Step-by-Step Installation Instructions

In this Quick Start Guide, you will learn how to set up the TWR-MPC5125 module and run the default demonstration software. The following instructions are for Windows® X P.

STEP 1
Connect the HDMI cable
Using the HDMI-to-DVI-D cable provided, connect the HDMI port on the TWR-MPC5125 to a DVI-D port on a display monitor. (Alternatively, connect the HDMI port to an HDMI port on a monitor. Cable not provided.)
Note: DVI –to–VGA is not supported.

NXP TWR-MPC5125 Tower System - Connect the HDMI cable

STEP 2
Connect the USB cable for the Serial-to-USB bridge to provide power
Power the board from a host computer by plugging in the dual-port USB cable. Insert the two Standard-A plugs into two USB ports a host computer. Then insert the Mini-B side of the cable into the Mini-B connector (J19) which is next to the SDHC card slot.
(Alternatively, the board can be powered by a 5V barrel jack from a wall supply. The supply must be a center-hot configuration 2.1 mm jack and the voltage must be 5V. Cable not provided).

NXP TWR-MPC5125 Tower System - Connect the USB cable

STEP 3
View video on the display
The board comes pre-programmed to automatically boot the LimePC™ Linux operating system with video demonstration application. Stop Here or Continue on to LimeOS™ Linux desktop

STEP 4
Connect a USB mouse and keyboard
Connect a USB mouse and USB keyboard to a USB hub and connect the hub to the Mini-AB connector (DOWN4) which is next to the RJ45 port.

NXP TWR-MPC5125 Tower System - Connect a USB mouse

STEP 5
Press Q on the keyboard or right-click on the mouse
The video demonstration application will close, revealing the LimeOS graphical desktop. Explore with the USB mouse and keyboard input.

STEP 6
Using the Serial-to- USB bridge
The Freescale MC9S08JM60 Serial to-USB bridge solution provides a RS-232 equivalent connection to the host computer through the USB communications device class. When plugged in and powered the USB connection will enumerate as a COM port on the PC.

NXP TWR-MPC5125 Tower System - device 1

To determine the COM port # for the connection, right click on the My Computer icon and select “Manage,” click Device Manager, find and expand ports (COM and LPT).

STEP 7
Install software driver
When the cable is plugged in the first time, the Found New Hardware Wizard will start. Select the option Install from a list or specific location (Advanced), then select “Next.”
Browse for the file Freescale_CDC_Driver. inf which is available on the DVD. Select “Next,” then “Finish.”

NXP TWR-MPC5125 Tower System - device 2

STEP 8
Open Microsoft® HyperTerminal or a terminal program of your choice
Select File > New Connection. Type a name for the new connection. Pick the COM port number for the connection found in step 4.
Choose the following port settings: Bits per Second: 115200, Data bits: 8, Parity: None, Stop bit: 1, Flow control: None.

NXP TWR-MPC5125 Tower System - device 3

STEP 9
Press the reset button on the board

NXP TWR-MPC5125 Tower System - device 4

STEP 10
Find the U-Boot prompt on the terminal
Quickly press a key (on the host computer keyboard) to stop automatic booting. The U-Boot bootloader is pre-flashed in the on-board NAND flash memory. At system start up, U-Boot initializes the system and allows the user to choose an operating system to run.
Note: The default operating system that automatically boots is LimeOS. To select another operating system such as MQX, press a key within three seconds to stop automatic booting (autoboot).

NXP TWR-MPC5125 Tower System - device 5

STEP 11
Booting Freescale MQX RTOS with digital sign demo application
At the U-Boot prompt, type “run mqx boot”. The MQX RTOS with demo application loads into the SDRAM from the NAND flash and executes.

NXP TWR-MPC5125 Tower System - Symbol 1

STEP 12
View images on the display
The Freescale MQX RTOS with digital signage demonstration software is preloaded on the board. This example application shows how information, advertising or other messages can be displayed on screens in retail stores, corporate  buildings and other public places.
To make this the auto-boot option, type “set bootcmd run mqxboot” and press “Enter.” Then type “save” to save this change to the U-Boot environment variables in the nand flash.

NXP TWR-MPC5125 Tower System - Symbol 2

To change back to autoboot Linux, replace “mqx boot” with “nand boot.”
STEP 13
Booting LimeOS Linux from the U-Boot terminal
Press the Reset button and type “run nandboot” at the U-Boot prompt
For more information, view the following documents:

  • MQX Lab: How to build and load MQX applications
  • Linux Lab: How to run pre-loaded applications in the LimeOS Linux demonstration software
  • TWR-MPC5125 User’s Manual: Hardware configuration, U-Boot and Linux information
  • MPC5125 Reference Manual and Data Sheet: MPC5125 information

For more information about other mobile GT families, visit www.freescale.com/mobil egt to get the latest lab tutorials, application notes, other supporting documents and learn about other training opportunities.
For more information on Tower System controllers and peripheral modules, visit www.freescale.com/tower. To become a member of the online Tower Geeks community, visit www.towergeeks.org.

Learn more at www.freescale.com/tower.
Freescale, the Freescale logo, mobileGT and MQX are trademarks of Freescale Semiconductor, Inc., Reg. U.S. Pat. & Tm. Off.
All other product or service names are the property of their respective owners. © 2010 Freescale Semiconductor, Inc.
Doc Number: MPC512CYMNQSG / REV 0
Agile Number: 926-78413 / REV A

Downloaded from Arrow.com.

NXP logo 2

Documents / Resources

NXP TWR-MPC5125 Tower System [pdf] Owner's Manual
MPC512CYMNQSG, TWR-MPC5125 Tower System, TWR-MPC5125, Tower System, System

References

Leave a comment

Your email address will not be published. Required fields are marked *