Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of the Legrand Watt Stopper LMDW-102-W DLM Dual-Tech Digital 2-Button Occupancy Sensor. This device is designed to automatically control lighting based on occupancy detection, utilizing both Passive Infrared (PIR) and Ultrasonic technologies for enhanced accuracy. It features a 2-button interface and is programmable via an infrared remote.
Identifikatur tal-Prodott: 0210023292
Karatteristiċi tal-Prodott
- DLM System 2-Button Switch
- 24VDC RJ45 Connection
- Dual-Tech (PIR & Ultrasonic) Occupancy Detection
- Infrared Remote Programmable
- Temm abjad
Informazzjoni dwar is-Sigurtà
Please read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or property damage. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.
- TWISSIJA: Itfi l-enerġija mis-circuit breaker jew mill-kaxxa tal-fjużijiet qabel l-installazzjoni jew is-servizz.
- Dan l-apparat huwa ddisinjat għal Użu fuq ġewwa BISS.
- Do not install in wet locations or where exposed to extreme temperatures.
- Kun żgur li l-konnessjonijiet kollha huma siguri u iżolati kif suppost.
Setup u Installazzjoni
The LMDW-102-W sensor is designed for wall-mount installation and connects via a 24VDC RJ45 connection as part of a Digital Lighting Management (DLM) system.
- Skonnettjar tal-Enerġija: Before beginning installation, ensure that power to the circuit is turned off at the main service panel.
- Immuntar: Mount the sensor in a standard wall box. Ensure the mounting plate is securely fastened to the wall box.
- Wiring: Connect the RJ45 cable from the DLM system to the RJ45 port on the back of the sensor. Ensure the connection is firm. This device operates on 24VDC.
- Orjentazzjoni tas-Sensor: Position the sensor to ensure optimal coverage of the desired area. Avoid obstructions that might block the sensor's view.
- Apparat Sikur: Once wired, carefully push the device into the wall box and secure it with the provided screws. Attach the wall plate (not included) if applicable.
- Restawr tal-Enerġija: Restore power at the circuit breaker. The sensor will perform a self-test.

Istruzzjonijiet Operattivi
The LMDW-102-W sensor provides both automatic occupancy detection and manual control via its two push buttons.
Automatic Operation (Occupancy Detection)
The sensor uses both Passive Infrared (PIR) and Ultrasonic technologies to detect occupancy. When motion is detected, connected lights will turn on automatically. After a period of no detected occupancy (determined by system settings), the lights will turn off automatically.
Kontroll Manwali
The two buttons on the sensor allow for manual override of the automatic control:
- Buttuna ta' Fuq: Typically used to manually turn lights ON or to increase light levels.
- Buttuna tal-qiegħ: Typically used to manually turn lights OFF or to decrease light levels.
The exact function of these buttons can be programmed using an infrared remote control (sold separately) to suit specific application requirements within the DLM system.
Infrared Remote Programming
The sensor's settings, such as sensitivity, time delay, and button functions, can be adjusted using a compatible Legrand Watt Stopper infrared remote control. Refer to the remote control's manual for specific programming instructions.
Manutenzjoni
The LMDW-102-W sensor requires minimal maintenance to ensure optimal performance.
- Tindif: Periodically wipe the sensor lens and housing with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the device.
- Spezzjoni: Regularly inspect the sensor for any physical damage or loose connections.
- Ostruzzjonijiet: Ensure that the sensor's detection area remains clear of obstructions (e.g., furniture, tall plants) that could block its view and affect performance.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Lights do not turn on automatically. | No motion detected; power off; incorrect wiring; sensor obstructed; sensitivity too low. | Verify motion in detection area; check circuit breaker; inspect wiring; clear obstructions; adjust sensor sensitivity via remote. |
| Lights remain on. | Constant motion detected; time delay set too long; sensor faulty. | Ensure no constant motion; adjust time delay via remote; contact support if issue persists. |
| Id-dwal jintfew malajr wisq. | Time delay set too short; sensor sensitivity too low; sensor obstructed. | Adjust time delay via remote; increase sensor sensitivity; clear obstructions. |
| Manual buttons do not respond. | No power; incorrect programming; button malfunction. | Check power; verify programming with remote; contact support. |
Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Mudell | LMDW-102-W |
| Brand | Legrand (Wattstopper) |
| Mod ta' Operazzjoni | Manual / Automatic (Occupancy) |
| Vol Operattivtage | 24 VDC |
| Teknoloġija ta 'Sejbien | Dual-Tech (PIR & Ultrasonic) |
| Tip ta' Konnettur | RJ45 (for DLM System) |
| Tip ta' Swiċċ | Push Button (2-way circuit) |
| Metodu ta' Kontroll | Remote (Infrared) |
| Tip ta 'Immuntar | Mount Wall |
| Kulur | Abjad |
| Materjal | Stainless Steel (Contact Material) |
| Dimensjonijiet tal-oġġett (L x W x H) | 5 x 2 x 2 pulzieri |
| Piż tal-oġġett | 0.3 Liri |
| Klassifikazzjoni tal-Protezzjoni Internazzjonali | IP54 |
| Speċifikazzjoni Met | RoHS |
Garanzija u Appoġġ
For warranty information and technical support, please refer to the official Legrand Watt Stopper webis-sit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom. Żomm l-irċevuta tax-xiri tiegħek għal talbiet ta’ garanzija.
Riżorsi onlajn: Legrand Watt Stopper Official Websit