Newair NCH1K5BK00 1500 Count Built-In Cigar Humidor How to operate your cigar humidor Let your cigar humidor sit…
Before use, please read and follow all safety rules and operating instructions in this manual.
WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS SHOULD BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND HARM TO THE USER AND/OR PROPERTY.
Risk of child entrapment!
Keep children away from cigar humidors in use. Lock the door to your appliance and warn children not to play inside of it.
Childproof old humidors and other appliances you plan to discard or leave in storage by removing the door completely with a screwdriver.
R600a WARNINGS
For your safety observe the following recommendations:
Allow 24 hours before switching on the cigar humidor. During this time, we recommend that you leave the door open to clear any residual odors.
Recommendations
The location you have selected for your cigar humidor should:
Grounding Instructions
The cigar humidor must be grounded in case of wire leakage. Grounding reduces the risk of electrical shock. The cigar humidor is equipped with a power cord having a grounding wire and plug. The cigar humidor plug must be plugged into a properly affixed and grounded electrical outlet.
Improper use of the grounding plug can result in the risk of electric shock. Consult a qualified electrician or service person if the grounding instructions are not completely understood.
If the supply cord is damaged, it must be replaced by a qualified person in order to avoid an electrical hazard.
Unpack and remove all the protection and adhesive strips from the packaging around and inside the cigar humidor.
The cigar humidor must be positioned such that the plug is accessible. The cigar humidor should be installed in a suitable place where the compressor will not be subject to physical contact.
Leveling Your Cigar Humidor
The cigar humidor must be leveled BEFORE loading your cigars.
Your cigar humidor is equipped with 4 adjustable feet to facilitate easy leveling. It is recommended that you tighten the back feet to the maximum and adjust the front feet to level the cigar humidor.
Installing the Front Grill
The front grill must be installed before you build your cigar humidor into a cabinet.
Wash the interior of the humidor with a mild detergent and warm water. Make sure to not get the wood wet. Leave the door open and allow it to air dry thoroughly. If a “plastic” smell persists, place a dish of baking soda in the unit or stuff the humidor with newspapers overnight. When finished, let the unit run a full day to complete the airing out process.
If the supply cord is damaged, it must be replaced by a qualified person in order to avoid an electrical hazard.
It is recommended that you setup the cigar cabinet in a place where the ambient temperature is between 50 – 77°F. If the ambient temperature is above or below recommended temperatures, the performance of the unit may be affected. For example, placing in extreme cold or hot conditions may cause the interior temperature to fluctuate or not reach the appliance’s range.
The temperature may fluctuate depending on whether the interior light is on or off or how cigars are placed on the upper, middle, or lower section.
SEASONING YOUR CIGAR HUMIDOR
It is best to season your wood shelves and drawers before adding your cigars so that the wood is at an ideal relative humidity (RH) and does not absorb humidity from your cigars. To season your new cigar humidor:
Plug in and switch on the appliance by pressing on the power button for 3 seconds.
When you use the cigar humidor for the first time (or restart the cigar humidor after having it shut off for a long time), there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout. This is normal and it is due to the length of the activation time. Once the cigar humidor is running for a few hours everything will stabilize.
IMPORTANT: If the unit is unplugged, power is lost or turned off, wait 3 to 5 minutes before restarting the unit. The cigar humidor will not start if you attempt to restart before this time delay.
Operating Noises
To reach the desired temperature settings, our cigar humidor, like all cigar humidors operating with compressors and fans, may produce the following types of noises. These noises are normal and may occur as follows:
CIGAR STORAGE GUIDE
The cigar humidor has an automatic humidification system that is located at the bottom of the cabinet and the water- filling box is in the lower left side of the humidor. Open the plastic cover of the drawer to add water as shown below.
Notes:
Your cigar humidor comes with an auto-cycle defrost system. This system will only self-activate if the internal temperature of the humidor falls lower than 53F for extend periods of time.
If frost build up occurs, the defrost function will melt the frost and collect it in a tray located at the back of the cigar humidor next to the compressor where the compressor’s heat will evaporate the water and recycle it into the humidor’s humidification system.
This system, when self-activated, helps maintain the humidity level inside your cigar humidor by adding moisture back into the cigar cabinet.
NOTE: This cigar humidor is equipped with a double-glazed glass door that has a third internal acrylic layer to minimize condensation on the glass door.
HOW TO INSTALL THE DOOR HANDLE
CLEANING YOUR CIGAR CABINET
To clean your cigar cabinet:
HOW TO DISPOSE OF YOUR HUMIDOR
Correct Disposal of This Product
This symbol on the product, or in its packaging, indicates that this product may not be treated as household waste. Instead, it should be taken to the appropriate waste collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by the inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council., your household waste disposal service, or the shop where you purchased the product.
OPERATION MALFUNCTIONS
If your cigar humidor appears to be malfunctioning, unplug it and contact our customer service team. Any intervention on the cold circuit should be performed by a refrigeration technician who should carry out an inspection of the circuit sealing system. Similarly, any intervention on the electrical circuit should be performed by a qualified electrician.
WARNING: Any intervention performed by a non-authorized technician will lead to the warranty being void.
POWER FAILURES
In the event of a power interruption, all previous temperature settings are automatically reinstated, and it will revert to a preset temperature setting.
Most power failures are corrected within a short period of time. An hour or two loss of power will not affect cigar humidor’s temperatures. To avoid sudden change of temperature while the power is off, you should avoid opening the door. For longer periods of power failure, take steps to protect your cigars.
You can resolve most common usage problems easily by reviewing and following the troubleshooting information below.
Problem | Possible Causes | Solution |
The humidor will not operate. | The unit may be plugged in using a different voltage. | Check if using the wrong voltage. |
The circuit breaker may be tripped or there is a blown fuse. | Reset the circuit breaker or check for a broken fuse. | |
The humidor is not cold enough. | The external environment may require a higher setting. | Lower the temperature of the humidor. |
The door may be opened too frequently. | Open the door less frequently. | |
The door is not closed completely. | Make sure the door is closed securely. | |
The door seal does not seal properly. | Replace the seal on the door. Replacements can be acquired from the Newair customer support department. | |
The humidor does not have sufficient clearance. | Make sure there is at least 5 inches clearance between the back of the unit and any adjacent walls. | |
The light does not work. | There may be a problem with the display board. | Contact the Newair customer support department. |
The humidor vibrates while operating. | The unit is not sitting on a level floor, or the unit’s feet are not correctly installed. | Make sure the unit’s feet are in the proper position and tightened securely. |
Problem | Possible Causes | Solution |
The humidor produces a lot of noise. | The unit is not leveled. | See above. |
Check the fan. | Check the fan to make sure there is no debris or obstruction. If not, contact the Newair Customer Support Department. | |
Left window shows HH “High Temperature”. | Ambient temperature is too high. | Avoid using at ambient temperature above 108 degrees Fahrenheit. |
Leakage in refrigeration system or failure of indoor fan. | Contact a qualified technician for repairing. | |
Left window shows LL “Low Temperature”. | Ambient temperature is too low. | Avoid using at ambient temperature below 32 degrees Fahrenheit. |
Refrigeration system failure. | Contact a qualified technician for repairing. | |
Right window shows HH “High Humidity”. | Appliance is in a high humidity environment and shows higher than set humidity by 15% for more than 48 hrs. | If there is water in the water box it must be drained at this time. |
Refrigeration system failure. | Contact a qualified technician for repairing. | |
Right window shows LL “Low Humidity”. | Humidity is lower than set humidity by 15% for more than 48 hrs. There might be no water in the water box. | Add water to the water box. |
Refrigeration system failure. | Contact a qualified technician for repairing. |
This appliance is covered by a limited manufacturer’s warranty. For one year from the original date of purchase, the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship, provided the appliance has been used under normal operating conditions as intended by the manufacturer.
Warranty Terms
During the first year, any components of this appliance found to be defective due to materials or workmanship will be repaired or replaced, at the manufacturer’s discretion, at no charge to the original purchaser. The purchaser will be responsible for any removal or transportation costs.
Warranty Exclusions
The warranty will not apply if damage is caused by any of the following:
Obtaining Service
When making a warranty claim, please have the original bill of purchase with the purchase date available. Once confirmed that your appliance is eligible for warranty service, all repairs will be performed by a Newair authorized repair facility. The purchaser will be responsible for any removal or transportation costs. Replacement parts and/or units will be new, re-manufactured or refurbished and is subject to the manufacturer’s discretion. For technical support and warranty service, please email support@newairusa.com.
Newair NCH1K5BK00 1500 Count Cigar Humidor [pdf] User Manual NCH1K5BK00, 1500 Count Cigar Humidor, Count Cigar Humidor, Cigar Humidor, Humidor |
BBTINST-0414 Back and Bottom Connect Thermometer REOTEMP INSTRUMENT CORPORATION Installation and Use Procedure, Back &…
922194627V10 FAST Bin System FAST Bin User Manual Contents Trademark Information............................................................................................................................... 2 Support Information ...................................................................................................................................…
2522809 E0217 Thermometer Bedienungsanleitung Thermometer E0217 Best.-Nr. 2522809 Bestimmungsgemäße Verwendung Das Produkt dient zur Messung…
Reazeal RZ-003 Rechargeable Eyebrow Hair Remover Trimmer Specification Recommended Uses For Product Nose, Hair Remover,…
43242399 Wireless 5W Charging Pad Wireless 5W Charging Pad User Manual 43242399 Features Charge for…
DT14 SERIES Double Conveyor Oven ® DOUBLE CON® VEYOR TOASTER MODEL DT14 SERIES Installation and…