Instruction Manual for PHILIPS models including: BY010P LED16-730, BY010P LED16-740, BY010P LED16-765, BY010P LED36-730, BY010P LED36-740, BY010P LED36-765, BY010P SmartBright Solar Lowbay, BY010P, SmartBright Solar Lowbay, Solar Lowbay, Lowbay

6.3.1.2.6.609 说明书 飞利浦 lowbay 太阳能 6.28

LIU JESSE

Install instructions pdf 4.6 MB

SmartBright Solar Lowbay | BY010P | Philips lighting

SmartBright Solar Lowbay

31 lug 2024 — The setting default of this luminaire is AUTO: Automatic Sensor Dimming Mode. 2. Press the or button to turn on the constant lighting mode at day time or at ...

PDF preview unavailable. Download the PDF instead.

SmartBright Solar Lowbay
SmartBright Solar Lowbay
BY010P Mounting instruction

IP44
for luminaire

Type Number

Flux(lm)

Battery type

Battery parameter

PV parameter

Remote type

BY010P LED16/730 Solar BY010P LED16/740 Solar BY010P LED16/765 Solar

1600lm

Lithium iron phosphate

12.8V/3.3AH

15W/15V

Infrared

BY010P LED36/730 Solar BY010P LED36/740 Solar BY010P LED36/765 Solar

3600lm

Lithium iron phosphate

9.6V/9.9AH 32W/15V

Infrared

Sensor type
Infrared Infrared

CCT

Working temperature

3000K 4000K 6500K

0-50

3000K 4000K 6500K

0-50

Weight 2.33Kg 4.37Kg

L1 L

D L2
H

Unit: mm

W1

H1

TYPE

D

L

L1

L2

H

1600lm 273

450

300

150

155

3600lm 344

450

300

150

170

d a×b L4

-60°~ 60°

TYPE W1 L3 L4 d axb H1 L5 1600lm 350 350 180 8.5 15x8.5 15 4800 3600lm 350 680 180 8.5 15x8.5 15 4800

L3 L5 6.2

1

M5 Screw Torque 3.2Nm

M6 Screw Torque 10Nm

M6 Screw Torque 3.2Nm

3

Support extension cable connection, need to order separately.

911401886302 911401886402

PV extension cable 3M for BY010P
PV extension cable 5M for BY010P

2
PV panel input cable

DC24V input cable
Loosen the screw, rotate the hook to the 90°, tighten the screw before the installation.
M4 Screw Torque 0.6~0.8Nm

4

b

a

Cable connection for external DC24V charger

2x0.75 mm2

42

8

Red Black

SIGNIFY LUMINAIRES (SHANGHAI) CO.,LTD Address: 2F, Building 1, No. 2555 Hechuan Road, Minhang District, Shanghai, P.R. China Postal code: 200233
 25551 200233

Philips and the Philips shield emblem are registered trademarks of Koninklijke Philips N.V.

ON/OFF

H

M

AUTO

L

DIM

ON/OFF: Wake-up (ON)/Sleep (OFF), the luminaire turns on and keep the same working mode as last mode setting.
AUTO: Automatic Sensor Dimming Mode, the luminaire automatically turns on as PV panel detects the sunset. (Same as Mode M setting).
H: The luminaire automatically turns ON at 30% brightness as PV panel detects the sunset. If someone is detected, the brightness will be increased to 100% for 15 seconds. Turns off at battery low.
M: The luminaire automatically turns ON at 20% brightness as PV panel detects the sunset. If someone is detected, the brightness will be increased to 100% for 15 seconds. Turns off at battery low.
L: The luminaire automatically turns ON at 10% brightness as PV panel detects the sunset. If someone is detected, the brightness will be increased to 100% for 15 seconds. Turns off at battery low.
DIM: Time Control Dimming Mode, the luminaire automatically turns ON as PV panel detects the sunset, and the luminaire will keep running according to the time control dimming setting (20% brightness output in first 1 hour, 100% brightness output in 0.5 hour, 40% brightness output in 1 hour, 20% brightness output in 1.5 hour, 10% brightness output in 2 hours, 5% brightness output in 6 hours). Turns off at battery low. (The sensor function is disabled in DIM mode, and the lighting time is up to 12hours in the state of the full charged battery)

Constant lighting mode: Decrease the brightness every 10% each time by pressing this button, and the minimum brightness can keep 10%. (The light sensor and PIR sensor and time control function are all disabled in this mode)

Notes:

Constant lighting mode: Increase the brightness every 10% each time by pressing this button, and the maximum brightness can keep 100%. (The light sensor and PIR sensor and time control function are all disabled in this mode)

1. The setting default of this luminaire is AUTO: Automatic Sensor Dimming Mode.

2. Press the or button to turn on the constant lighting mode at day time or at night time.

3. In constant lighting mode, the luminaire turns off at battery low. And the luminaire will return to the dimming mode with memory function

after the battery power recharged.

4. In constant lighting mode, the light sensor and PIR sensor and time control function are all disabled in this mode. And the luminaire will

keep working at the setting brightness. Turns off at battery low.

5. LED indication on luminaire: solid red light (the state of charging), flashing red light (low battery capacity).

Sensor detective range:



h(m) d(m) d/2(m) 

h

4

6

3 120°

d

Not detected

Detected

Application NOTES:

1.Install the solar panel on open roof or wall facing towards Sun. The tilt angle can be adjusted. 2.There shall not be any light source over the solar panel at night, as it may interfere with the operations of the luminaire. 3.Charge the battery under Sunlight at least 8 hours before first use. 4.After installation, the working modes can be set by the infrared remote controller. 5.This luminaire works 100% on solar energy, and it also can be charged via the external DC24V charger. The charging power for 1600lm one must be higher than 20Watt, the charging power for 3600lm one must be higher than 35Watt. The voltage range for external DC24V charger can be DC22-26V. (In case wrong DC charger is used not matching mentioned specification, the product may get damaged and the warranty will be void.) 6.Detection of dark/dawn is based on lighting intensity falling on solar panel. 7.The battery capacity will be reduced when the ambient temperature is below zero degree Celsius. 8.When the battery low capacity (<30%), the brightness output will be dimmed to 15% brightness to extend the running time, and the luminaire turns off at battery low. 9.This product contains lithium batteries, it is important to note that if the battery is not used for a long period of time (>11 months), it may be in some state of over-discharge due to its self-discharge characteristics. Over-discharge may degrade battery performance, and the warranty shall be void. 10.Applications: Under Canopy/Backyard/Parking Shed/Warehouse/Amenity.Not to use in outdoor areas. 11.The light source and/or control gear and/or external flexible cable contained in this luminaire are not replaceable, in case of damage, please replace the luminaire. 12.Please inform yourself about the local waste disposal, separation and collection system for electrical and electronic products and packaging. Please act according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.

ON/OFF

H

M

AUTO

L

DIM

Notes: Sensor detective range:
Application NOTES:



h(m) d(m) d/2(m) 

h

4

6

3 120°

d


Adobe PDF library 15.00