3-in-1 Portable Air Conditioner
OWNER’S MANUAL
MODEL NO. | NAC08KWH00 |
VOLTAGE: | 120V~ |
FREQUENCY: | 60Hz |
POWER: | 900W |
DIMENSIONS: | Width: 14.7 in Depth: 13.5 in Height: 26.9 in Weight: 46.3 lbs. |
COOLING AREA: | 200 sq. ft. |
BTU RATING: | 7,500 (ASHRAE) |
Register Your NewAir Product Online Today!
Take advantage of all the benefits product registration has to offer:
Service and Support Diagnose troubleshooting and service issues faster and more accurately | |
Recall Notifications Stay up to date on safety, system updates, and recall notifications | |
Special Promotions Opt-in for Newair promotions and offers |
Registering your product information online is safe & secure and takes less than 2 minutes to complete:
Alternatively, we recommend you attach a copy of your sales receipt below and record the following information, located on the manufacturer’s nameplate on the rear of the unit. You will need this information if it becomes necessary to contact the manufacturer for service inquiries.
Date of Purchase: _______________________
Serial Number: _________________________
Model Number: ________________________
SAFETY PRECAUTIONS
Please read the Manual carefully before operating the machine:
Special warning:
Power
1. Carrying Handle 2. Control Panel 3. Adjustable Front Grille 4. Casters 5. Exhaust Output | 6. Air Intake 7. Moisture Drain Plug 8. Remote Control 9. Exhaust Duct 10. Window Sealing Plate |
CONTROL PANEL AND REMOTE CONTROL
ERROR DETECTION
This unit has built-in error detection. If you see an error code shown on the screen (E1, E2, E4) please contact customer service and notify them of which code your unit is showing. If the code is E1 or E2, you will need your unit repaired professionally, as the temperature sensor is likely damaged. E4 means the internal temperature of the unit is too low, so the A/C will be shut off until the unit warms up again. If you see the E4 code, please turn off the unit and wait at least one hour before attempting to use it again.
Insert the exhaust hose into the window sealing plate, and adjust the opening of the window so that the sealing plate fits in the window properly. (Note that the length of the sealing plate is adjustable)
This exhaust duct is designed specifically for this unit. Do not replace it or attempt to modify it, as it may cause the unit to malfunction.
DRAINING THE WATER TANK
This unit is equipped with an automatic water vaporization system. The condenser is cooled through the circulation of condensing water to improve cooling efficiency and energy conservation.
If the tank is full, “FL” will appear on the display to indicate that it needs to be drained. Turn off the unit, remove the drain plug on the bottom of the back of the unit, and drain the tank until empty. Replace the plug and turn the unit back on to resume use.
Notice: To avoid electric shock, please turn off and unplug the unit before maintenance or repair.
CLEANING
DUST FILTER
SEASONAL CLEANING
If you are planning on putting the unit away long-term:
TROUBLESHOOTING
In case of any of the following problems, please contact a Newair™ authorized repair facility.
ISSUE | CAUSE | SOLUTION |
The A/C doesn’t work | The unit is not plugged in | Plug the unit in |
The display panel displays “FL” | Restart the A/C after powering off and draining, then it will return to normal | |
The timer was set, and the unit shut off | Restart the unit 3 minutes after it automatically shuts off | |
The A/C starts up too frequently | The unit is in direct sunlight | Move the unit out of direct sunlight |
Too many doors/windows are open; a heat source is affecting the unit | Close doors and windows, remove any heat sources placed too close to the A/C | |
The dust filter is dirty | Clean the dust filter | |
Air intake or exhaust output is clogged | Remove the exhaust tube and check for any blockage | |
The unit is making too much noise | The unit isn’t placed on a level surface | Place it on even and firm ground, avoid shaking |
Notice: For any issues not listed here that arise while using the A/C, turn the unit off and unplug it, wait a few minutes, and try again. If problems persist, contact customer service.
This appliance is covered by a limited manufacturer’s warranty. For one year from the original date of purchase, the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship, provided the appliance has been used under normal operating conditions as intended by the manufacturer.
Warranty Terms:
During the first year, any components of this appliance found to be defective due to materials or workmanship will be repaired or replaced, at the manufacturer’s discretion, at no charge to the original purchaser. The purchaser will be responsible for any removal or transportation costs.
Warranty Exclusions:
Obtaining Service:
When making a warranty claim, please have the original bill of purchase with the purchase date available. Once confirmed that your appliance is eligible for warranty service, all repairs will be performed by a Newair™ authorized repair facility. The purchaser will be responsible for any removal or transportation costs. Replacement parts and/or units will be new, re-manufactured, or refurbished and is subject to the manufacturer’s discretion. For technical support and warranty service, please email support@newairusa.com.
newair NAC08KWH00 3-in-1 Portable Air Conditioner [pdf] Owner's Manual NAC08KWH00, 3-in-1 Portable Air Conditioner, Portable Air Conditioner, Air Conditioner, NAC08KWH00, Conditioner |
DeLonghi ETAM29.66X CAPPUCCINO MACHINE User Manual
F750 Adventure LED Flashlight English PNI Adventure F750 LED flashlight Technical specifications · LED: 1…
BP A150 AFIB Automatic Blood Pressure Monitor Microlife AG Espenstrasse 139 9443 Widnau / Switzerland…
100W-200W 120-277V LED Vsolutions Highbay VENTURE LIGHTING'S LED VSOLUTIONS HIGHBAY 100W-200W 120-277V USER MANUAL Before…
A-D Phono Box S Analog to Digital Phono Preamp INSTRUCTIONS FOR USE Pro-Ject A/D Phono…
Si-RM13 Combined Manifold with Smart Wireless Probes Inc Temp Clamps Si-RM13 SIMPLIFIED USER MANUAL SAFETY…