372°F | |
![]() | Reserved for customer specific Thermocouple type not listed above. The type shall be specified in accordance with the ordered (optional on request) Thermocouple type. | ||
![]() | 3-wire, RTD Pt100 | -199 to +600°C/-328 to +1112°F or -199.9 to 600.0°C/-199.9 to 999.9°F | User settable 1°C/1°F or 0.1°C/0.1°F |
![]() | 0 to 20mA DC current | -1999 to +9999 units | User settable 1 / 0.1 / 0.01/ 0.001 units |
![]() | 4 to 20mA DC current | ||
![]() | Reserved | ||
![]() | 0 to 80 mV DC voltage | ||
![]() | 0 to 1.25V DC voltage | ||
![]() | 0 to 5.0V DC voltage | ||
![]() | 0 to 10.0V DC voltage | ||
![]() | 1 to 5.0V DC voltage |
FRONT PANEL LAYOUT
Keys Operation
Symbol | Key | Function |
![]() | PAGE | Press to enter or exit set-up mode. |
![]() | DOWN | Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. |
![]() | UP | Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. |
![]() | ENTER/ACK | Set up Mode: Press to store the set parameter value and to scroll to the next parameter on the PAGE. Run Mode: Press to acknowledge any pending Alarm(s). This also turns off the Alarm relay. |
PV Error Indications
Message | PV Error Type |
![]() | Over-range (PV above Max. Range) |
![]() | Under-range (PV below Min. Range) |
![]() | Open (Sensor open/broken) |
ELECTRICAL CONNECTIONS
101, Diamond Industrial Estate, Navghar,
Vasai Road (E), Dist. Palghar – 401 210.
Sales: 8208199048/8208141446
Support: 07498799226/08767395333
E: sales@ppiindia.net
support@ppiindia.net
Dec 2021