Product Information

The Top Loading Bottle Cooler is a product designed to keep bottles cool. It comes in three different models: CT330-A with a width of 935mm, CT331-A with a width of 1255mm, and CT332-A with a width of 1634mm. The product is packaged with all necessary components and is designed to be operated with a minimum clearance of 2.5cm between the unit and walls or other objects. The product has a control panel that allows you to set the operating temperature and manually defrost the unit. The appliance must be cleaned regularly for optimal performance.

Product Usage Instructions
Before using the Top Loading Bottle Cooler, please read the instruction manual carefully. The correct maintenance and operation of the machine will provide the best possible performance from your POLAR product.

Installation

  1. Remove the appliance from the packaging and ensure all protective plastic film and coatings are removed from all surfaces.
  2. Ensure a minimum clearance of 2.5cm is maintained between the unit and walls or other objects, with a minimum 5cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.
  3. Level the appliance by adjusting the screw feet.
  4. Clean the interior with soapy water before using the appliance for the first time.

Operation

To set the operating temperature:

  1. Hold the SET button for 3 seconds. The value of the current set point will be displayed.
  2. Press the or buttons to display the required temperature.
  3. Press the SET button to store the temperature.

To manually defrost the unit:

  1. Press and hold the defrost button aux for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Condensation will form in refrigeration on hot humid days, please ensure condensation is allowed to drain properly or is wiped dry.
Clean the condenser regularly for optimal performance.

Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer. A POLAR agent or qualified technician must carry out repairs if required.

FaultProbable CauseSolution
The appliance is not workingThe unit is not switched onCheck the unit is plugged in correctly and switched on
Plug or lead is damagedReplace plug or lead
Mains power supply faultCheck mains power supply
The appliance turns on, but the temperature is too
high/low
Too much ice on the evaporator or condenser blocked with dust
or doors are not shut properly
Clean the condenser and ensure doors are shut properly

Safety Instructions

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

  • Position on a flat, stable surface.
  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
  • Consult Local and National Standards to comply with the following:
    • Health and Safety at Work Legislation
    • Fire Precautions
    • Wiring Regulations
    • Building Regulations
  • DO NOT use jet/pressure washers to clean the appliance.
  • DO NOT use the appliance outside.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT stand or support yourself on the base, drawers or doors.
  • DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.
  • Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the refrigerator.
  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
  • Always switch off and disconnect the power supply to the unit before cleaning.
  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • POLAR recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.

Caution:
Risk of FirePOLAR-CT330-A-Top Loading-Bottle-Cooler-01

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
    Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.
  • Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Warning: Do not damage the refrigerant circuit.
  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.

Product Description

  • CT330-A – Polar Top loading Bottle cooler – 935mm Width
  • CT331-A – Polar Top loading Bottle cooler – 1255mm Width
  • CT332-A – Polar Top loading Bottle cooler – 1634mm Width

Pack Contents
The following is included:

  • POLAR Refrigerator
  • Instruction Manual

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.

  1. Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces.
  2. To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 5cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.
  3. Level the appliance by adjusting the screw feet.

Operation

Control PanelPOLAR-CT330-A-Top Loading-Bottle-Cooler-02

Set the Operating Temperature

  1. Hold the SET button for 3 seconds. The value of the current set point will be displayed.
  2. Press the POLAR-CT330-A-Top Loading-Bottle-Cooler-03 buttons to display the required temperature.
  3. Press the SET button to store the temperature.

Manual Defrost
Press and hold the defrost button “aux” for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care & Maintenance

Switch off and disconnect from the power supply before cleaning.

  • Clean the interior of the appliance as often as possible.
  • Do not use abrasive cleaning agents. These can leave harmful residues.
  • Clean the door seal with warm soapy water.
  • Always wipe dry after cleaning.
    Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
    Take care when cleaning the rear of the appliance. Sharp edges can cut.

Note: Condensation will form in refrigeration on hot humid days, please ensure condensation is allowed to drain properly or is wiped dry.

Cleaning the Condenser

  • Periodically cleaning the condenser can extend the life of the appliance.
  • POLAR recommend that a POLAR agent or qualified technician clean the condenser.

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer. A POLAR agent or qualified technician must carry out repairs if required.

FaultProbable CauseSolution
The appliance is not workingThe unit is not switched onCheck the unit is plugged in correctly and switched on
Plug or lead is damagedReplace plug or lead
Mains power supply faultCheck mains power supply
The appliance turns on, but the temperature is too high/lowToo much ice on the evaporatorDefrost the appliance
Condenser blocked with dustCall POLAR agent or qualified Technician
Doors are not shut properlyCheck doors are shut and seals are not damaged
Appliance is located near a heat source or air flow to the condenser is being interruptedMove the refrigerator to a more suitable location
Ambient temperature is too highIncrease ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the applianceRemove any excessive hot foodstuffs or blockages to the fan
Appliance is overloadedReduce the amount of food stored in the appliance
The appliance is leaking waterThe appliance is not properly levelledAdjust the screw feet to level the appliance (if applicable)
The discharge outlet is blockedClear the discharge outlet
Movement of water to the drain is obstructedClear the floor of the appliance (if applicable)
The water container is damagedCall POLAR agent or qualified Technician
The drip tray is overflowingEmpty the drip tray (if applicable)
The appliance is unusually loudLoose nut/screwCheck and tighten all nuts and screws
The appliance has not been installed in a level or stable positionCheck installation position and change if necessary

Technical Specifications

ModelVoltagePowerCurrentTemperature RangeRefrigerantDimensions H x W x D mmWeight (kg)
CT330-A220-240V~

50Hz

160W1.4A2°C ~ 8°CR600a 55g888 x 935 x 68752.5
CT331-A250W1.4A2°C ~ 8°CR600a 60g888 x 1255 x 68767
CT332-A250W1.4A2°C ~ 8°CR600a 60g888 x 1634 x 68778

Electrical Wiring
The plug is to be connected to a suitable mains socket. This appliance is wired as follows:

  • Live wire (colored brown) to terminal marked L
  • Neutral wire (colored blue) to terminal marked N
  • Earth wire (colored green/yellow) to terminal marked Ez

The appliances must be earthed.POLAR-CT330-A-Top Loading-Bottle-Cooler-04
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance
The product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.POLAR-CT330-A-Top Loading-Bottle-Cooler-05

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY

Equipment TypeModel
G-Series Top loading Bottle cooler – 935mm Width G-Series Top loading Bottle cooler – 1255mm Width G-Series Top loading Bottle cooler – 1634mm WidthCT330 (& -E -A)

CT331 (& -E -A)

CT332 (& -E -A)

Application of Territory LegislationMachinery Directive 2006/42/ECElectrical Safety
& Council Directives(s)EN 60335-1:2012 +A11:2014 +A13:2017IEC 60335-1:2010 +A1:2013 +A2:2015
Toepassing van EuropeseEN 60335-2-89:2010 +A1:2016 +A2:2017IEC 60335-2-89:2010 +A1:2012 +A2:2016
EN 62233:2008
directive(s)
Electro-Magnetic Compatibility (EMC)Electromagnetic Compatibility
DirettiveDirective 2014/30/EU – recast of 2004/108/ECEN 55014-1:2017
EN 55014-1:2017EN 55014-2:2015
EN 55014-2:2015EN 61000-3-2: 2014
ConselhoEN 61000-3-2: 2014EN 61000-3-3: 2013
EN 61000-3-3: 2013
Restriction of Hazardous Substances Directive
(RoHS) 2015/863 amending Annex II to
Directive 2011/65/EU
Producer NamePolar

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

  • Date  : 3rd December 2020
  • Signature: ___________
  • Full Name : Ashley Hooper
  • Position:  Technical & Quality Manager
    Commercial
    Manager/ Importer
    Commercial Manager/ Responsible Supplier
  • Producer Address:  Fourth Way,
    Fourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom
    42 North Point Business Park New Mallow Road Cork Ireland
    15 Bagdally Road, Campbelltown NSW 2560

POLAR-CT330-A-Top Loading-Bottle-Cooler-06

Documents / Resources

POLAR CT330-A Top Loading Bottle Cooler [pdf] Instruction Manual
CT330-A Top Loading Bottle Cooler, CT330-A, Top Loading Bottle Cooler, Loading Bottle Cooler, Bottle Cooler

References

Leave a comment

Your email address will not be published. Required fields are marked *