Red Lion PAXI0020

Red Lion Controls PAXI0020 Pax Counter/Rate Meter User Manual

Model: PAXI0020

1. Pengenalan

This manual provides essential information for the safe and efficient operation, installation, and maintenance of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter. Please read this manual thoroughly before installing or operating the device. Retain this manual for future reference.

2. Maklumat Keselamatan

AMARAN: Improper installation or operation can result in personal injury or damage to the equipment. Always follow local and national electrical codes.

  • Disconnect all power before installing or servicing the unit.
  • Pastikan pembumian yang betul untuk mengelakkan kejutan elektrik.
  • Jangan kendalikan peranti ini dalam persekitaran yang melebihi kadar suhu dan kelembapan yang ditetapkan.
  • Hanya kakitangan yang berkelayakan harus melakukan pemasangan dan penyelenggaraan.
  • Sahkan semua sambungan pendawaian adalah selamat dan betul sebelum menggunakan kuasa.

3. Produk Lebihview

The Red Lion Controls PAXI0020 is an AC-powered industrial counter and rate meter designed for precise measurement and display in various applications. It features a bright, easy-to-read display and intuitive front-panel controls for configuration and operation.

Front panel of the Red Lion Controls PAXI0020 Pax Counter/Rate Meter, showing a red digital display with the number 125005 and five control buttons labeled DSP, PAR, F1, F2, and RST.

This image displays the front face of the PAXI0020 unit. It features a large, red seven-segment LED display at the top, currently showing '125005'. Below the display are five push-buttons: 'DSP' (Display), 'PAR' (Parameter), 'F1' (Function 1), 'F2' (Function 2), and 'RST' (Reset). These buttons are used for navigating menus, adjusting settings, and controlling the meter's functions.

Komponen Panel Depan:

  • paparan: High-visibility red LED display for showing count, rate, and parameter values.
  • Butang DSP: Used to cycle through various display modes or views.
  • PAR Button: Accesses the parameter menu for configuration and setup.
  • F1 Button: Function key 1, typically user-programmable or for specific menu navigation.
  • F2 Button: Function key 2, typically user-programmable or for specific menu navigation.
  • Butang RST: Resets the counter or clears error states.

4. Persediaan

4.1. Pemasangan

The PAXI0020 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals. Cut a panel opening according to the dimensions provided in the product's technical specifications sheet (not included in this manual). Secure the unit using the provided mounting hardware.

4.2. Pendawaian

PERHATIAN: Ensure power is disconnected before making any wiring connections.

  • Bekalan Kuasa: Connect the AC power supply to the designated terminals. Refer to the product label for specific voltage keperluan.
  • Isyarat Input: Connect your counting or rate input signals (e.g., from sensors, encoders) to the appropriate input terminals. Pay close attention to polarity and signal type (e.g., NPN, PNP).
  • Sambungan Keluaran: If using control outputs, connect them to your external devices (e.g., relays, PLCs) as required by your application.
  • Pembumian: Ensure the unit is properly grounded to a protective earth.

After all connections are made, double-check them for correctness and security before applying power.

5. Arahan Operasi

5.1. Hidupkan kuasa

Once properly wired, apply AC power to the unit. The display will illuminate, typically showing the current count or rate value.

5.2. Basic Display Modes (DSP Button)

Tekan ke DSP button to cycle through available display modes. These may include:

  • Current Count Value
  • Current Rate Value
  • Peak/Min Values
  • Totalized Count

5.3. Parameter Configuration (PAR Button)

Tekan dan tahan butang PAR button to enter the parameter setup menu. Use the F1 dan F2 buttons to navigate through parameters and adjust values. The DSP button may be used to confirm selections or move to the next digit/setting. Common parameters include:

  • Input type and scaling
  • Output functions and setpoints
  • Kedudukan titik perpuluhan
  • Paparkan kadar kemas kini
  • Tetapan keselamatan

Refer to the detailed programming guide (typically a separate document) for comprehensive parameter descriptions and configuration steps.

5.4. Resetting the Counter (RST Button)

Tekan ke RST button to reset the active counter to zero. The function of the RST button may be configurable in the parameter menu (e.g., local reset, remote reset, or disabled).

6. Penyelenggaraan

The PAXI0020 is designed for minimal maintenance. Regular inspection and cleaning are recommended.

  • Pembersihan: Gunakan yang lembut, damp cloth to clean the front panel. Do not use abrasive cleaners or solvents.
  • Pemeriksaan: Periodically check wiring connections for tightness and signs of wear or corrosion. Ensure the unit's ventilation is not obstructed.
  • Penentukuran: The unit is factory calibrated. If recalibration is suspected, contact Red Lion Controls support.

7. Penyelesaian masalah

If the PAXI0020 is not functioning as expected, review isu-isu lazim berikut:

  • Tiada Paparan/Tiada Kuasa:
    • Verify AC power supply is connected and active.
    • Check fuses (if applicable) in the power circuit.
    • Ensure wiring connections are secure.
  • Incorrect Count/Rate:
    • Check input signal wiring and sensor operation.
    • Verify input scaling and parameter settings in the PAR menu.
    • Ensure the correct input type (e.g., NPN, PNP) is selected.
  • Ralat Paparan:
    • Consult the product's full technical manual for a list of error codes and their meanings.
    • Try cycling power to the unit.
  • Butang Tidak Responsif:
    • Ensure the unit is not in a locked mode (check security settings in PAR menu).
    • Kitaran kuasa ke unit.

If problems persist, contact Red Lion Controls technical support.

8. Spesifikasi

SpesifikasiNilai
ModelPAXI0020
PengeluarKawalan Singa Merah
Input KuasaAC (Specific voltage range typically on product label)
Berat Barang22 paun
ASINB07CYPVM83
Tarikh Mula-mula Tersedia8 Mei 2018

9. Waranti dan Sokongan

Warranty information for the Red Lion Controls PAXI0020 is typically provided with the product at the time of purchase or can be obtained directly from Red Lion Controls. For technical assistance, product documentation, or warranty claims, please contact Red Lion Controls customer support.

You can also visit the official Red Lion store for more information: Red Lion Store on Amazon

© 2023 Red Lion Controls. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.