VEVOR Bottled Water Dispensing Pump System

VEVOR Bottled Water Dispenser Pump System (Double-Pipe) Instruction Manual

Model: Bottled Water Dispensing Pump System

Wstęp

This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your VEVOR Double-Pipe Bottled Water Dispenser Pump System. Please read this manual thoroughly before use and retain it for future reference.

Cechy produktu

  • Dual-Tube System: Designed for two 5-gallon bottled water containers, extending usage cycles and reducing water change frequency.
  • Wysoka wydajność: Operates at 40-60 PSI (2.8-4.1 bar) with a water outlet flow rate of 0.67 GPM (2.5 L/min) for consistent water supply.
  • Szerokie zastosowanie: Suitable for providing clean water to faucets, refrigerators, ice makers, and coffee machines.
  • Dual Switch Protection: Features a buoyancy switch for automatic shut-off when bottles are empty and a water pressure switch for automatic water supply upon faucet opening.
  • Cicha praca: Equipped with 4 shock-absorbing pads to minimize noise during use.

Instrukcje bezpieczeństwa

  • Ensure the power supply matches the product's voltage (110 woltów).
  • Always turn off the dispenser when changing water bottles.
  • Nie należy uruchamiać pompy na sucho przez dłuższy okres czasu.
  • Trzymaj urządzenie z dala od źródeł ciepła i bezpośredniego światła słonecznego.
  • Use only food-grade tubing and connectors for water contact.
  • Regularly inspect all connections for leaks.

Zawartość opakowania

  • Bottled Water Dispensing System Unit
  • 1/4" PE Tube (Length: 19.69 ft / 600 cm)
  • Pre-installed Quick Connect (x1)
  • Connector Nut (x1)
  • Pierścień uszczelniający (x1)
  • Silicone Foot Pads (x4)

Konfiguracja i instalacja

Follow these steps for proper installation of your VEVOR Bottled Water Dispenser Pump System.

1. Rozpakowanie i ustawienie

  • Ostrożnie wyjąć wszystkie elementy z opakowania.
  • Choose a suitable location for the pump unit and water bottles. Ensure there is enough space for two 5-gallon bottles and that the pump unit is mounted securely.
VEVOR Bottled Water Dispenser Pump System installed under a counter with two 5-gallon water bottles.
The VEVOR Bottled Water Dispenser Pump System installed under a kitchen counter, showing the pump unit mounted on the wall and two 5-gallon water bottles connected.
Diagram showing the VEVOR Bottled Water Dispensing System connected to a coffee maker and two bottled water containers.
An illustrative diagram demonstrating the connection of the bottled water dispensing system to a coffee maker and two bottled water containers.

2. Connecting the Tubing

  • Insert the long intake tubes into the 5-gallon water bottles. Ensure the tubes reach the bottom of the bottles.
  • Connect the other end of the intake tubes to the designated inlet ports on the pump unit.
  • Connect the 1/4" PE tube from the pump's outlet port to your appliance (e.g., refrigerator, coffee machine, faucet). Use the provided quick connect and sealing ring for a secure, leak-free connection.
Step-by-step guide for installing the VEVOR Bottled Water Dispenser Pump System, showing placement, accessory installation, hose placement, and power connection.
A visual guide illustrating the installation process, including preparing space, installing accessories, placing the water pump hose into the bottled water, and connecting to power.

3. Podłączenie zasilania

  • Podłącz przewód zasilający do standardowego gniazdka elektrycznego 110 V.

Działanie

The VEVOR Bottled Water Dispenser Pump System is designed for automatic operation.

  • Włączanie: Flip the power switch on the pump unit to the "ON" position. The pump will pressurize the system.
  • Dozowanie wody: When your connected appliance (e.g., refrigerator dispenser, coffee machine) demands water, the pump will automatically activate to supply water.
  • Automatyczne wyłączanie: The built-in buoyancy switch will detect when a water bottle is empty and automatically stop the pump to prevent dry running.
  • Pressure Maintenance: The water pressure switch maintains consistent pressure in the line, ensuring a steady flow when needed.
Diagram illustrating the dual-switch intelligent protection system of the VEVOR water dispenser, showing water pressure switch, buoyancy switch, and built-in backflow prevention valve.
An illustration detailing the dual-switch intelligent protection, including the water pressure switch for automatic supply and the buoyancy switch for empty bottle detection, along with a backflow prevention valve.

Konserwacja

Regularna konserwacja zapewnia optymalną wydajność i długą żywotność dozownika.

  • Changing Water Bottles: Always turn off the pump unit before replacing empty water bottles. This prevents air from entering the system and ensures proper priming.
  • Czyszczenie: Periodically clean the exterior of the pump unit with a damp ściereczka. Nie używaj środków czyszczących o właściwościach ściernych.
  • Inspekcja rur: Inspect the PE tubing for any kinks, cracks, or signs of wear. Replace if necessary.
  • Płukanie systemu: If the system has been idle for an extended period, flush a small amount of water through it before use.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Pompa nie działaNo power; Power switch off; Empty water bottle; Loose connection.Check power cord and outlet; Turn on power switch; Replace water bottle; Secure all electrical and tubing connections.
Niski przepływ wodyKinked tubing; Partially empty bottle; Air in the system; Clogged filter on intake tube.Straighten tubing; Replace water bottle; Turn off and on to re-prime; Clean or replace intake filter.
Pompa pracuje w sposób ciągłyLeak in the system; Air leak in intake tube; Faulty pressure switch.Check all connections for leaks; Ensure intake tubes are fully submerged and sealed; Contact customer support if switch is faulty.
Niezwykły hałasVibration; Air in the system; Obstruction in pump.Ensure pump is securely mounted; Check for air in lines; Inspect pump for foreign objects (unplug first).

Specyfikacje

FunkcjaSzczegół
MarkaWIĘZIĆ
Numer modeluBottled Water Dispensing Pump System
StylDouble Inlet
Moc znamionowa50 W
Zakres ciśnienia roboczego40-60 psi (2.8-4.1 bar)
Water Outlet Flow Rate> 0.67 GPM / > 2.5 L/min
Pump Head Flow Rate> 1 GPM / > 3.8 L/min
Tomtage110 wolty
Wymiary produktu5.5" gł. x 2.8" szer. x 7.9" wys. (14 cm gł. x 7.1 cm szer. x 20.1 cm wys.)
Waga przedmiotu5.98 funtów (2.71 kg)
TworzywoPlastikowy
Typ instalacjiSamodzielny
Źródło zasilaniaElektryczny przewodowy
Detailed product specifications for the VEVOR Bottled Water Dispenser Pump System, including dimensions, flow rates, and included accessories.
A visual representation of the product specifications, including dimensions of the pump unit and lengths of tubing, along with a list of included accessories.

Gwarancja i wsparcie

VEVOR products are designed for durability and performance. For technical support, warranty information, or any inquiries, please visit the official VEVOR support webstrona: www.vevor.com/support.

Proszę zachować paragon zakupu na wypadek reklamacji.