Tomasz 5012

Thomas 5012 Traceable Multi-Colored Timer Instruction Manual

Model: 5012

Wstęp

The Thomas 5012 Traceable Multi-Colored Timer is a versatile 4-channel timer designed for precise timekeeping in various environments. It features a clear digital display, multiple timing functions, and customizable colored frames to suit individual preferences. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance of your timer.

Thomas 5012 Traceable Multi-Colored Timer with blue and grey casing, showing a digital display with '93:1120' and 'T4' visible.

Figure 1: Thomas 5012 Traceable Multi-Colored Timer. This image displays the front view of the timer, highlighting its digital screen, control buttons for hours, minutes, seconds, clear, clock, and four timer channels (T1-T4), along with the start/stop/memory button.

Główne cechy

  • 4-Channel Timing: Independent countdown and count-up functions for four separate events.
  • Automatic Bounceback Memory: Recalls the last set time for repetitive timing.
  • Wysoka dokładność: 0.01 percent accuracy for precise measurements.
  • Wide Timing Range: Times up to 99 hours, 59 minutes, 59 seconds.
  • Time-of-Day Clock: Displays current time in 12 or 24-hour format.
  • Wszechstronne rozmieszczenie: Features an easel bench stand and magnetic back for flexible positioning.
  • Możliwość dostosowania wyglądu: Includes three bright, colorful frames for personalization.
  • NIST Traceability: Supplied with an individually serial-numbered traceable certificate from an ISO 17025 calibration laboratory.

Organizować coś

1. Instalacja baterii

The Thomas 5012 Timer requires batteries for operation. Locate the battery compartment on the back of the unit. Insert the required batteries, ensuring correct polarity (+/-). Close the battery compartment securely.

2. Attaching Color Frames

Your timer comes with assorted colorful frames. To personalize your timer, gently snap the desired colored frame onto the front of the timer until it is securely in place.

3. Opcje rozmieszczenia

  • Easel Bench Stand: Pull out the integrated stand on the back of the timer to prop it up on a flat surface.
  • Magnetyczny tył: The timer features a magnetic back, allowing it to be securely attached to metallic surfaces such as refrigerators or lab equipment.

Instrukcja obsługi

1. Setting the Time-of-Day Clock

  1. Naciśnij ZEGAR button to enter clock setting mode.
  2. Użyj H (Hours), M (Minutes), and S (Seconds) buttons to adjust the current time.
  3. Naciskać ZEGAR again to exit setting mode and save the time. The clock supports both 12-hour and 24-hour formats.

2. Using the Timer Channels (T1, T2, T3, T4)

The timer has four independent channels. Each channel can be used for countdown or count-up timing.

Setting a Countdown Timer:

  1. Select the desired channel (e.g., T1) by pressing its respective button. The display will show the selected channel.
  2. Użyj H, M, I S buttons to set the desired countdown time (up to 99 hours, 59 minutes, 59 seconds).
  3. Naciśnij START/STOP MEMORY przycisk, aby rozpocząć odliczanie.
  4. When the timer reaches zero, an alarm will sound, and the timer will begin counting up, indicating the elapsed time since the alarm.
  5. Naciskać START/STOP MEMORY again to stop the alarm and the count-up.
  6. Press the channel button (e.g., T1) again to recall the original set time (Automatic Bounceback Memory).

Using as a Stopwatch (Count-Up Timer):

  1. Select the desired channel (e.g., T2) by pressing its respective button.
  2. Ensure the display for that channel shows "00:00:00". If not, press the JASNE przycisk, aby go zresetować.
  3. Naciśnij START/STOP MEMORY przycisk, aby rozpocząć odliczanie.
  4. Naciskać START/STOP MEMORY again to pause the count. Press it again to resume.
  5. Naciśnij JASNE przycisk, aby wyzerować stoper.

3. Clearing a Timer

To clear the time set on any channel, select the channel and then press the JASNE button. This will reset the channel to "00:00:00".

Konserwacja

Czyszczenie

Aby wyczyścić timer, przetrzyj go miękką szmatką.amp cloth. Do not use abrasive cleaners or immerse the unit in water. Ensure the unit is dry before storage or continued use.

Wymiana baterii

When the display dims or the timer functions become erratic, it is time to replace the batteries. Refer to the "Battery Installation" section under Setup for instructions.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Timer nie włącza się lub wyświetlacz jest przyciemniony.Niski poziom naładowania baterii lub rozładowane baterie; nieprawidłowa instalacja baterii.Wymień baterie na nowe, zwracając uwagę na prawidłową biegunowość.
Trudno jest naciskać przyciski lub nie reagują one na nie.Debris under buttons; internal malfunction.Ensure buttons are clean. If issue persists, contact customer support.
Timer does not start after pressing START/STOP.Time not set; button not fully pressed; internal issue.Ensure a time is set for countdown. Press the START/STOP button firmly. If problem continues, contact customer support.
Alarm nie włącza się.Niski poziom naładowania baterii; awaria wewnętrzna.Wymień baterie. Jeśli problem będzie się powtarzał, skontaktuj się z obsługą klienta.

Specyfikacje

  • Numer modelu: 5012
  • Wymiary: 0.5" gł. x 2.25" szer. x 2.75" wys. (1.27 cm gł. x 5.72 cm szer. x 6.99 cm wys.)
  • Waga: Około 3.2 uncji (90.7 gramów)
  • Zakres czasowy: 99 godzin, 59 minut, 59 sekund
  • Rezolucja: 1 sekunda
  • Dokładność: 0.01 procent
  • Kanały: 4 independent timing channels
  • Zegar: Format 12/24-godzinny
  • Źródło zasilania: Battery (type not specified, assume common AAA or button cell)
  • Kraj pochodzenia: Chiny

Gwarancja i wsparcie

The Thomas 5012 Traceable Multi-Colored Timer is supplied with an individually serial-numbered traceable certificate from an ISO 17025 calibration laboratory accredited by A2LA. This certificate indicates traceability to standards provided by NIST (National Institute of Standards and Technology), assuring accuracy.

For warranty information, technical support, or service inquiries, please contact Thomas Scientific directly. Refer to their official webAktualne dane kontaktowe można znaleźć na stronie internetowej lub opakowaniu produktu.

Note: Keep your traceable certificate in a safe place for future reference.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.