Leviton 25249-TFB

Leviton 25249-TFB 15 Amp 125 Volt TampInstrukcja obsługi gniazda dupleksowego odpornego na er

Model: 25249-TFB

Wstęp

This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton 15 Amp, 125 Volt, Tamper-Resistant Duplex Receptacle (Model 25249-TFB). This commercial-grade, self-grounding receptacle features a straight blade design and a brass finish, engineered for demanding environments such as hotels, schools, hospitals, and commercial office buildings. It is designed to withstand rigorous use and offers enhanced safety features.

Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Ostrzeżenie dotyczące propozycji 65: Ten produkt może zawierać substancje chemiczne, o których stan Kalifornia wie, że powodują raka i wady wrodzone lub inne szkody reprodukcyjne. Umyj ręce po kontakcie.

  • Nie używaj tego urządzenia z przewodami aluminiowymi. Używaj wyłącznie z przewodami miedzianymi lub miedziowanymi.
  • Sprawdź, czy wszystkie połączenia są dobrze dokręcone i bezpieczne, aby zapobiec przegrzaniu.
  • This receptacle is tamper-resistant, designed to prevent insertion of foreign objects into the receptacle openings.
  • Do not exceed the specified electrical ratings of 15 Amps and 125 Volts.

Cechy produktu

  • TampKonstrukcja odporna na er: Meets NEC 2020 article 406.12, providing enhanced safety by preventing the insertion of single objects into the receptacle openings.
  • Klasa komercyjna: Built to withstand demanding environments, ensuring durability and long-term performance.
  • Samouziemienie: Features an integral self-grounding clip for quick and easy installation into a properly grounded metal box.
  • Trwała konstrukcja: Thermoplastic receptacle face and body resist breakage.
  • Ready-To-Wire Unit: All-in-one design facilitates quick and easy installation.
Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish

Image: Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish. This image shows the front view of the receptacle with its brass faceplate and two tampgniazdka odporne na er.

Konfiguracja i instalacja

Installation of electrical devices should only be performed by qualified personnel. Always ensure power is disconnected before beginning any work.

  1. Wyłącz zasilanie: Locate the circuit breaker or fuse that supplies power to the outlet where the receptacle will be installed. Turn it off and verify that power is off using a voltagtester.
  2. Remove Old Receptacle (if applicable): Carefully remove the existing wall plate and receptacle from the electrical box. Disconnect the wires, noting their connections (hot, neutral, ground).
  3. Przygotuj przewody: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight.
  4. Podłącz przewody:
    • Połącz gorący (czarny) wire to the brass-colored screw terminal.
    • Połącz neutralny (biały) wire to the silver-colored screw terminal.
    • Połącz ground (green or bare copper) wire to the green screw terminal. This receptacle is self-grounding, meaning it will ground itself to a properly grounded metal box via its mounting strap.
    Sprawdź, czy wszystkie połączenia przewodów są solidne i bezpieczne.
  5. Gniazdo montażowe: Carefully fold the wires into the electrical box, then insert the new receptacle and secure it with the mounting screws provided.
  6. Zainstaluj płytę ścienną: Attach the decorative wall plate (sold separately) over the receptacle.
  7. Przywróć zasilanie: Włącz ponownie zasilanie za pomocą wyłącznika obwodu lub skrzynki bezpiecznikowej.
  8. Test: Test the receptacle with a known working appliance or receptacle tester to ensure proper function.
Leviton 25249-TFB Receptacle Back View

Obraz: Tył view of the Leviton 25249-TFB receptacle, showing the screw terminals for wiring connections (hot, neutral, ground).

Instrukcja obsługi

The Leviton 25249-TFB Tamper-Resistant Duplex Receptacle operates like a standard electrical outlet, with added safety features.

  • Podłączanie: Insert the plug of your appliance or device firmly into one of the two receptacle openings. The tamper-resistant shutters may require slightly more force to open than a traditional receptacle. Ensure both prongs are inserted simultaneously and evenly.
  • Odłączanie: Grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
  • Nośność: Do not overload the receptacle. The total current drawn by all connected devices should not exceed 15 Amps.

Konserwacja

The Leviton 25249-TFB receptacle requires minimal maintenance.

  • Czyszczenie: To clean the receptacle face, ensure power is off at the circuit breaker. Use a soft, damp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Kontrola: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and have the receptacle inspected and replaced by a qualified electrician.
  • Zagadnienia dotyczące ochrony środowiska: While durable, avoid exposing the receptacle to excessive moisture or extreme temperatures beyond its operational specifications.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Brak zasilania w pojemniku.Circuit breaker tripped or fuse blown. Loose wiring connection.Check and reset the circuit breaker or replace the fuse. If problem persists, turn off power and check wiring connections. Consult an electrician if necessary.
Plug does not insert easily.Tamper-resistant shutters are engaged.Ensure both prongs of the plug are aligned and inserted simultaneously and firmly. Do not force the plug.
Receptacle feels warm.Overloaded circuit. Loose wiring connection.Unplug some devices to reduce load. Turn off power and check wiring connections. If warmth persists, consult an electrician immediately.

Specyfikacje

  • Model: 25249-TFB
  • Ampwymazać: 15 Amps
  • Tomtage: 125 wolty
  • Konfiguracja: 5-15R
  • Liczba biegunów: 2
  • Liczba przewodów: 3
  • Grunt: Samouziemienie
  • Tworzywo: Nylon (body), Brass (finish)
  • Kolor: Mosiężne wykończenie
  • Normy i certyfikaty: UL 498, CSA C22.2, NOM 057 Approved
  • Całkowita liczba gniazd zasilających: 2

Gwarancja i wsparcie

Gwarancja: This Leviton product is backed by a 10-Year Limited Warranty. For detailed warranty terms and conditions, please refer to the official Leviton webodwiedź witrynę lub skontaktuj się z działem obsługi klienta.

Obsługa klienta: For technical assistance, troubleshooting, or warranty claims, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the product packaging or the Leviton webstrona.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.