logo

PEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values

PEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values product-img..

Frequency Converter with Trip Values

KFD2-UFC-Ex1.D

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for NAMUR sensors or dry contacts
  • Input frequency 1 MHz … 5 kHz
  • Current output 0/4 mA … 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511

Function

  • This isolated barrier is used for intrinsic safety applications.
  • The device is a universal frequency converter that changes a digital input signal into a proportional free adjustable 0/4 mA … 20 mA analog output signal and functions as a switch amplifier and a trip alarm.
  • The functions of the switch outputs (2 relay outputs and 1 potential free transistor output) are easily adjustable [trip value display (min/max alarm), serially switched output, pulse divider output, error signal output].
  • The device is easily configured by the use of keypad or with the PACTware configuration software.
  • A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.
  • For additional information, refer to the manual and www.pepperl-fuchs.com.

ConnectionPEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (1)

Technical Data

General specifications
Signal type                                                                         Digital Input
Functional safety related parameters
Safety Integrity Level (SIL)                                                   SIL 2
Supply
Connection                                                                    terminals 23+, 24- or power feed module/Power Rail
Rated voltageUr20 … 30 V DC
Rated currentIrapprox. 100 mA
Power dissipation/power consumption ≤ 2 W / 2.2 W
Interface
Programming interface programming socket
Input
Connection side field side
Connection Input I: intrinsically safe: terminals 1+, 3-

Input II: non-intrinsically safe: terminals 13+, 14-

Input I                                                                               sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Pulse duration                                                              > 50 µs
Input frequency 0.001 … 5000 Hz
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II                                                                              startup override: 1 … 1000 s, adjustable in steps of 1 s
Active/Passive                                                            I > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit current 18 V / 5 mA
Output
Connection side control side
Connection output I: terminals 10, 11, 12

output II: terminals 16, 17, 18

outout III: terminasl 19+, 20-

output IV: terminals 8+, 7-

Output I, II                                                                       signal, relay
Contact loading                                                         253 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III                                                                          electronic output, passive
Contact loading                                                         40 V DC
Signal level 1-signal: (L+) – 2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current ≤ 10 µA)
Output IV analog
Current range                                                               0 … 20 mA or 4 … 20 mA
Open loop voltage                                                     max. 24 V DC
Load max. 650 Ω
Fault signal downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)
Collective error message                                             Power Rail
Transfer characteristics
Input I  
Measurement range 0.001 … 5000 Hz
Resolution                                                                  0.1 % of the measurement value , ≥ 0.001 Hz
Accuracy                                                                     0.1 % of the measurement value , > 0.001 Hz
Measuring time < 100 ms
Influence of ambient temperature 0.003 %/K (30 ppm)
Output I, II
Response delay                                                            ≤ 200 ms
Output IV  
Resolution < 10 µA
Accuracy                                                                     < 20 µA
Influence of ambient temperature                              0.005 %/K (50 ppm)
Galvanic isolation
Input I/other circuits                                                            reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective error              basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/start-up override                                                   basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output IV/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Start-up override/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/output III                                                             basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration                                                                via operating buttons

via PACTware

Labeling                                                                          space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage  
Directive 2014/35/EU                                                    EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Input                                                                               EN 60947-5-6:2000
Ambient conditions
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass                                                                               300 g
Dimensions                                                                    40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate TÜV 99 ATEX 1471
Marking 1 II (1)G [Ex ia Ga] IIC

1 II (1)D [Ex ia Da] IIIC

1 I (M1) [Ex ia Ma] I

Supply
Maximum safe voltage                                        Um        40 V DC (Attention! Um is no rated voltage.)
Input I terminals 1+, 3-: Ex ia
Voltage Uo 10.1 V
Current Io                                                                   13.5 mA
Power Po                                                                    34 mW (linear characteristic)
Input II terminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! The rated voltage can be lower.)
Output I, II                                                                       terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Maximum safe voltage                                        Um        253 V (Attention! The rated voltage can be lower.)
Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Output III terminals 19+, 20- non-intrinsically safe
Maximum safe voltage Um                             Um        40 V (Attention! Um is no rated voltage.)
Output IV                                                                           terminals 8+, 7- non-intrinsically safe
Maximum safe voltageUm40 V DC (Attention! Um is no rated voltage.)
Interface RS 232
Maximum safe voltage                                        Um        40 V (Attention! Um is no rated voltage.)
Certificate                                                                       TÜV 02 ATEX 1885 X
Marking 1 II 3G Ex nA nC IIC T4 Gc
Output I, II  
Contact loading                                                         50 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Galvanic isolation
Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity  
Directive 2014/34/EU                                                    EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval  
Control drawing 16-538FM-12
UL approval                                                                   E223772
IECEx approval
IECEx certificate IECEx TUN 04.0007 IECEx TSA 18.0007X
IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex ec nC IIC T4 Gc
General information
Supplementary information                                          Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

AssemblyPEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (2)

Matching System ComponentsPEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (3)PEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (4)

AccessoriesPEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (5)

Characteristic Curve

Maximum Switching Power of Output ContactsPEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values fig (6)

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Documents / Resources

PEPPERL FUCHS KFD2-UFC-Ex1.D Frequency Converter with Trip Values [pdf] Instruction Manual
KFD2-UFC-Ex1.D Frequency Converter with Trip Values, KFD2-UFC-Ex1.D, Frequency Converter with Trip Values, Trip Values, Values

References

Leave a comment

Your email address will not be published. Required fields are marked *